Setup Guide

temperature and/or particulate matter in the air might affect performance (for
example, new equipment installation).
1 Remove the fan module from the shipping box.
2 Use the grab handle to slide the module into the switch fan slot.
Figure 13. Install the Fan Module
CAUTION: DO NOT mix airflow directions. All fans must use the same airflow
direction (I/O to PSU side or PSU to I/O side).
CAUTION: Check the fans at six-month intervals and replace them as
necessary. To accurately determine replacement intervals, regularly monitor
the speeds of the cooling fans.
Installing the SFP+ and QSFP+ Optics
S6010–ON ports include 32 ports that function either as 40GbE, or, using breakout
cables, as a configuration of 96 ports of 10GbE small form-factor pluggable plus
(SFP+). The 32 ports also include eight (ports 13–20) that are 40GbE quad small
form-factor pluggable plus (QSFP+).
For a list of supported optics, see the S6010-ON Specification Sheet at
https://www.dell.com/support/ or contact your Dell Networking representative.
CAUTION
: ESD damage can occur if the components are mishandled. Always
wear an ESD-preventive wrist or heel ground strap when handling the S6010-
ON and its components.
Install the Hardware 20