Users Guide

1 3 up up 6610 up 6979
1 4 up up 6680 up 6917
1 5 up up 6680 up 6812
Speed in RPM
Dell#show environment pem
-- Power Supplies --
Unit Bay Status Type FanStatus FanSpeed(rpm)
-----------------------------------------------------------
1 1 up AC up 9152
1 2 down UNKNOWN down 0
Dell#show environment thermal-sensor
-- Thermal Sensor Readings (deg C) --
Unit Sensor0 Sensor1 Sensor2 Sensor3 Sensor4 Sensor5
----------------------------------------------------------
1 48 40 50 19 19 32
Dell#
show inventory
Display the switch type, components (including media), and Dell Networking Operating System (OS), including hardware identication
numbers and congured protocols.
Syntax
show inventory [media slot]
Parameters
media slot (OPTIONAL) Enter the keyword media then the stack ID of the stack member for which
you want to display pluggable media inventory.
NOTE: This parameter is available but not supported in Dell Networking
Operating System version 8.3.11.4. Because stacking is not supported, if you
use this parameter, the output displays “Media not present or accessible”
(refer to the
Usage Information
section).
Defaults none
Command Modes CONFIGURATION
Command History
This guide is platform-specic. For command information about other platforms, see the relevant Dell Networking
OS Command Line Reference Guide.
Version Description
9.8(1.0) Introduced on the Z9100–ON.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000-ON.
9.2(1.0) Introduced on the Z9500.
9.0.2.0 Introduced on the S6000.
9.0.0.0 Introduced on the Z9000.
8.3.19.0 Introduced on the S4820T.
8.3.12.0 Introduced on the S4810.
8.3.11.4 Output expanded to include Piece Part ID (PPID) and eSR4 optics.
120 Control and Monitoring