Manual
Export Media  
Export allows you to move a data or cleaning tape cartridge from the source slot you choose to the IE slot without opening the front door. If the IE slot is 
configured as a storage slot, you will not be able to export data cartridges. For more information on configuring the IE slot, see Configure IE Slot.  
You can use the Move Media command to export data cartridges when the IE slot is configured as a data slot. For more information, see Moving Media.  
Path: 
Export Data Cartridge 
Step 6 Press   and   to select the how 
many times the cleaning tape has been 
used.  
You will need to specify how many times this 
cartridge has been used, if any.  
Step 7 Press   to move to next field.  
 
Step 8 Press   and   to set the maximum 
number of times the cleaning tape can be 
used.  
l For SDLT-320 media, the maximum 
number of uses is 20.  
l You can specify a different number, if 
you wish to restrict the number of 
times this cleaning cartridge will be 
used.  
Step 9 Press   to highlight Run ( ) and 
then press  .  
The cleaning cartridge is imported to the first 
available cleaning slot.  
Step 10 A confirmation screen displays. 
Press   to dismiss.  
 
Selection  
Description/Result  
Step 1 Open the IE door and check the IE 
slot to make sure that it is empty. If a tape is 
present, remove it.  
 
Step 2 From the Command menu, highlight 
the icon with the arrow pointing to the top 
right corner   and press  .  
Exports media to IE slot.  
Step 3 Highlight the icon with the "D" in the 
top left corner   and press  .  
Exports a data cartridge.  
Step 4 Press   and   to select the slot 
you would like to export the media from.  
SRC = source  
 
In this example, the tape cartridge in slot 01 
is to be exported to the IE slot.  
Step 5 Press   to highlight Run ( ) and 
then press  .  
The specified data cartridge is exported to 
the IE slot.  
Step 6 A confirmation screen displays. Press 
to dismiss.  
 
Step 7 You can continue to export data 
 