00:08:50: %STKUNIT1-M:CP %CHMGR-5-STACKUNITDETECTED: Stack unit 2 present
00:09:00: %STKUNIT1-M:CP %CHMGR-5-CHECKIN: Checkin from Stack unit 2 (type S25P,
28 ports)
00:09:00: %S25P:2 %CHMGR-0-PS_UP: Power supply 0 in unit 2 is up
00:09:00: %STKUNIT1-M:CP %CHMGR-5-STACKUNITUP: Stack unit 2 is up
[output from the console of the unit in which diagnostics are performed]
Dell(stack-member-2)#
Diagnostic test results are stored on file: flash:/TestReport-SU-2.txt
Diags completed... Rebooting the system now!!!
The following example shows the show file flash:\\ command (standalone member).
****************************************************************
Dell# show file flash://TestReport-SU-0.txt
diagS6000CpldCacheDisable[163]: ERROR: platform cpld cache disabled ioctl failed,
rv: 9
*******************************S6000 DIAGNOSTICS*******************************
Board : S6000 Dell Inc.
CPU Version : Intel Centerton Processor
Stack Unit Board Temp : 32 Degree C
Stack Unit Number : 0
Board Service Tag : STG1234
System Cpld Rev : 0xa
Master Cpld Rev : 0xc
Slave Cpld Rev : 0xa
Image Build Version : 9-4(0-91)
**************************** S6000 LEVEL 0 DIAGNOSTICS**************************
Test 1 - Board Revision Test ........................................ PASS
Test 2 - Cpu Type Detect Test ....................................... PASS
Test 3.000 - Psu0 Presence Test ..................................... PASS
diagS6000PsuPresenceTest[1022]: ERROR: Psu:1 is not present...
Test 3.001 - Psu1 Presence Test ..................................... NOT PRESENT
Test 3 - Psu Presence Test .......................................... NOT PRESENT
Test 4.000 - Psu0 Source Type Test .................................. PASS
diagS6000IsPsuGood[954]: ERROR: Psu:1, Power supply is not present.
Test 4.001 - Psu1 Source Type Test .................................. NOT PRESENT
Test 4 - Psu Source Type Test ....................................... NOT PRESENT
Test 5.000 - Psu0 Status Monitor Test ............................... PASS
diagS6000PsuStatusMonitorTest[1099]: ERROR: Psu:1, It is not present...
Test 5.001 - Psu1 Status Monitor Test ............................... NOT PRESENT
Test 5 - Psu Status Monitor Test .................................... NOT PRESENT
Test 6.000 - Psu0 Fan Speed Monitor Test ............................ PASS
diagS6000IsPsuGood[954]: ERROR: Psu:1, Power supply is not present.
Test 6.001 - Psu1 Fan Speed Monitor Test ............................ NOT PRESENT
Test 6 - Psu Fan Speed Monitor Test ................................. NOT PRESENT
Test 7.000 - Psu0 Fan Status Monitor Test ........................... PASS
diagS6000IsPsuGood[954]: ERROR: Psu:1, Power supply is not present.
Test 7.001 - Psu1 Fan Status Monitor Test ........................... NOT PRESENT
Test 7 - Psu Fan Status Monitor Test ................................ NOT PRESENT
Test 8.000 - Psu0 Fan AirFlow Type Test ............................. PASS
diagS6000IsPsuGood[954]: ERROR: Psu:1, Power supply is not present.
Test 8.001 - Psu1 Fan AirFlow Type Test .............................NOT PRESENT
Test 8 - Psu Fan AirFlow Type Test ..................................NOT PRESENT
Test 9 - Power Rail Status Test ..................................... PASS
Test 10.000 - FanTray0 Presence Test ................................ PASS
Test 10.001 - FanTray1 Presence Test ................................ PASS
diagS6000FanTrayPresenceTest[285]: ERROR: FanTray:2 is not present.
Debugging and Diagnostics 1150