Setup Guide
Technical Specifications
This topic lists the S6010–ON specifications.
NOTE: Operate the system at an ambient temperature not higher than 113°F
(45°C).
CAUTION: Lithium Battery Caution: To avoid the possibility of an explosion,
always replace the battery correctly.
NOTE: Replace the battery only with the same or an equivalent type. Dispose of
the batteries according to the manufacturer's instructions.
Table 2. S6010–ON Chassis Physical Design
Parameter Specifications
Height 1.71 inches (43.5 mm).
Width 17.09 inches (434 mm).
Depth Chassis: 18.11 inches (460 mm).
Chassis weight with factory-installed
components
21.1 lbs (9.55 kg).
Rack clearance required
I/O side: 5 inches (12.7 cm).
PSU side: 5 inches (12.7 cm).
Table 3. Environmental Parameters
Parameter Specifications
Operating temperature 32° to 113°F (0° to 45°C).
Operating humidity 5 to 90 percent (RH), noncondensing.
Storage temperature –40° to 158°F (–40° to 70°C).
Storage and non-operating humidity 5 to 95 percent (RH), noncondensing.
Maximum thermal output 1313 BTH/hr.
4
Technical Specifications 30