Reference Guide
PowerVault ML6000 SCSI Reference Guide 73
04h 83h x The library is not ready due to aisle power being disabled
04h 8Dh x The library is not ready because it is offline
08h 00h x LU Communication Failure
08h 01h x
LU Communication – Timeout (only PowerVault ML6000)
08h 80h x LU Communication – SCSI Failure
08h 82h x LU Communication – SCSI Command Execution or Queuing
Failure
08h 83h x LU Communication – SCSI Command Failed
08h 84h x LU Communication – SCSI Time-Out
08h 85h x LU Communication – SCSI Autosense Failed
08h 86h x LU Communication – SCSI Aborted
08h 87h x LU Communication – SCSI Abort Failed
08h 88h x LU Communication – SCSI Status Failed
08h B0h x LU Communication – FC Data Underrun
08h B1h x LU Communication – FC DMA Error
08h B2h x LU Communication – FC Reset
08h B3h x LU Communication – FC Data Overrun
08h B4h x LU Communication – FC Queue Full
08h B5h x LU Communication – Port Unavailable
08h B6h x LU Communication - Port Logged Out
08h B7h x LU Communication - Port Configuration Changed
15h 01h x A mechanical positioning error occurred
1Ah 00h x Parameter list length error
1Bh 00h x Synchronous data transfer error
20h 00h x Illegal opcode in CDB
21h 01h x Invalid element address in CDB
24h 00h x Invalid field in CDB
25h 00h x Illegal LUN
26h 00h x Invalid field in Parameter List
26h 04h x Invalid release of persistent reservation
28h 00h x Not Ready to Ready change, door(s) opened and closed
Table 71 Additional Sense Codes and Qualifiers (Continued)
ASC ASCQ
Sense Keys
Description
2456B










