Display Sensor Status
Sensor Status displays the results of the real-time sensors on your library.
Path:
Displaying the Error Log
The Error Log provides a listing of errors that need to be addressed by the operator. The log can store up to 100 errors and is preserved through power
cycles. The log is accessible via the LCD as well as the SCSI interface, the serial port, and the RMU interface. You may be asked to supply log information to
Dell Technical Support for troubleshooting purposes if other problem resolution strategies do not work.
Path:
The format of the entries is:
l P: = Number of “puts”to a location.
l G: = Number of “gets”from a location.
Step 3 To exit, press to highlight and
then press .
You are returned to the Status menu.
Selection
Description/Result
Step 1 From the Status menu, highlight
and press .
Displays results of real-time sensors.
Step 2 Press and to view each sensor
status.
Available options are:
l Door (Media Access): opened or closed
l Picker: empty or full
l IE Slot: empty or full
l Magazine 1: installed or removed
l Magazine 2: installed or removed
l Rear Slots: represented by a nine
character string with "1"s and "-"s(-1-
1-1-1-) where 1 means slot full, and -
means slot empty.
Step 3 To exit, press to highlight and
then press .
You are returned to the Status menu.
Selection
Description/Result
Step 1 From the Status menu, highlight
and press .
Displays Error log.
Step 2 Press and to scroll through the
error messages.
The format of the entries is as follows:
0:00:00 = hours:minutes:seconds of power
on time since the error occurred .
SAC E2 E047 = Service Action Code of error
message.
For more information on error codes, see
Error Messages.