Users Guide
Setting the library to factory defaults
Select Configuration > Set Default to reset the library to the factory default settings. See Table 13 on
page 31. The date and time must be reset after restoring factory default settings. See “Configuring date
and time settings” on page 62.
Important: This configuration setting deletes all current library settings, and should be used with utmost
caution.
To restore your library configuration, see “Saving and restoring configuration settings” on page 89.
Servicing the library
The Service menu on the Operator Panel gives users access to troubleshooting and maintenance
diagnostic tools.
Checking the library error status
Select Service > View Error Status to check the status of the major library components.
Select the component to view its error status:
v Library - Checks the error status of the library.
v Drive - Checks the error status of the tape drive.
If an error occurs, press Enter to display specific error information. You can check the meaning of error
codes in Appendix A, “Error codes,” on page 121.
Running library verify diagnostic procedures
Select Service > Diagnostics > Run Library Verify to test the library and drive hardware,
communications, and the read or write capability of the library. Library Verify is the most critical and
most frequently used test, and is run after all maintenance procedures to ensure correct library
performance.
Configuration
SetDefault
Figure 71. Factory default settings
Service
ViewErrorStatus
ViewLibraryErrorStatus
ViewDriveErrorStatus
Figure 72. Error status menu
Service
Diagnostics
RunLibraryVerify
Figure 73. Run Library Verify command
Operations 65