Users Guide

Version Description
7.7.1.0 Added Master Priority eld.
7.6.1.0 Introduced on the S-Series.
Example (show
system brief)
Example
Dell#show system stack-unit 1
-- Unit 1 --
Unit Type : Management Unit
Status : online
Next Boot : online
Required Type : Z9100-ON - 34-port TE/TF/FO/FI/HU G (Z9100-ON)
Current Type : Z9100-ON - 34-port TE/TF/FO/FI/HU G (Z9100-ON)
Master priority : NA
Hardware Rev : 0.0
Num Ports : 130
Up Time : 37 min, 24 sec
Dell Networking OS Version : 9-8(1-270)
Jumbo Capable : yes
POE Capable : no
FIPS Mode : disabled
Boot Flash : 3.23.2.0d
Boot Selector : 3.23.0.4
Memory Size : 3177185280 bytes
Temperature : 51C
Voltage : ok
Serial Number : NA
Part Number : 11YWFG Rev X02
Vendor Id : NA
Date Code : NA
Country Code : NA
Piece Part ID : IN11YWFG282983AQ0026
PPID Revision : X02
Service Tag : 1FNRG02
Expr Svc Code : N/A
Auto Reboot : enabled
Burned In MAC : 4c:76:25:e5:49:40
No Of MACs : 3
-- Power Supplies --
Unit Bay Status Type FanStatus FanSpeed(rpm)
---------------------------------------------------------
1 1 up AC up 9152
1 2 do UNKNOWN down 0
-- Fan Status --
Unit Bay TrayStatus Fan1 Speed Fan2 Speed
----------------------------------------------------
1 1 up up 6652 up 6812
1 2 up up 6568 up 6887
1 3 up up 6582 up 6979
1 4 up up 6695 up 6917
1 5 up up 6695 up 6812
Speed in RPM
Dell#
Related Commands
show version – displays the Dell Networking OS version.
show tech-support
Display a collection of data from other show commands, necessary for Dell Networking technical support to perform troubleshooting.
Syntax
show tech-support [stack-unit unit-id | page]
Parameters
stack-unit (OPTIONAL) Enter the keywords stack-unit to view CPU memory usage for the
stack member designated by unit-id.
Control and Monitoring 133