Users Guide
reload-type fastboot
Restart the system with optimized booting-time functionality enabled. When you restart the device in fast
boot mode, traffic disruption is reduced significantly and the system operations to service the data traffic are
restored in a seamless way.
C9000 Series
Syntax
reload-type fastboot
Parameters
fastboot Enable the system to restart the next time with the optimized
booting-time capability
Defaults By default, the device reloads in Jumpstart or BMP mode.
Command Modes GLOBAL CONFIGURATION
Command History
This guide is platform-specific. For command information about other platforms, refer
to the relevant Dell Networking OS Command Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.10(0.1) Introduced on the S6010-ON and S4048T-ON.
9.8(1.0) Introduced on the Z9100–ON.
9.3(0.0) Added support for the fastboot parameter for S6000 platform.
Usage Information
You can configure an optimization technique to reduce the booting time of an S6000
Switch. This mechanism is also called fast boot. With the reduced time that is taken to
reboot the switch, upon a manually-initiated reload or an expected restart of the
device, the disruption in traffic that is serviced by the switch is minimized. Traffic
outage is lowered considerably (reduced to approximately 25 seconds in certain
network deployments) when you enable this optimization method for booting of the
device. By reducing the duration of traffic loss, subscriber sessions are processed and
preserved in an effective and seamless way.
Flex Hash and Optimized Boot-Up 671