Install Guide
Figure 18. S6010–ON AC power supply installation
1 1–PSU 2 2–PSU slot
When you install the PSU correctly, it snaps into place and is ushed with the back of the switch.
4 Plug in the appropriate three-prong AC power cord from the switch PSU to the external power source.
5 Repeat steps 1 through 4 using the second PSU slot if you have a redundant PSU.
NOTE
: The S6010–ON powers up when you connect the cables between the power supply and the power source.
AC power supply replacement
CAUTION
: Disconnect the power cord before removing the power supplies. Also, disconnect all power cords before servicing.
NOTE: The PSU slides into the slot smoothly. Do not force a PSU into a slot as this action may damage the PSU or the S6010–
ON chassis.
NOTE: If a PSU fails, replace the entire unit. There are no eld serviceable components in the PSU. To request a hardware
replacement, see Dell Support.
NOTE: If you use a single PSU, install a blank plate in the other PSU slot. Dell recommends using power supply 1 (PSU1) as the
blank plate slot.
1 Disconnect the power cable from the PSU.
2 Use the grab handle to slide the PSU out of the power supply bay.
3 Use the grab handle on the replacement PSU to slide it into the power supply bay.
4 Attach the power cord to the replacement PSU.
NOTE
: The system powers up when you connect the cables between the power supply and the power source.
DC power supply connection
Each sold-separately DC PSU kit comes with a connector cable.
Power supplies
31