Users Guide

9–iSER Configuration
Configuring iSER for SLES 12 and Later
192 AH0054602-00 M
Figure 9-4. Checking for New iSCSI Device
Configuring iSER for SLES 12 and Later
Because the targetcli is not inbox on SLES 12 and later, you must complete the
following procedure.
To configure iSER for SLES 12 and later:
1. Install targetcli.
For SLES 12:
Locate, copy and install the following RPMs from the ISO image (x86_64
and noarch location).
lio-utils-4.1-14.6.x86_64.rpm
python-configobj-4.7.2-18.10.noarch.rpm
python-PrettyTable-0.7.2-8.5.noarch.rpm
python-configshell-1.5-1.44.noarch.rpm
python-pyparsing-2.0.1-4.10.noarch.rpm
python-netifaces-0.8-6.55.x86_64.rpm
python-rtslib-2.2-6.6.noarch.rpm
python-urwid-1.1.1-6.144.x86_64.rpm
targetcli-2.1-3.8.x86_64.rpm
For SLES 15 and SLES 15 SP1:
Load the SLES Package DVD and install targetcli by issuing the following
Zypper command, which installs all the dependency packages:
# zypper install python3-targetcli-fb
2. Before starting the targetcli, load all RoCE device drivers and iSER modules
as follows:
# modprobe qed
# modprobe qede
# modprobe qedr
# modprobe ib_iser (initiator)
# modprobe ib_isert (target)