Reference Guide
68 | Control and Monitoring
www.dell.com | support.dell.com
Parameters
Command Modes
EXEC
EXEC Privilege
Command
History
Example
FTOS#show environment
-- Fan Status --
Unit Bay TrayStatus Fan0 Speed Fan1 Speed Fan2 Speed Temp
------------------------------------------------------------------------------
--
0 0 up up 9600 up 9600 up 9600 29
0 1 up up 9600 up 9600 up 9600 43
Speed in RPM
-- Power Supplies --
Unit Bay Status Type
---------------------------------------------------------------------------
0 0 down DC
0 1 up DC
-- Unit Environment Status --
Unit Status Temp Voltage
---------------------------------------------------------------------------
* 0 online 50C ok
* Management Unit
-- Thermal Sensor Readings (deg C) --
Unit Sensor0 Sensor1 Sensor2 Sensor3 Sensor4 Sensor5
---------------------------------------------------------------------------
0 37 40 44 52 50 52
FTOS#
all Enter the keyword all to view all components.
fan Enter the keyword fan to view information on the fans. The output of this
command is chassis dependent.
stack-unit unit-id Enter the keyword stack-unit followed by the unit-id to display
information on a specific stack member.
Unit ID range:
S4810: 0-11
pem Enter the keyword pem to view only information on power entry
modules.
Version 9.0.2.0 Introduced on S6000.
Version 8.3.11.1 Introduced on the Z9000.
Version 7.6.1.0 Introduced on S-Series.
Version 7.8.1.0 The output of the show environment fan command for S-Series is changed