6. Insert the processor and carrier assembly into the heat sink so that the hooks on the four corners of the carrier are locked
into the openings of heat sink.
NOTE: After inserting the processor and carrier assembly into the heat sink, double check to see whether the triangle
on the carrier is located on the bottom right corner of the heat sink (when the bottom side of the heat sink is facing up).
7. Install the processor and heat sink onto the central processing unit (CPU) socket and then secure the four captive screws
on the heat sink to the system board in sequential order (1 > 2 > 3 > 4).
68
Removing and installing components