Storage System Hardware Owner's Manual
Table Of Contents
- Hardware Owner’s Manual
- About Your System
- Using the System Setup Program
- Installing System Components
- Recommended Tools
- Inside the System
- Front Bezel
- Opening and Closing the System
- Hard Drives
- Replacing a Hard-Drive Carrier
- Power Supplies
- System Fans
- Cooling Shroud
- Fan Brackets
- Cable Routing
- SAS Controller Daughter Card
- Configuring the Boot Device
- Expansion Cards
- Expansion-Card Cage
- DRAC Card and Cables
- Optical Drive and Cable
- System Memory
- Activating the Integrated NIC TOE
- Processors
- System Battery
- Expansion-Card Riser Boards
- Sideplane Board
- SAS Backplane Board
- Control Panel Assembly (Service-only Procedure)
- System Board (Service-only Procedure)
- Troubleshooting Your System
- Safety First-For You and Your System
- Start-Up Routine
- Checking the Equipment
- Troubleshooting Basic I/O Functions
- Troubleshooting a NIC
- Troubleshooting a Wet System
- Troubleshooting a Damaged System
- Troubleshooting the System Battery
- Troubleshooting Power Supplies
- Troubleshooting System Cooling Problems
- Troubleshooting System Memory
- Troubleshooting an Optical Drive
- Troubleshooting an External SCSI Tape Drive
- Troubleshooting a Hard Drive
- Troubleshooting a SAS Controller Daughter Card
- Troubleshooting Expansion Cards
- Troubleshooting the Microprocessors
- Running the System Diagnostics
- Jumpers and Connectors
- Getting Help
- Glossary
- Index

About Your System 27
E1811 HDD ## Rbld
Abrt
The specified hard drive
has experienced a rebuild
abort.
See "Troubleshooting a
Hard Drive" on page 146.
If the problem persists, see
your RAID
documentation.
E1812 HDD ##
Removed
The specified hard drive
has been removed from
the system.
Information only.
E1913 CPU &
Firmware
Mismatch
The BMC firmware does
not support the CPU.
Update to the latest BMC
firmware. See the BMC
User’s Guide for more
information on setup and
use of BMC.
E1A11 PCI Rsr
Config
PCI risers are not
configured correctly; some
invalid configurations may
prevent the system from
powering on.
See "Expansion-Card Riser
Boards" on page 112.
E1A12 PCI Rsr
Missing
One or all of the PCI risers
is missing, preventing the
system from powering on.
Information only.
E1A14 SAS Cable A SAS cable A is missing or
bad.
Reseat the cable. If
problem persists, replace
cable. See "SAS Controller
Daughter Card" on
page 85.
E1A15 SAS Cable B SAS cable B is missing or
bad.
Reseat the cable. If
problem persists, replace
cable. See "SAS Controller
Daughter Card" on
page 85.
E2010 No Memory No memory is installed in
the system.
Install memory. See
"Installing Memory
Modules" on page 102.
Table 1-6. LCD Status Messages (continued)
Code Text Causes Corrective Actions
Book.book Page 27 Monday, September 14, 2009 12:57 PM