Concept Guide

MIB Support for Power Monitoring
Dell EMC Networking provides MIB objects to display the information for Power Monitoring. The OIDs specic to Power Monitoring are
appended to the DellITaMIbs. There are three separate DellITaMIbs available to display the current input power, average input power and
average input-power start time. These statistics can also be obtained by using the CLI command:
show environment
. The following table
lists the related MIB objects, OID and description for the same:
Table 105. MIB Objects to Display the Information for Power Monitoring
MIB Object OID Description
envMonSupplyCurrentPower 1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.5 Displays per PSU input power (current
conguration).
envMonSupplyAveragePower 1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.6 Displays average input power.
envMonSupplyAvgStartTime 1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.7 Displays average input-power start time.
SNMP Walk Example Output
snmpwalk -v 2c -c public 10.16.131.156 1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.5
SNMPv2-SMI::enterprises.674.10895.3000.1.2.110.7.2.1.5.11 = INTEGER: 48
SNMPv2-SMI::enterprises.674.10895.3000.1.2.110.7.2.1.5.12 = INTEGER: 40
snmpwalk -v 2c -c public 10.16.131.156 1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.6
SNMPv2-SMI::enterprises.674.10895.3000.1.2.110.7.2.1.6.11 = INTEGER: 31
SNMPv2-SMI::enterprises.674.10895.3000.1.2.110.7.2.1.6.12 = INTEGER: 26
snmpwalk -v 2c -c public 10.16.131.156 1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.7
SNMPv2-SMI::enterprises.674.10895.3000.1.2.110.7.2.1.7.11 = STRING: "04/25/2017-18:32"
SNMPv2-SMI::enterprises.674.10895.3000.1.2.110.7.2.1.7.12 = STRING: "04/25/2017-18:32"
MIB Support for 25G, 40G, 50G, 100G Optical
Transceiver or DAC cable IDPROM user info
Dell EMC Networking provides MIB objects to display the information for 25G, 40G, 50G, 100G Optical Transceiver or DAC cable IDPROM.
The following table lists the related MIB objects, OID and description for the same:
Table 106. MIB Objects to Display support for 25G, 40G, 50G, 100G Optical Transceiver or DAC cable IDPROM user info
MIB Object OID Description
dellNetIfTransceiverData 1.3.6.1.4.1.6027.3.11.1.3 Species the Transceiver Data Main
dellNetIfTransceiverDataTable 1.3.6.1.4.1.6027.3.11.1.3.1 Species the Transceiver Data Table
dellNetIfTransceiverDataEntry 1.3.6.1.4.1.6027.3.11.1.3.1.1 Species the Transceiver Data Entry Point
dellNetIfTransDeviceName 1.3.6.1.4.1.6027.3.11.1.3.1.1.1 Species the Transceiver Device name
dellNetIfTransPort 1.3.6.1.4.1.6027.3.11.1.3.1.1.2 Species the Transceiver Port Name
dellNetIfTransOpticsPresent 1.3.6.1.4.1.6027.3.11.1.3.1.1.3 Species whether Optics is present in the
Port or not
dellNetIfTransOpticsType 1.3.6.1.4.1.6027.3.11.1.3.1.1.4 Species the Optic Type inserted
dellNetIfTransVendorName 1.3.6.1.4.1.6027.3.11.1.3.1.1.5 Species the Vendor Name of the Optic
inserted
dellNetIfTransPartNumber 1.3.6.1.4.1.6027.3.11.1.3.1.1.6 Species the Part Number of the Optic
inserted
Simple Network Management Protocol (SNMP) 899