Reference Guide

Control and Monitoring | 63
FTOS#
The following table provides descriptions for the status response symbols displayed in output.
reload
s z
Reboot FTOS.
Syntax
reload
Command Modes
EXEC Privilege
Command
History
Usage
Information
If there is a change in the configuration, FTOS will prompt you to save the new configuration.
Or you can save your running configuration with the copy running-config command.
Refer to the
Jumpstart: Automated Bare Metal Configuration (BMAC) chapter for information
related to the BMAC reload options.
Related
Commands
send
s z
Send messages to one or all terminal line users.
Syntax
send [*] | [line ] | [console] | [vty]
Table 1 ping command Status Response Symbols and Descriptions
Symbol Description
! Each exclamation point indicates receipt of a reply
. Each period indicates the network server timed out while waiting
for a reply
U A destination unreachable error PDU was received
Q Source quench (destination too busy)
M Could not fragment
? Unknown packet type
& Packet lifetime exceeded
S6000
Version 9.0.2.0 Introduced on S6000.
Version 8.3.11.1 Introduced on the Z9000.
Version 7.6.1.0 Introduced on S-Series.
send Reset a stack-unit, RPM, a standby SFM (EtherScale only), or a failed SFM
(TeraScale and ExaScale).
S6000