Setup Guide
Table 17. Computer environment
Description Operating Storage
Temperature range
10°C–35°C (50°F–95°F) -40°C-65°C (-40°F-149°F)
Relative humidity (maximum)
20% to 85% (non-condensing) 5% to 95% (non-condensing)
Vibration (maximum)
*
0.52 GRMS random at 5 Hz to 350 Hz 2.0 GRMS random at 5 Hz to 350 Hz
Shock (maximum)
Bottom half-sine pulse with a change in
velocity of 50.8 cm/sec (20 in./sec)
105G half-sine pulse with a change in
velocity of 133 cm/sec (52.5 in./sec)
Altitude (maximum)
3048 m (10,000 ft) 10,668 m (35,000 ft)
* Measured using a random vibration spectrum that simulates user environment.
† Measured using a 2 ms half-sine pulse when the hard drive is in use.
Service and support
NOTE: For more details on Dell Service Plans, see https://www.dell.com/learn/us/en/19/services/warranty-support-
services.
Table 18. Warranty
Warranty
1 Year Basic Warranty with Hardware Service on site service after remote diagnosis
2 Years Basic Warranty Extension
3 Years Basic Warranty Extension
4 Years Basic Warranty Extension
5 Years Basic Warranty Extension
1 Year ProSupport and Next Business Day on-site service
2 Years ProSupport and Next Business Day on-site service
3 Years ProSupport and Next Business Day on-site service
4 Years ProSupport and Next Business Day on-site service
5 Years ProSupport and Next Business Day on-site service
1 Year ProSupport Plus for Client with Next Business Day on-site service
2 Years ProSupport Plus for Client with Next Business Day on-site service
3 Years ProSupport Plus for Client with Next Business Day on-site service
4 Years ProSupport Plus for Client with Next Business Day on-site service
5 Years ProSupport Plus for Client with Next Business Day on-site service
Table 19. Accidental damage services
Accidental Damage Services
1 Year Accidental Damage Service
2 Years Accidental Damage Service
3 Years Accidental Damage Service
4 Years Accidental Damage Service
Specifications of Precision 3440 Small Form Factor 21