Setup Guide

a Ensure the rack mating surface is clean.
b Bring any bare metal to a bright finish.
c Apply the anti-oxidant compound to the mating surfaces prior to mating.
Installing AC or DC Power Supplies
The S6010-ON is designed to support two hot-swappable power supplies with
integrated fans that provide cooling for the chassis. The system supports AC power
supplies with two air-flow directions (I/O to Utility and Utility to I/O).
1 Remove the PSU from the electrostatic bag.
2 Remove the PSU slot cover from the switch.
3 Use the grab handle to slide the PSU into the switch PSU slot. The PSU slot is
keyed such that the PSU can only be fully inserted in one orientation.
Figure 11. Install the AC or DC Power Supply Unit
4 Repeat steps 1 through 3 for the second PSU.
WARNING
: The PSU side includes two slots, PSU1 and PSU2. Although the
switch can run on one PSU, Dell Networking highly recommends using two
PSUs for full redundancy and additional cooling. To avoid overheating when
the switch is running with only a single PSU, Dell Networking recommends
using PSU1 (on the left when facing the PSU side) and covering the second
PSU slot opening (PSU2) with a blank plate.
Install the Hardware 17