Deployment Guide

Post Installation Tasks
Before using the Dell PowerVault storage array for the first time, complete these initial configuration tasks in the order shown. These tasks
are performed using the MD Storage Manager.
1. For out-of-band management, you must set the network configuration for each RAID controller module, including its Internet Protocol
(IP) address, subnetwork mask (subnet mask), and gateway.
NOTE: You can set the network configuration using a DHCP server.
2. Launch MD Storage Manager.
Click Start > Programs > Dell > MD Storage Manager > Modular Disk Storage Manager Client on Microsoft Windows
operating systems.
Click the PowerVault MD Storage Manager desktop icon on Linux operating systems.
You can also launch PowerVault MD Storage Manager in Linux by running the following commands at the command prompt:
cd /opt/dell/mdstoragesoftware/mdstoragemanager/client./SMclient
3. Go to Setup > Add Storage Array and start the automatic discovery of systems in the Enterprise Management Window (EMW).
NOTE:
Only storage arrays configured with IP address on the same subnet as the management stations will be
detected.
NOTE: It may take several minutes for the discovery process to complete. Closing the Automatic Discovery Status
window before this stops the discovery process.
After discovery is complete, a confirmation screen is displayed.
4. Click Close.
Topics:
Verifying Storage Array Discovery
Initial Setup Tasks
Verifying Storage Array Discovery
The Automatic Discovery option automatically discovers both in-band and out-of-band arrays and adds the storage arrays to the
management domain. If the out-of-band or in-band connections shown on the summary page are not accurate, complete the following
steps. For more information, see the online Help.
1. Check the hardware and connections for possible problems.
For specific procedures on troubleshooting interface problems, see the Dell PowerVault MD Series Storage Arrays Owner's Manual at
Dell.com/powervaultmanuals.
2. Verify that the array is on the local subnetwork. If it is not, using MD Storage Manager, manually add the storage array to the subnet.
3. Verify that the status of each storage array is Optimal.
4. If an array shows an Unresponsive status, complete one of the following steps:
To remove the array from the management domain, select the array, right-click and click Remove > Storage Array.
To add an array, in the EMW, select Automatic Discovery.
NOTE: You can also add an array in the EMW using its known management ports IP addresses.
Initial Setup Tasks
1. The name of the first storage array found is displayed in the Devices tab of the EMW.
To see a list of all storage arrays found on the local network, expand Discovered Storage Arrays in the Devices tab of the EMW.
4
20 Post Installation Tasks