Administrator Guide

Line Description
Tx Power High
Alarm Flag
This can be either true or false, depending on the Current Tx bias power value displayed
above.
Rx Power High
Alarm Flag
This can be either true or false, depending on the Current Rx power value displayed
above.
Temperature Low
Alarm Flag
This can be either true or false, depending on the Current Temperature value displayed
above.
Voltage Low Alarm
Flag
This can be either true or false, depending on the Current voltage value displayed above.
Tx Bias Low Alarm
Flag
This can be either true or false, depending on the Tx bias current value displayed above.
Tx Power Low
Alarm Flag
This can be either true or false, depending on the Current Tx power value displayed
above.
Rx Power Low
Alarm Flag
This can be either true or false, depending on the Current Rx power value displayed
above.
Temperature High
Warning Flag
This can be either true or false, depending on the Current Temperature value displayed
above.
Voltage High
Warning Flag
This can be either true or false, depending on the Current Voltage value displayed above.
Tx Bias High
Warning Flag
This can be either true or false, depending on the Tx bias current value displayed above.
Tx Power High
Warning Flag
This can be either true or false, depending on the Current Tx power value displayed
above.
Rx Power High
Warning Flag
This can be either true or false, depending on the Current Tx power value displayed
above.
Temperature Low
Warning Flag
This can be either true or false, depending on the Current Temperature value displayed
above.
Voltage Low
Warning Flag
This can be either true or false, depending on the Current Voltage value displayed above.
Tx Bias Low
Warning Flag
This can be either true or false, depending on the present Tx bias current value displayed
above.
Tx Power Low
Warning Flag
This can be either true or false, depending on the Current Tx power value displayed
above.
Rx Power Low
Warning Flag
This can be either true or false, depending on the Current Rx power value displayed
above.
Example
DellEMC#show interfaces tengigabitethernet 1/1/2 transceiver
Interface Name : TenGigabitEthernet 1/1/2
SFP is present
SFP+ 1/2 Serial Base ID fields
SFP+ 1/2 Id = 0x03
SFP+ 1/2 Ext Id = 0x04
SFP+ 1/2 Connector = 0x22
SFP+ 1/2 Transceiver Code = 0x00 0x00 0x00 0x00 0x00 0x00
0x00 0x00
SFP+ 1/2 Encoding = 0x00
SFP+ 1/2 BR Nominal = 0x64
SFP+ 1/2 Length(SFM) Km = 0x00
SFP+ 1/2 Length(SFM) 100m = 0x00
SFP+ 1/2 Length(OM3) 10m = 0x00
SFP+ 1/2 Length(OM2) 10m = 0x00
SFP+ 1/2 Length(OM1) 10m = 0x00
SFP+ 1/2 Length(Copper-1m/AOC-1m/OM4-10m) = 0x1e
SFP+ 1/2 Vendor Name = Methode Elec.
SFP+ 1/2 Vendor PN = SP7051-D
672 Interfaces