Install Guide

LED behavior
The following system LED behavior is seen during open networking installation environment (ONIE) operations:
Figure 5. S6010–ON I/O side LEDs
1
Master LED 2 Status LED
3 Locator LED 4 RS–232/RJ-45 Serial Console Port LED
5 QSFP+ LEDs 6 Stack ID LED
7 Management Port Link LED 8 Fan LED
9 Power LED
Table 1. S6010–ON I/O-side LED behavior
LED Description
Master
O—switch is in stacking slave mode
Solid green—system is in stacking master or standalone mode
Status
Solid green—normal operation
Blinking green—booting
Solid amber—critical system error
Blinking amber—noncritical system error—fan failure or power
supply failure
Locator
O—locator function is disabled
Blinking blue—locator function is enabled
QSFP+ port when used as one 40G port. Only the rst LED is used
in 40G mode.
O—No Link
Solid green—link at 40G speed
Blinking green—port activity at 40G speed
Solid amber—link at speed lower than 40G
Blinking amber—port activity at lower than 40G speed
S6010–ON System 9