White Papers
Recover from a Card Problem State on a Stack
If a unit added to a stack has a dierent Dell EMC Networking OS version, the unit does not come online and Dell EMC Networking OS
cites a card problem error.
To recover, disconnect the new unit from the stack, change the Dell EMC Networking OS version to match the stack, and then reconnect
it to the stack.
Example of Card Problem Error on a Stack - Dierent Dell EMC Networking OS Versions
DellEMC#show system brief
Stack MAC : 90:b1:1c:f4:a7:c7
Reload-Type : normal-reload [Next boot : normal-reload]
-- Stack Info --
Unit UnitType Status ReqTyp CurTyp Version Ports
------------------------------------------------------------------------------------
0 Member not present S6000 unknown 128
1 Member not present
2 Standby online S6000 S6000 1-0(0-3387) 128
3 Member not present S6000
4 Member not present
5 Management online S6000 S6000 1-0(0-3387) 128
-- Power Supplies --
Unit Bay Status Type FanStatus FanSpeed(rpm)
---------------------------------------------------------------------------
2 0 up AC up 6720
2 1 up AC up 6688
5 0 up AC up 6688
5 1 down UNKNOWN down 0
-- Fan Status --
Unit Bay TrayStatus Fan0 Speed Fan1 Speed
------------------------------------------------------------------------------------
2 0 up up 7072 up 6971
2 1 up up 7021 up 7021
2 2 up up 7021 up 6971
5 0 up up 7021 up 7123
5 1 up up 6971 up 7021
5 2 up up 7021 up 6971
Speed in RPM
Stacking