Reference Guide

Interfaces | 439
Command Modes
EXEC
EXEC Privilege
Command History
Usage
Use this show interfaces command for details on a specific interface. Use the show interfaces
linecard
command for details on all interfaces on the designated stack-unit.
On the S4810, the show interface output displays incorrect rate information details over time for link
monitoring when the rate-interval is configured for 5 seconds. Dell Networks recommends using
higher rate-intervals such as 15 to 299 seconds to minimize the errors seen.
Note: In the CLI output, the power value will be rounded to a 3-digit value. For receive/transmit power
that is less than 0.000, an snmp query will return the corresponding dbm value even though the CLI
displays as 0.000.
Note: After the counters are cleared, the line-rate continues to increase until it reaches the maximum
line rate. When the maximum line rate is reached, there will be no change in the stack-unit
Example
Figure 20-25. show interfaces Command Example for 10G Port
FTOS# show interfaces tengigabitethernet 2/0
TenGigabitEthernet 2/0 is up, line protocol is up
Hardware is FTOSEth, address is 00:01:e8:05:f7:3a
Interface index is 100990998
Internet address is 213.121.22.45/28
MTU 1554 bytes, IP MTU 1500 bytes
LineSpeed 10000 Mbit
ARP type: ARPA, ARP Timeout 04:00:00
Last clearing of "show interfaces" counters 02:31:45
Queueing strategy: fifo
Input Statistics:
0 packets, 0 bytes
Input 0 IP Packets, 0 Vlans 0 MPLS
0 64-byte pkts, 0 over 64-byte pkts, 0 over 127-byte pkts
0 over 255-byte pkts, 0 over 511-byte pkts, 0 over 1023-byte pkts
0 symbol errors, 0 runts, 0 giants, 0 throttles
0 CRC, 0 IP Checksum, 0 overrun, 0 discarded
Output Statistics:
1 packets, 64 bytes, 0 underruns
0 Multicasts, 2 Broadcasts, 0 Unicasts
0 IP Packets, 0 Vlans, 0 MPLS
0 throttles, 0 discarded
Rate info (interval 299 seconds):
Input 00.00 Mbits/sec, 0 packets/sec, 0.00% of line-rate
Output 00.00 Mbits/sec, 0 packets/sec, 0.00% of line-rate
Time since last interface status change: 00:00:27
Version 9.0.2.0 Introduced on then S6000.
Version 8.3.11.1 Introduced on the Z9000.
Version 8.2.1.0 Introduced on the S4810
Version 6.4.1.0 Changed organization of display output