Users Guide

EXEC Privilege mode
show tdr tengigabitethernet slot/port/subport
Splitting 40G Ports without Reload
You can split 40G interfaces into 10G ports without reboot. You can also combine the split ports to create a
40G port without reload.
On a device, fan-out profile constructs automatically with default 24 ports
(2,4,6,8,9,10,11,12,13,14,15,16,17,18,19,20,21,22,23,24,25,27,29,31) . These ports can be changed to 40G
to 10G mode or vice-versa without reload.
When a non-supported profile release is upgraded to a supported profile release, the fan-out configured
ports get automatically included in the profile. In fan-out mode, if a system is upgraded with 25 or 26
ports, only 24 ports get upgraded to fan-out mode. The rest of the ports put to default 40G mode.
In stacking, configure profile first before provisioning for new units. Otherwise it is mandatory to reload
for profile to take effect.
If there is a mismatch in fan-out profile between master and the new member in stacking, the master
re-configures the member with its quad-mode profile, quad-mode, and stack-group configuration and
then reset the member. To avoid stack split during profile mismatch, the master does stack group
configurations of the new member.
To configure the quad-port-profile, use the following command:
CONFIGURATION mode
stack-unit [stack-unit number] quad-port-profile [default | list of ports]
The defaults ports are:
2,4,6,8,9,10,11,12,13,14,15,16,17,18,19,20,21,22,23,24,25,27,29,31
Example:
stack-unit stack-unit-number quad-port-profile [default | list of ports]
To display the Fan-out capability profile, use the following show command:
show system stack-unit quad-port-profile
Example of the
show Command
The following example shows the system stack-unit quad-port-profile
command.
Dell(conf)#stack-unit 1 port 24 portmode quad
Warning: Enabling quad mode on stack-unit 1 port 24. Please
verify whether the configs related to interface Fo 1/24 are
cleaned up before proceeding further.
[confirm yes/no]:yes
Dell(conf)#00:02:24: %STKUNIT1-M:CP %IFMGR-5-DYNAMIC_FANOUT: Port
24 in slot 1 has been fanned-out >>>>>
Dell(conf)#00:02:27: %S6000-ON:1 %IFAGT-5-INSERT_OPTICS_QSFP:
Optics QSFP inserted in slot 1 port 24/2
00:02:27: %S6000-ON:1 %IFAGT-5-INSERT_OPTICS_QSFP: Optics QSFP
inserted in slot 1 port 24/3
Interfaces 434