Reference Guide
Simple Network Management Protocol and Syslog | 899
Parameters
Defaults
6 or informational
Command Modes
CONFIGURATION
Command
History
Related
Commands
show logging
s z
Display the logging settings and system messages logged to the internal buffer of the switch.
Syntax
show logging [number | history [reverse][number] | reverse [number] | summary]
Parameters
Command Modes
EXEC
EXEC Privilege
Command
History
Figure 42-11. show logging Command Example (Partial)
FTOS#show logging
Syslog logging: enabled
Console logging: level debugging
Monitor logging: level debugging
Buffer logging: level debugging, 5604 Messages Logged, Size (524288 bytes)
Trap logging: level informational
Oct 8 09:25:37: %RPM1:RP1 %BGP-5-ADJCHANGE: Connection with neighbor
223.80.255.254 closed. Hold time expired
Oct 8 09:25:38: %RPM1:RP1 %BGP-5-ADJCHANGE: Neighbor 192.200.13.2 Up
Oct 8 09:25:38: %RPM1:RP1 %BGP-5-ADJCHANGE: Neighbor 192.1.1.13 Up
level
Indicate a value from 0 to 7 or enter one of the following parameters: emergencies, alerts,
critical, errors, warnings, notifications, informational, or debugging.
The default is 6.
Version 9.0.2.0 Introduced on the S6000.
Version 8.3.11.1 Introduced on Z9000
Version 7.6.1.0 Support added for S-Series
logging Enable the logging to another device.
logging on Enables logging.
S6000
number
(OPTIONAL) Enter the number of message to be displayed on the output.
Range: 1 to 65535
history (OPTIONAL) Enter the keyword history to view only information in the Syslog history
table.
reverse (OPTIONAL) Enter the keyword reverse to view the Syslog messages in FIFO (first in,
first out) order.
summary (OPTIONAL) Enter the keyword summary to view a table showing the number of
messages per type and per slot.
Slots *7* and *8* represent RPMs.
Version 9.0.2.0 Introduced on the S6000.
Version 8.3.11.1 Introduced on Z9000
Version 7.6.1.0 Support added for S-Series