White Papers
MIB Object OID Description
dellNetIfTransSerialNumber 1.3.6.1.4.1.6027.3.11.1.3.1.1.7 Species the Serial Number of the Optic
inserted
dellNetIfTransTransmitPowerLane1 1.3.6.1.4.1.6027.3.11.1.3.1.1.8 Species Lane 1 Tx power value in dBm
dellNetIfTransTransmitPowerLane2 1.3.6.1.4.1.6027.3.11.1.3.1.1.9 Species Lane 2 Tx power value in dBm
dellNetIfTransTransmitPowerLane3 1.3.6.1.4.1.6027.3.11.1.3.1.1.10 Species Lane 3 Tx power value in dBm
dellNetIfTransTransmitPowerLane4 1.3.6.1.4.1.6027.3.11.1.3.1.1.11 Species Lane 4 Tx power value in dBm
dellNetIfTransReceivePowerLane1 1.3.6.1.4.1.6027.3.11.1.3.1.1.12 Species Lane 1 Rx power value in dBm
dellNetIfTransReceivePowerLane2 1.3.6.1.4.1.6027.3.11.1.3.1.1.13 Species Lane 2 Rx power value in dBm
dellNetIfTransReceivePowerLane3 1.3.6.1.4.1.6027.3.11.1.3.1.1.14 Species Lane 3 Rx power value in dBm
dellNetIfTransReceivePowerLane4 1.3.6.1.4.1.6027.3.11.1.3.1.1.15 Species Lane 4 Rx power value in dBm
dellNetIfTransTemperature 1.3.6.1.4.1.6027.3.11.1.3.1.1.16 Species Temperature value of the Optics
inserted
SNMP Example Output (Single Interface)
DellEMC$ snmpwalk -v 2c -c public -m all -M 10.16.150.140 .1.3.6.1.4.1.6027.3.11.1.3 | grep
2112517
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransDeviceName.2112517 = STRING: "stack-unit-1
port-31"
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransPort.2112517 = STRING: "Fo 1/49/1"
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransOpticsPresent.2112517 = INTEGER: true(1)
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransOpticsType.2112517 = STRING: "40GBASE-LR4"
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransVendorName.2112517 = STRING: "FINISAR CORP."
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransPartNumber.2112517 = STRING: "FTL4C1QE1C-FC"
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransSerialNumber.2112517 = STRING: "UNF0FKU"
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransTransmitPowerLane1.2112517 = ""
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransTransmitPowerLane2.2112517 = ""
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransTransmitPowerLane3.2112517 = ""
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransTransmitPowerLane4.2112517 = ""
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransReceivePowerLane1.2112517 = STRING: "-1.433315"
dBm
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransReceivePowerLane2.2112517 = STRING: "0.051805"
dBm
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransReceivePowerLane3.2112517 = STRING: "-0.270108"
dBm
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransReceivePowerLane4.2112517 = STRING: "-0.134970"
dBm
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransTemperature.2112517 = STRING: "37.816406"
degrees Centigrade
MIB Support to Display the Available Memory Size on
Flash
Dell EMC Networking provides more MIB objects to display the available memory size on ash memory. The following table lists the MIB
object that contains the available memory size on ash memory.
Table 100. MIB Objects for Displaying the Available Memory Size on Flash via SNMP
MIB Object OID Description
chStackUnitFlashUsageUtil 1.3.6.1.4.1.6027.3.10.1.2.9.1.6 Contains ash memory usage in percentage.
The chStackUnitUtilTable MIB table contains the chStackUnitFlashUsageUtil MIB object which contains the ash memory usage percent.
The chStackUnitUtilTable is located in f10SSerChassisMib MIB.
868
Simple Network Management Protocol (SNMP)