Setup Guide

1 RS-232 console port
2 RJ-45 management port
NOTE: You must have a password configured on a virtual terminal line before
you can Telnet into the S6010–ON system. Therefore, use a console
connection when connecting to the system for the first time. Before starting this
procedure, be sure that you have a terminal emulation program already installed
on your PC.
1 Install an RJ-45 copper cable into the console port. Use a rollover cable to
connect the S6010–ON console port to a terminal server.
2 Connect the other end of the cable to the DTE terminal server.
3 Set the default terminal settings as follows.
115200-baud rate (set the MicroUSB console port to the same rate)
No parity
Eight data bits
One stop bit
No flow control
Accessing the RJ-45 Console Port with a
DB-9 Adapter
You can connect to the console using an RJ-45 to RJ-45 rollover cable and an
RJ-45 to DB-9 female DTE adapter to a terminal server (for example, a PC).
The pin assignments between the console and a DTE terminal server are as follows:
Table 1. Pin Assignments Between the Console and a DTE Terminal Server
S6010-ON
Console Port
RJ-45 to
RJ-45
Rollover Cable
RJ-45 to
RJ-45
Rollover Cable
RJ-45 to DB-9
Adapter
Terminal
Server Device
Signal RJ-45 Pinout RJ-45 Pinout DB-9 Pin Signal
NC 1 8 8 CTS
NC 2 7 6 DSR
TxD 3 6 2 RxD
GND 4 5 5 GND
Configure the Software 25