Reference Guide
Interfaces | 453
Bias Low Alarm threshold Factory-defined setting. Value can differ between SFP and SFP+.
TX Power Low Alarm
threshold
Factory-defined setting. Value can differ between SFP and SFP+.
RX Power Low Alarm
threshold
Factory-defined setting. Value can differ between SFP and SFP+.
Temp High Warning threshold Factory-defined setting. Value can differ between SFP and SFP+.
Voltage High Warning
threshold
Factory-defined setting. Value can differ between SFP and SFP+.
Bias High Warning threshold Factory-defined setting. Value can differ between SFP and SFP+.
TX Power High Warning
threshold
Factory-defined setting. Value can differ between SFP and SFP+.
RX Power High Warning
threshold
Factory-defined setting. Value can differ between SFP and SFP+.
Temp Low Warning threshold Factory-defined setting. Value can differ between SFP and SFP+.
Voltage Low Warning
threshold
Factory-defined setting. Value can differ between SFP and SFP+.
Bias Low Warning threshold Factory-defined setting. Value can differ between SFP and SFP+.
TX Power Low Warning
threshold
Factory-defined setting. Value can differ between SFP and SFP+.
Power Low Warning threshold Factory-defined setting. Value can differ between SFP and SFP+.
Temperature Current temperature of the sfps.If this temperature crosses Temp High alarm/
warning thresholds, then the temperature high alarm/warning flag is set to
true.
Voltage Current voltage of the sfps.If this voltage crosses voltage high alarm/warning
thresholds, then the voltage high alarm/warning flag is set to true.
Tx Bias Current Present Tx bias current of the SFP. If this crosses bias high alarm/warning
thresholds, then the tx bias high alarm/warning flag is set to true. If it falls
below the low alarm/warning thresholds, then the tx bias low alarm/warning
flag is set to true.
Tx Power Present Tx power of the SFP. If this crosses Tx power alarm/warning
thresholds, then the Tx power high alarm/warning flag is set to true. If it falls
below the low alarm/warning thresholds, then the Tx power low alarm/
warning flag is set to true.
Rx Power Present Rx power of the SFP. This value is either average Rx power or
OMA.This depends upon on the Rx Power measurement type displayed
above. If this crosses Rx power alarm/warning thresholds, then the Rx power
high alarm/warning flag is set to true. If it falls below the low alarm/warning
thresholds, then the Rx power low alarm/warning flag is set to true.
Data Ready state Bar This field indicates that the transceiver has achieved power up and data is
ready. This is set to true if data is ready to be sent, false if data is being
transmitted.
Rx LOS state This is the digital state of the Rx_LOS output pin.This is set to true if the
operating status is down.
Tx Fault state This is the digital state of the Tx Fault output pin.
Rate Select state This is the digital state of the SFP rate_select input pin.
Table 20-9. Diagnostic Data in show interfaces transceiver (continued)
Line Description