Owners Manual
Table 16. — Errors that soft halt your computer (continued)
Error Message
Alert! CPU 1 fan failure.
Alert! Memory related failure detected.
Alert! Correctable memory error has been detected in memory slot DIMMx.
Warning: Non-optimal memory population detected. For increased memory bandwidth populate DIMM connectors with white latches
before those with black latches.
Your current power supply does not support the recent configuration changes made to your system. Please contact Dell Technical
support team to learn about upgrading to a higher wattage power supply.
Dell Reliable Memory Technology (RMT) has discovered and isolated errors in system memory. You may continue to work. Memory
module replacement is recommended. Please refer to the RMT Event log screen in BIOS setup for specific DIMM information.
Dell Reliable Memory Technology (RMT) has discovered and isolated errors in system memory. You may continue to work. Additional
errors will not be isolated. Memory module replacement is recommended. Please refer to the RMT Event log screen in BIOS setup for
specific DIMM information.
50 Troubleshooting Your Computer