Users Guide
Version Description
9.10(0.0) Introduced on the S6000, S6000–ON, S61000–ON, Z9100–
ON.
Usage Information The queue-drop backoff-on-norxpfc polling-count command is used to
remove the queue-drop state if additional PFCs are not received for the specified
number of polling intervals.
Example Use the storm-control pfc command in the configuration mode to enter the
‘storm-control-pfc' configuration mode. The commands provisioned in this mode are
applicable for all the interfaces that have PFC storm enabled.
Dell(conf)#storm-control pfc
Dell(conf-storm-control-pfc)#queue-drop backoff-on-norxpfc
polling-count 20
show storm-control broadcast
Display the storm control broadcast configuration.
Syntax
show storm-control broadcast [interface]
Parameters
interface (OPTIONAL) Enter one of the following interfaces to display the
interface-specific storm control configuration:
• For a 10-Gigabit Ethernet interface, enter the keyword
TenGigabitEthernet then the slot/port/subport
information.
• For a 40-Gigabit Ethernet interface, enter the keyword
fortyGigE then the slot/port information.
Defaults none
Command Modes
• EXEC
• EXEC Privilege
Command History
This guide is platform-specific. For command information about other platforms, see
the relevant Dell Networking OS Command Line Reference Guide.
Version Description
9.10(0.1) Introduced on the S6010-ON and S4048T-ON.
9.10(0.0) Introduced on the S6100–ON.
9.8(1.0) Introduced on the Z9100–ON.
9.8(0.0P5) Introduced on the S4048-ON.
Storm Control 1763