Owners Manual
Table Of Contents
- Dell EMC PowerVault MD3460 Storage Arrays Owner's Manual
- About your system
- Controller modules
- Installing and removing system components
- Troubleshooting your system
- Troubleshooting storage array startup failure
- Troubleshooting loss of communication
- Troubleshooting external connections
- Troubleshooting power supply modules
- Troubleshooting array cooling problems
- Troubleshooting expansion enclosure management modules
- Troubleshooting physical disks
- Troubleshooting array and expansion enclosure connections
- Troubleshooting a wet storage array
- Troubleshooting a damaged array
- Controller failure conditions
- Technical specifications
- Getting help
3. Turn off the host server, storage array, and expansion enclosures.
4. Reseat the RAID controller module and reconnect cables on the storage array and the host server.
5. Turn on the expansion arrays and then the storage array and wait until the system is fully booted.
6. Turn on the host server.
7. Check the LEDs of all cabled ports. Replace the fibre optic cables of any port(s) where both LEDs are unlit.
If the problem is not resolved, see Getting Help.
NOTE: You must turn off the host server before resetting the cables on the storage array or expansion enclosure.
8. Reboot the host server.
Troubleshooting a wet storage array
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by
your warranty. Read and follow the safety instructions that are shipped with your product.
1. Turn off the array and disconnect all the cables.
2. Remove the following components from the array:
● Physical disks
● RAID controller modules
● Power supply modules
● Cooling fan modules
3. Let the system dry thoroughly for at least 24 hours.
4. Reinstall the components you removed in step 2.
5. Connect all the cables and turn on the array.
Troubleshooting a damaged array
CAUTION:
Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by
your warranty. Read and follow the safety instructions that are shipped with your product.
1. Ensure that the following components are properly installed:
● Physical disks
● RAID controller modules
● Power supply modules
● Cooling fan module
2. Ensure that all the cables are properly connected and that there are no damaged pins in the connectors.
3. Run the diagnostics available in Dell EMC PowerVault Modular Disk (MD) Storage Manager.
4. In the AMW, select a component in the Hardware pane of the Hardware tab.
5. Select Hardware > RAID Controller Module > Advanced > Run Diagnostics > RAID Controller Module.
Controller failure conditions
Certain events can cause a RAID controller module to fail and/or shut down. Unrecoverable ECC memory or PCI errors, or
critical physical conditions can cause lockdown. If your RAID storage array is configured for redundant access and cache
mirroring, the surviving controller can normally recover without data loss or shutdown.
Troubleshooting your system
37