Setup Guide
4
Technical Specifications
This chapter lists the Z9100–ON specifications.
NOTE: Operate the system at an ambient temperature not higher than 113°F (45°C).
CAUTION: Lithium Battery Caution: To avoid the possibility of an explosion, always replace the
battery correctly.
NOTE: Replace the battery only with the same or an equivalent type. Dispose of the batteries
according to the manufacturer's instructions.
Table 3. Z9100–ON Chassis Physical Design
Parameter Specifications
Height 1.72 inches (44 mm)
Width 17.1 inches (434 mm)
Depth
Chassis: 18.2 inches (462 mm)
Handle: 1.57 inches (40 mm)
Chassis weight with factory-installed components 19 lbs (8.62 kg) (2*PSUs)
Rack clearance required
Front: 5 inches (12.7 cm)
Back: 5 inches (12.7 cm)
Table 4. Environmental Parameters
Parameter Specifications
Operating temperature 32° to 113°F (0° to 45°C)
NOTE: Reduce maximum temperature by
1°C/300 meters (1°F/547 feet) above 950
meters (3,117 feet).
Operating humidity 5 to 90 percent (RH), noncondensing
Storage temperature –40° to 158°F (–40° to 70°C)
Storage and non-operating humidity 5 to 95 percent (RH), noncondensing
Maximum thermal output 1153.265 BTH/hr
Maximum operational altitude 10,000 feet (3,048 meters)
Maximum non-operational altitude 39,370 feet (12,000 meters)
Shock Meets Bellcore Zone 4 earthquake requirements
(MIL-STD-810)
Technical Specifications
25