Setup Guide

WARNING: Do not combine AC PSUs of different wattage. Both PSUs must use
the same wattage.
WARNING: ESD damage can occur if components are mishandled. Always
wear an ESD-preventive wrist or heel ground strap when handling the system
and its components.
WARNING: To prevent electrical shock, ensure that the system is grounded
properly. If you ground your equipment incorrectly, excessive emissions may
result. To ensure that the power cables meet your local electrical
requirements, use a qualified electrician.
CAUTION: DO NOT mix airflow directions. Both power supplies must use the
same airflow direction. The airflow direction of the power supply integrated
fans must also match the airflow direction of the fan modules.
NOTE: Ensure that the PSU is correctly installed. When you correctly install the
PSU, the power connector is on the right side of the PSU.
NOTE: Dell Networking recommends supplying power from the switch PSU to
the external power source only after the chassis is mounted in a rack or cabinet.
CAUTION: The S6010-ON contains two power cords. Disconnect both power
cords before servicing.
Connecting a DC Power Supply to the Power Source
To connect a DC PSU to the site’s DC power source, follow these steps.
Each DC power supply (PSU) comes with a connector cable. One cable is provided
for each DC PSU.
Figure 12. DC Power Supply and Connector Cable
1 DC PSU power socket.
2 Cable connector thumb screw.
3 Cable connector wires (black, green, blue).
4 Wiring block and screws.
Install the Hardware 18