Setup Guide

Example 2: service timestamps log datetime utc
DellEMC(conf)#service timestamps log datetime utc
Example 3: service timestamps log uptime
DellEMC(conf)#service timestamps log uptime
Example 4: no service timestamps log
DellEMC(conf)#no service timestamps log
DellEMC# show command-history
- Repeated 1 time.
[1d0h26m]: CMD-(CLI):[configure]by default from console
- Repeated 1 time.
[May 17 15:53:10]: CMD-(CLI):[no service timestamps log]by default from console
[May 17 15:53:16]: CMD-(CLI):[write memory]by default from console
- Repeated 3 times.
[May 17 15:53:22]: CMD-(CLI):[show logging]by default from console
- Repeated 1 time.
[May 17 15:53:36]: CMD-(CLI):[write memory]by default from console
- Repeated 5 times.
[May 17 15:53:44]: CMD-(CLI):[show logging]by default from console
[May 17 15:53:53]: CMD-(CLI):[show command-history]by default from console
[May 17 15:54:54]: CMD-(CLI):[end]by default from console
[May 17 15:55:00]: CMD-(CLI):[show logging]by default from console
[May 17 15:55:12]: CMD-(CLI):[show clock]by default from console
[May 17 15:55:22]: CMD-(CLI):[show running-config]by default from console
[May 17 15:55:27]: CMD-(CLI):[show command-history]by default from console
Upgrading Dell EMC Networking OS
To upgrade Dell EMC Networking Operating System (OS), refer to the Release Notes for the version you want to load on the system.
You can download the release notes of your platform at https://www.force10networks.com. Use your login ID to log in to the website.
Using HTTP for File Transfers
Stating with Release 9.3(0.1), you can use HTTP to copy les or conguration details to a remote server. To transfer les to an external
server, use the
copy source-le-url http://host[:port]/le-path command.
Enter the following source-le-url keywords and information:
To copy a le from the internal FLASH, enter ash:// followed by the lename.
To copy the running conguration, enter the keyword running-cong.
To copy the startup conguration, enter the keyword startup-cong.
To copy a le on the USB device, enter usbash:// followed by the lename.
In the Dell EMC Networking OS release 9.8(0.0), HTTP services support the VRF-aware functionality. If you want the HTTP server to use a
VRF table that is attached to an interface, congure that HTTP server to use a specic routing table. You can use the ip http vrf
command to inform the HTTP server to use a specic routing table. After you congure this setting, the VRF table is used to look up the
destination address.
NOTE
: To enable HTTP to be VRF-aware, as a prerequisite you must rst dene the VRF.
You can specify either the management VRF or a nondefault VRF to congure the VRF awareness setting.
Getting Started
55