CLI Guide

Version Description
8.3.11.4 The brief parameter no longer displays the current Reload
mode. To display Reload mode, use the show reload-
type
command. Modified the show system stack-unit
command output to support Piece Part ID (PPID).
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
7.8.1.0 The Boot Flash field displays the code level for boot code
2.8.1.1 and newer, while older boot codes display as
"Present".
7.7.1.0 Added Master Priority field.
7.6.1.0 Introduced on the S-Series.
Example
Dell#show system stack-unit 1
-- Unit 1 --
Unit Type : Management Unit
Status : online
Next Boot : online
Required Type : Z9100-ON - 34-port TE/TF/FO/FI/HU
G (Z9100-ON)
Current Type : Z9100-ON - 34-port TE/TF/FO/FI/HU
G (Z9100-ON)
Master priority : NA
Hardware Rev : 0.0
Num Ports : 130
Up Time : 37 min, 24 sec
Dell Networking OS Version : 9-8(1-270)
Jumbo Capable : yes
POE Capable : no
FIPS Mode : disabled
Boot Flash : 3.23.2.0d
Boot Selector : 3.23.0.4
Memory Size : 3177185280 bytes
Temperature : 51C
Voltage : ok
Serial Number : NA
Part Number : 11YWFG Rev X02
Vendor Id : NA
Date Code : NA
Country Code : NA
Piece Part ID : IN11YWFG282983AQ0026
PPID Revision : X02
Service Tag : 1FNRG02
Expr Svc Code : N/A
Auto Reboot : enabled
Burned In MAC : 4c:76:25:e5:49:40
No Of MACs : 3
-- Power Supplies --
Unit Bay Status Type FanStatus FanSpeed(rpm)
-----------------------------------------------------------
1 1 up AC up 9152
1 2 down UNKNOWN down 0
152