Reference Guide

Interfaces | 437
rate-interval
s z
Configure the traffic sampling interval on the selected interface.
Syntax
rate-interval seconds
Parameters
Defaults 299 seconds
Command Modes
INTERFACE
Command History
Usage Information
The configured rate interval is displayed, along with the collected traffic data, in the output of show
interfaces
commands.
Related
Commands
show config
s z
Display the interface configuration.
Syntax
show config
Command Modes
INTERFACE
Command History
Example
Figure 20-23. show config Command Example for the INTERFACE Mode
FTOS(conf-if-fo-0/4)#show config
!interface fortyGigE 0/4
no ip address
mtu 12000
switchport
no shutdown
FTOS(conf-if-fo-0/4)#
S6000
seconds Enter the number of seconds for which to collect traffic data.
Range: 30 to 299 seconds
Note: Since polling occurs every 15 seconds, the number of seconds designated
here will round to the multiple of 15 seconds lower than the entered value. For
example, if 44 seconds is designated it will round to 30; 45 to 59 seconds will
round to 45, and so forth.
Version 9.0.2.0 Introduced on then S6000.
Version 8.3.11.1 Introduced on the Z9000.
Version 8.2.1.0 Introduced on the S4810
show interfaces Display information on physical and virtual interfaces.
S6000
Version 9.0.2.0 Introduced on then S6000.
Version 8.3.11.1 Introduced on the Z9000.
Version 8.2.1.0 Introduced on the S4810