Processor heat sink module
Removing the processor heat sink module
1. Follow the procedure in Before working inside your computer.
NOTE: Ensure that you have Torx 30 screwdriver to remove the processor heat sink module (PHM).
2. Remove the:
a. side cover
b. air shroud
3. To remove the heat sink:
a. Remove the four heat sink screws [1], in the diagonal order (4, 3, 2, 1).
b. Lift the heat sink away from the CPU slot on the system board.
CAUTION: CPU will be removed with the heat sink.