Install Guide
Specications
This chapter lists the S6010–ON specications.
CAUTION: Operate the product at an ambient temperature not higher than 113°F (45°C).
CAUTION: Lithium Battery Caution: There is a danger of explosion if the battery is incorrectly replaced. Replace only with same
or equivalent type of battery. Dispose of the batteries according to the manufacturer's instructions.
NOTE: For RoHS information, see Restricted Material Compliance.
Topics:
• Chassis Physical Design
• IEEE standards
• Agency Compliance
Chassis Physical Design
Table 3. Chassis physical design
Parameter Specications
Height 1.71 inches (43.5 mm)
Width 17.09 inches (434 mm)
Depth 18.11 inches (460 mm)
Weight 21.7 lbs (9.86 kg)
Table 4. Environmental parameters
Parameter Specications
Operating Temperature 32° to 113°F (0° to 45°C)
Operating Humidity 5% to 90% (RH), noncondensing
Storage Temperature –40° to 158°F (–40° to 70°C)
Storage Humidity 5% to 95% (RH), noncondensing
Maximum Thermal Output 1153.265BTU/hr
Table 5. AC power requirements
Parameter Specications
Power Supply 100–240Vac 50/60Hz
Maximum Current Draw Per System
4.11A @411W/100Vac
9
Specications 39