Configuring SCSI and Fibre Parameters 
SCSI/Fibre allows you to set IDs for the library and drives, configure host access, and set emulation mode. If you have a fibre library, you can set the fibre loop 
ID, speed, and topology by means of this menu. 
Path: 
Set Drive SCSI IDs  
The SCSI IDs of the drives identifies which IDs the drives use to communicate with the host.  
Step 1 From the Setup menu, highlight   
and press  .  
Step 2 Press   and   to select IE.  
Configures IE slot.  
Step 3 Press   to move to the next field.  
 
Step 4 Press   and   to select 
configuration option.  
Available options are:  
l ST: appears as a valid storage location 
to the host application (host will see 
24 data slots for LTO or 21 for SDLT-
320).  
l IE: host will see one import/export slot 
and 23 data slots for LTO or 20 for 
SDLT-320. If partitioning is enabled, 
this slot must be configured "IE" and 
not "ST".  
Step 5 Press   to highlight Run ( ) and 
then press  .  
The IE slot is configured.  
Step 6 A confirmation screen displays. Press 
 to dismiss.  
 
Selection  
Description/Result  
 
Step 1 From the Setup menu, highlight   
and press  .  
 
Step 2 Highlight   and press  .  
Sets the drive SCSI IDs.  
Step 3 Press   and   to select the ID you 
would like to set for the Drive 1.  
You must choose a number between 0 and 
15. The default ID is 1.  
Step 4 If you have two drives installed, 
press   to highlight Drive 2.  
 
Step 5 Press   and   to select the ID you 
would like to set for the Drive 2.  
You must choose a number between 0 and 
15. Ensure that this ID is different from the 
ID you set for Drive 1. The default ID is 2.  