Users Guide
Version Description
9.0.0.0 Introduced on the Z9000.
8.3.19.0 Introduced on the S4820T.
8.3.11.4 The brief parameter no longer displays the current Reload
mode. To display Reload mode, use the show reload-type
command. Modified the show system stack-unit command
output to support Piece Part ID (PPID).
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
7.8.1.0 The Boot Flash field displays the code level for boot code 2.8.1.1
and newer, while older boot codes display as "Present".
7.7.1.0 Added Master Priority field.
7.6.1.0 Introduced on the S-Series.
Example (show
system stack unit
– disabled ports)
Dell# show system stack-unit 1 disabled-ports
Disabled ports in stack-unit 1
Disabled
52
56
60
Example (show
system brief)
Dell# sh system brief
Stack MAC : 00:00:00:00:00:00
Reload-Type : normal-reload [Next boot : normal-reload]
-- Stack Info --
Unit UnitType Status ReqTyp CurTyp Version Ports
---------------------------------------------------------------------------
1 Management Software Failure S6000-ON S6000-ON 9-7(0-288) 128
2 Member not present
3 Member not present
4 Member not present
5 Member not present
6 Member not present
-- Power Supplies --
Unit Bay Status Type FanStatus FanSpeed(rpm)
-----------------------------------------------------------
1 1 up AC up 18528
1 2 absent absent 0
-- Fan Status --
Unit Bay TrayStatus Fan0 Speed Fan1 Speed
----------------------------------------------------
1 1 up up 19660 up 19275
1 2 absent
1 3 up up 19275 up 18904
Speed in RPM
Example (S6000–
ON)
Dell> show system stack-unit 1
-- Unit 1 --
Unit Type : Management Unit
Status : Card Problem - Software Failure
Next Boot : online
Required Type : S6000-ON - 32-port TE/FG (SI-ON)
Control and Monitoring 162