Concept Guide
• Prevent the stack master from rebooting after a failover.
CONFIGURATION mode
redundancy disable-auto-reboot stack-unit
This command does not aect a forced failover, manual reset, or a stack-link disconnect.
• Display redundancy information.
EXEC Privilege mode
show redundancy
Resetting a Unit on a Stack
You may reset any stack unit except for the master management unit, as shown in the following message.
% Error: Reset of master unit is not allowed.
To rest a unit on a stack, use the following commands.
• Reload a stack-unit.
EXEC Privilege mode
reset stack-unit unit-number
• Reload a member unit, from the unit itself.
EXEC Privilege mode
reset-self
• Reset a stack-unit when the unit is in a problem state.
EXEC Privilege mode
reset stack-unit unit-number {hard}
Verify a Stack Conguration
The light of the LED status indicator on the front panel of the stack identies the unit’s role in the stack.
• O indicates the unit is a stack member.
• The master LED is in OFF state for the standby unit.
• Solid green indicates the unit is the stack master (management unit).
Displaying the Status of Stacking Ports
To display the status of the stacking ports, including the topology, use the following command.
• Display the stacking ports.
EXEC Privilege mode
show system stack-ports
Examples of Viewing the Status for Stacked Switches
The following example shows the parameters for the management unit in the stack.
930
Stacking