CLI Guide
• For a 50-Gigabit Ethernet interface, enter the keyword
fiftyGigE then the slot/port/subport information.
• For a 100-Gigabit Ethernet interface, enter the keyword
hundredGigE then the slot/port information.
• For a Tunnel interface, enter the keyword tunnel then
the tunnel ID. The range is from 1 to 16383.
• For a VLAN interface, enter the keyword vlan then a
number from 1 to 4094.
• For a port channel interface, enter the keywords port-
channel then a number.
Defaults Not configured.
Command Modes CONFIGURATION
Command History
This guide is platform-specific. For command information about other platforms,
see the relevant Dell Networking OS Command Line Reference Guide.
Version Description
9.8(1.0) Introduced on the Z9100–ON.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000-ON.
9.4(0.0) Added the support for interfaces.
9.2(1.0) Introduced on the Z9500.
9.0.2.0 Introduced on the S6000.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
8.5.1.0 Added support for 4-port 40G line cards on the E-Series.
8.1.1.0 Introduced on the E-Series.
7.6.1.0 Introduced on the S-Series.
7.5.1.0 Introduced on the C-Series.
6.4.1.0 Introduced
Usage Information
You cannot delete a physical interface.
By default, physical interfaces are disabled (shutdown) and are not assigned to an
IP address or switchport. To place an interface in Layer 2 mode, ensure that the
interface’s configuration does not contain an IP address and enter the switchport
command.
686
Interfaces