Users Guide

Example of a Syslog
Figure 120. Creating a new stack
In the above example, stack unit 1 is the master management unit, stack unit 2 is the standby unit. The cables are connected to each unit.
Configure the stack groups on the units in the following order:
Configure the first stack group on unit 1: stack-unit 1 stack-group 13
Configure the stack groups on unit 2: stack-unit 2 stack-group 14 and stack-unit 2 stack-group 15
Configure the stack groups on unit 3: stack-unit 3 stack-group 12 and stack-unit 3 stack-group 13
Configure the stack groups on unit 4: stack-unit 4 stack-group 13 and stack-unit 4 stack-group 31
Configure the final stack-group on unit 1 to complete the stack: stack-unit 1 stack-group 31
When the stack-group configuration is complete, the system prints a syslog for reload.
Dell#configure
Dell(conf)#stack-unit 4 stack-group 13
Dell(conf)#02:39:12: %STKUNIT4-M:CP %IFMGR-6-STACK_PORTS_ADDED: Ports Fo 4/52 have been
configured as
stacking ports. Please save and reload for config to take effect
Dell(conf)#stack-unit 4 stack-group 14
Dell(conf)#02:39:15: %STKUNIT4-M:CP %IFMGR-6-STACK_PORTS_ADDED: Ports Fo 4/56 have been
configured as
stacking ports. Please save and reload for config to take effect
Dell(conf)#
Dell#02:39:18: %STKUNIT4-M:CP %SYS-5-CONFIG_I: Configured from console
Dell(conf)#stack-unit 5 stack-group 28
Dell(conf)#1d16h8m: %STKUNIT5-M:CP %IFMGR-6-STACK_PORTS_ADDED: Ports Fo 5/112 have been
configured as stacking ports. Please save and reset stack-unit 5 for config to take effect
Dell(conf)#stack-unit 0 stack-group 29
Dell(conf)#1d16h8m: %STKUNIT5-M:CP %IFMGR-6-STACK_PORTS_ADDED: Ports Fo 0/116 have been
configured as stacking ports. Please save and reset stack-unit 0 for config to take effect
Reload each unit in the stack. After the reload is complete, the four units come up as a stack with unit 1 as the management unit, unit 2 as
the standby unit, and the remaining units as stack-members. All units in the stack can be accessed from the management unit.
To view the stack unit information after the reload, use the show system brief command.
Dell#show system brief
Stack MAC : 90:b1:1c:f4:a7:c7
Reload-Type : normal-reload [Next boot : normal-reload]
868
Stacking