CLI Guide
Version Description
9.0.2.0 Introduced on the S6000.
8.3.19.0 Introduced on the S4820.
8.3.7.0 Introduced on the S4810.
8.2.1.0 Introduced on the E-Series. C-Series and S-Series accept
both bytes of the 2-byte S-Tag TPID.
8.2.1.0 Introduced on the E-Series.
7.6.1.0 Introduced on the C-Series and S-Series.
E-Series original
Command
Usage Information
For specific interoperability limitations regarding the S-Tag TPID, see the Dell
Networking OS Configuration Guide.
The four characters you may enter are shown in the following table.
Number Resulting TPID
1 0x0001
10 0x0010
81 0x0081
8100 0x8100
Related
Commands
• portmode hybrid — sets a port (physical ports only) to accept both tagged and
untagged frames. A port configured this way is identified as a hybrid port in
report displays.
• vlan-stack trunk — specifies a Layer 2 port or port channel as a trunk port to the
Stackable VLAN network.
vlan-stack trunk
Specify a Layer 2 port or port channel as a trunk port to the stackable VLAN network.
Syntax
vlan-stack trunk
To remove a trunk port designation from the selected interface, use the no vlan-
stack trunk command.
Defaults Not configured.
Command Modes INTERFACE
VLAN Stacking
1673