Reference Guide

Interfaces | 431
Parameters
Command Modes
EXEC
EXEC Privilege
Command History
Usage Information
The delta column displays changes since the last screen refresh.
Example
Figure 20-16. monitor Command Example of a Single Interface
systest-3 Monitor time: 00:00:06 Refresh Intvl.: 2s Time: 03:26:26
Interface: Gi 0/3, Enabled, Link is Up, Linespeed is 1000 Mbit
Traffic statistics: Current Rate Delta
Input bytes: 9069828 43 Bps 86
Output bytes: 606915800 43 Bps 86
Input packets: 54001 0 pps 1
Output packets: 9401589 0 pps 1
64B packets: 67 0 pps 0
Over 64B packets: 49166 0 pps 1
Over 127B packets: 350 0 pps 0
Over 255B packets: 1351 0 pps 0
Over 511B packets: 286 0 pps 0
Over 1023B packets: 2781 0 pps 0
Error statistics:
Input underruns: 0 0 pps 0
Input giants: 0 0 pps 0
Input throttles: 0 0 pps 0
Input CRC: 0 0 pps 0
Input IP checksum: 0 0 pps 0
Input overrun: 0 0 pps 0
Output underruns: 0 0 pps 0
Output throttles: 0 0 pps 0
m - Change mode c - Clear screen
l - Page up a - Page down
T - Increase refresh interval t - Decrease refresh interval
q - Quit
Figure 20-17. monitor Command Example of All Interfaces on a stack-unit
systest-3 Monitor time: 00:01:31 Refresh Intvl.: 2s Time: 03:54:14
Interface Link In Packets [delta] Out Packets
[delta]
Gi 0/0 Down 0 0 0
0
interface
(OPTIONAL) Enter the following keywords and slot/port or number information:
For an 100/1000 Ethernet interface, enter the keyword
GigabitEthernet
followed by the slot/port information.
For a 1-Gigabit Ethernet interface, enter the keyword
GigabitEthernet followed
by the slot/port information.
For the management port, enter the keyword
managementethernet followed
by the slot (0-1) and the port (0).
For a 10-Gigabit Ethernet interface, enter the keyword
TenGigabitEthernet
followed by the slot/port information.
For a 40-Gigabit Ethernet interface, enter the keyword
fortyGigE followed by the
slot/port information.
Version 9.0.2.0 Introduced on then S6000.
Version 8.3.11.1 Introduced on the Z9000.
Version 8.2.1.0 Introduced on the S4810