Dell Command Line Reference Guide for the S6000 System 9.8(0.
Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. Copyright © 2015 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws.
Contents 1 About this Guide............................................................................................................ 38 Objectives........................................................................................................................................................................ 38 Audience..........................................................................................................................................................................
Control and Monitoring.................................................................................................. 81 banner exec...................................................................................................................................................................... 81 banner login......................................................................................................................................................................82 banner motd.............
show processes memory................................................................................................................................................ 129 show software ifm.......................................................................................................................................................... 132 show system...........................................................................................................................................................
deny..........................................................................................................................................................................175 ip access-list standard...............................................................................................................................................176 permit..............................................................................................................................................................
match ip next-hop.................................................................................................................................................... 224 match ip route-source.............................................................................................................................................. 225 match metric............................................................................................................................................................
seq (for Standard MAC ACLs)........................................................................................................................................267 permit tcp (for Extended IP ACLs).................................................................................................................................268 seq arp (for Extended MAC ACLs).................................................................................................................................
bgp add-path........................................................................................................................................................... 305 bgp always-compare-med........................................................................................................................................305 bgp asnotation.........................................................................................................................................................
neighbor distribute-list............................................................................................................................................. 344 neighbor ebgp-multihop........................................................................................................................................... 345 neighbor fall-over.....................................................................................................................................................
show running-config bgp......................................................................................................................................... 400 timers bgp................................................................................................................................................................400 MBGP Commands..........................................................................................................................................................
iscsi priority-bits....................................................................................................................................................... 436 show interface dcbx detail........................................................................................................................................437 dcb-map....................................................................................................................................................................
dns-server................................................................................................................................................................ 481 domain-name............................................................................................................................................................ 481 excluded-address.....................................................................................................................................................
15 Equal Cost Multi-Path (ECMP)................................................................................. 509 ecmp-group................................................................................................................................................................... 509 hash-algorithm................................................................................................................................................................510 ip ecmp-group..........................
19 GARP VLAN Registration (GVRP)............................................................................. 544 clear gvrp statistics........................................................................................................................................................545 debug gvrp.................................................................................................................................................................... 545 disable...................................
dampening............................................................................................................................................................... 582 description............................................................................................................................................................... 583 duplex (10/100 Interfaces).......................................................................................................................................
show port-channel-flow........................................................................................................................................... 642 Enhanced Validation of Interface Ranges....................................................................................................................... 644 ip http source-interface..................................................................................................................................................
show ip cam stack-unit.................................................................................................................................................. 688 show ip fib stack-unit.....................................................................................................................................................690 show ip flow........................................................................................................................................................
default-information originate.......................................................................................................................................... 738 description..................................................................................................................................................................... 739 distance.......................................................................................................................................................
show config....................................................................................................................................................................776 show isis database.......................................................................................................................................................... 777 show isis graceful-restart detail...........................................................................................................................
fefd interval..............................................................................................................................................................820 fefd mode................................................................................................................................................................. 821 fefd reset........................................................................................................................................................
ip msdp mesh-group...................................................................................................................................................... 853 ip msdp originator-id...................................................................................................................................................... 854 ip msdp peer.......................................................................................................................................................
ipv6 neighbor............................................................................................................................................................ 891 managed-config-flag................................................................................................................................................892 match ra...................................................................................................................................................................
default-metric...........................................................................................................................................................927 description............................................................................................................................................................... 928 distance............................................................................................................................................................
show ip ospf database summary...............................................................................................................................974 show ip ospf interface.............................................................................................................................................. 976 show ip ospf neighbor..............................................................................................................................................
redirect......................................................................................................................................................................... 1022 seq................................................................................................................................................................................1024 show cam pbr.....................................................................................................................................
41 Per-VLAN Spanning Tree Plus (PVST+).................................................................... 1066 description....................................................................................................................................................................1066 disable...........................................................................................................................................................................1067 extend system-id.....................
service-policy input................................................................................................................................................. 1103 service-policy output...............................................................................................................................................1104 service-queue.........................................................................................................................................................
offset-list....................................................................................................................................................................... 1142 output-delay.................................................................................................................................................................. 1143 passive-interface...................................................................................................................................
aaa radius group...................................................................................................................................................... 1184 show accounting..................................................................................................................................................... 1185 Authorization and Privilege Commands.........................................................................................................................
dot1x authentication (Configuration).......................................................................................................................1222 dot1x authentication (Interface)..............................................................................................................................1223 dot1x auth-fail-vlan................................................................................................................................................. 1223 dot1x auth-server.
ip dhcp source-address-validation...........................................................................................................................1257 ip dhcp snooping vlan............................................................................................................................................. 1257 show ip dhcp snooping...........................................................................................................................................
snmp-server user................................................................................................................................................... 1295 snmp-server user (for AES128-CFB Encryption).................................................................................................... 1298 snmp-server view...................................................................................................................................................1299 snmp-server vrf..........
show storm-control multicast....................................................................................................................................... 1335 show storm-control unknown-unicast.......................................................................................................................... 1336 storm-control broadcast (Configuration).......................................................................................................................
tunnel destination..........................................................................................................................................................1374 tunnel dscp................................................................................................................................................................... 1375 tunnel flow-label..........................................................................................................................................
59 Virtual Link Trunking (VLT)...................................................................................... 1406 back-up destination...................................................................................................................................................... 1406 clear vlt statistics..........................................................................................................................................................1407 delay-restore.......................
IPv4 VRRP Commands................................................................................................................................................. 1437 advertise-interval.................................................................................................................................................... 1437 authentication-type................................................................................................................................................
1 About this Guide This book provides information about the Dell Networking OS command line interface (CLI). This book also includes information about the protocols and features found in Dell Networking OS.
Information Icons This book uses the following information symbols: NOTE: The Note icon signals important operational information. CAUTION: The Caution icon signals information about situations that could result in equipment damage or loss of data. WARNING: The Warning icon signals information about hardware handling that could result in injury.
2 CLI Basics This chapter describes the command line interface (CLI) structure and command modes. The Dell Networking operating software commands are in a text-based interface that allows you to use the launch commands, change command modes, and configure interfaces and protocols. Accessing the Command Line When the system boots successfully, you are positioned on the command line in EXEC mode and not prompted to log in. You can access the commands through a serial console port or a Telnet session.
In this case, the user is “admin” on vty2. Obtaining Help As soon as you are in a command mode there are several ways to access help. To obtain a list of keywords at any command mode: Type a ? at the prompt or after a keyword. There must always be a space before the ?. To obtain a list of keywords with a brief functional description: Type help at the prompt. To obtain a list of available options: Type a keyword and then type a space and a ?.
• To navigate left or right in the Dell Networking OS command line, use the left and right Arrow keys. The shortcut key combinations at the Dell Networking OS command line are as follows: Key Combination Action CNTL-A Moves the cursor to the beginning of the command line. CNTL-B Moves the cursor back one character. CNTL-D Deletes the character at the cursor. CNTL-E Moves the cursor to the end of the line. CNTL-F Moves the cursor forward one character. CNTL-I Completes a keyword.
Using the Keyword no Command To disable, delete or return to default values, use the no form of the commands. For most commands, if you type the keyword no in front of the command, you disable that command or delete it from the running configuration. In this guide, the no form of the command is described in the Syntax portion of the command description.
Enabling Software Features on Devices Using a Command Option This capability to activate software applications or components on a device using a command is supported on the S4810, S4820T, and S6000, platforms. Starting with Release 9.4(0.0), you can enable or disable specific software functionalities or applications that need to run on a device by using a command attribute in the CLI interface.
show feature Verify the status of software applications, such as VRF, that are activated and running on a device. S6000 Syntax show feature Command Modes EXEC EXEC Privilege Command History Version 9.4(0.0) Introduced on the S4810, S4820T, and S6000. Usage Information You can activate VRF application on a device by using the feature vrf command in CONFIGURATION mode. The no feature vrf command is not supported on any of the platforms.
1. Verify that you are logged in to EXEC Privilege mode. 2. Enter the configure command. The prompt changes to include (conf). From this mode, you can enter INTERFACE mode by using the interface command. CONTROL-PLANE Mode To manage control-plane traffic, use CONTROL-PLANE mode. For more information, refer to Control Plane Policing (CoPP). To enter CONTROL-PLANE mode: 1. Verify that you are logged in to CONFIGURATION mode. 2. Enter the control-plane-cpuqos command.
EXEC Mode When you initially log in to the switch, by default, you are logged in to EXEC mode. This mode allows you to view settings and enter EXEC Privilege mode, which is used to configure the device. When you are in EXEC mode, the > prompt is displayed following the host name prompt, which is “Dell” by default. You can change the host name prompt using the hostname command. NOTE: Each mode prompt is preceded by the host name. EXEC Privilege Mode The enable command accesses EXEC Privilege mode.
Prompt Interface Type Dell(conf-ifgi-0/0)# Gigabit Ethernet interface then the slot/port information Dell(conf-ifte-0/0)# Ten-Gigabit Ethernet interface then slot/port information Dell(conf-iffo-0/0)# Forty-Gigabit Ethernet interface then slot/port information Dell(conf-iflo-0)# Loopback interface number Dell(conf-ifnu-0)# Null Interface then zero Dell(conf-ifpo-0)# Port-channel interface number Dell(conf-ifvl-0)# VLAN Interface then VLAN number (range 1–4094) Dell(conf-ifma-0/0)# Managemen
1. To enable LLDP globally, verify that you are logged in to CONFIGURATION mode. To enable LLDP on an interface, verify that you are logged in to INTERFACE mode. 2. Enter the protocol lldp command. The prompt changes to include (conf-lldp) or (conf-if-interface-lldp). LLDP MANAGEMENT INTERFACE Mode To enable and configure Link Layer Discovery Protocol (LLDP) on management interfaces, use LLDP MANAGEMENT INTERFACE mode. To enter LLDP MANAGEMENT INTERFACE mode: 1.
OPENFLOW INSTANCE Mode To enable and configure OpenFlow instances, use OPENFLOW INSTANCE mode. To enter OPENFLOW INSTANCE mode: 1. Verify that you are logged in to CONFIGURATION mode. 2. Enter the openflow of-instance command then the OpenFlow ID number of the instance you want to create or configure. The prompt changes to include (conf-of-instance of-id). You can return to the CONFIGURATION mode by entering the exit command.
RAPID SPANNING TREE (RSTP) Mode To enable and configure RSTP, use RSTP mode. For more information, refer to Rapid Spanning Tree Protocol (RSTP). To enter RSTP mode: 1. Verify that you are logged in to CONFIGURATION mode. 2. Enter the protocol spanning-tree rstp command. The prompt changes to include (conf-rstp). You can return to CONFIGURATION mode by using the exit command. ROUTE-MAP Mode To configure a route map, use ROUTE-MAP mode. To enter ROUTE-MAP mode: 1.
ROUTER OSPFV3 Mode To configure OSPF for IPv6, use ROUTER OSPFV3 mode. To enter ROUTER OSPFV3 mode: 1. Verify that you are logged in to CONFIGURATION mode. 2. Enter the ipv6 router ospf {process-id} command. The prompt changes to include (conf-ipv6-router_ospf). You can return to CONFIGURATION mode by using the exit command. ROUTER RIP Mode To enable and configure Router Information Protocol (RIP), use ROUTER RIP mode. For more information, refer to Routing Information Protocol (RIP).
VRRP Mode To enable and configure Virtual Router Redundancy Protocol (VRRP), use VRRP mode. For more information, refer to Virtual Router Redundancy Protocol (VRRP). To enter VRRP mode: 1. To enable VRRP globally, verify that you are logged in to CONFIGURATION mode. 2. Enter the vrrp-group command then enter the VRRP group ID. The prompt changes to include (conf-if-interface-type-slot/ port-vrid-vrrp-group-id).
3 File Management This chapter contains command line interface (CLI) commands needed to manage the configuration files as well as other file management commands. boot system Tell the system where to access the Dell Networking OS image used to boot the system. Syntax boot system {gateway ip address| stack-unit [{stack-unit-number | all] [default | primary {system {A: | B: | bmp-boot} | tftp: | | secondary]} To return to the default boot sequence, use the no boot system command.
Usage Information Version Description 9.7(0.0) Introduced the support for bmp-boot on the S-Series and Z-Series switches. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. To display these changes in the show bootvar command output, save the running configuration to the startup configuration (using the copy command) and reload system. The keyword bmp-boot is used only when the device boots up from BMP.
Version Description E-Series Original command. HTTP Copy via CLI Copy one file to another location. Dell Networking OS supports IPv4 and IPv6 addressing for FTP, TFTP, and SCP (in the hostip field). This feature is supported on S6000 platform. Syntax copy http://10.16.206.77/sample_file flash://sample_filecopy flash:// sample_file http://10.16.206.77/sample_file You can copy from the server to the switch and vice-versa. Parameters copy http: flash: Address or name of remote host []: 10.16.206.
compressed-config file-url Enter the keyword compressed-config to copy one file, after optimizing and reducing the size of the configuration file, to another location. Dell Networking OS supports IPv4 and IPv6 addressing for FTP, TFTP, and SCP (in the hostip field).
To copy a file from an external USB drive enter usbflash://filepath Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON.
You can compress the running configuration by grouping all the VLANs and the physical interfaces with the same property. Support to store the operating configuration to the startup config in the compressed mode and to perform an image downgrade without any configuration loss are provided. Two existing exec mode CLIs are enhanced to display and store the running configuration in the compressed mode. Example Dell#copy running-config scp:/ Address or name of remote host []: 10.10.10.
• For a file or directory on the NFS mounted file system, enter nfsmount:// followed by the mount point and the file path. NOTE: While deleting a file directory on a remote NFS file system, it is mandatory to specify the mount-point that indicates the working directory on the NFS file system. You cannot delete the root directory of the remote NFS file system. • no-confirm For a file or directory on an external USB drive, enter usbflash:// followed by the filename or directory name.
Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.7(0.0) Added support for NFS mount. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 7.8.1.
Usage Information Include the colon (:) when entering this command. This command checks the specified flash memory for errors. If errors are found, the command recommends that you format the flash. CAUTION: If you elect to format the flash, all files – including the startup configuration file – are lost. If you do decide to format the specified flash, consider saving the running configuration as the startup configuration after formatting the flash (use the write memory command or copy run start command).
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S-Series. Example Dell#mount nfs nfstest nfs-mount-point usrname pwd Related Commands cd – changes the working directory. rmdir Removes a directory from the NFS mounted file system.
nfsmount:// / filepath Enter the keyword nfsmount: and specify the location of the image file in the format //
rename Rename a file in the local file system. Syntax rename url url Parameters url Enter the following keywords and a filename: • For a file on the internal Flash, enter flash:// followed by the filename. • For a file on an NFS mounted file system, enter nfsmount:// followed by the mount point and file path. • For a file on an external USB drive, enter usbflash:// followed by the filename. Command Modes EXEC Privilege Command History This guide is platform-specific.
• Command History EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000 8.3.7.0 Introduced on the S4810. 7.7.1.
Example Version Description E-Series Original command. Dell#show bootvar PRIMARY IMAGE FILE = system://B SECONDARY IMAGE FILE = tftp://10.16.127.35/Dell-SI-9-0-2-0.
Command Fields Field Description size(b) Lists the size (in bytes) of the storage location. If the location is remote, no size is listed. Free(b) Lists the available size (in bytes) of the storage location. If the location is remote, no size is listed. Feature Displays the formatted DOS version of the device. Type Displays the type of storage. If the location is remote, the word network is listed. Flags Displays the access available to the storage location.
Example Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series Original command.
arp for the current static ARP configuration as-path for the current AS-path configuration bfd for the current BFD configuration bgp for the current BGP configuration boot for the current boot configuration cam-profile for the current CAM profile in the configuration class-map for the current class-map configuration communitylist for the current community-list configuration ecmp-group for the current ECMP group configuration eis for the current EIS configuration ethernet for the current
File Management managementroute for the current Management port forwarding configuration mld for the current MLD configuration monitor for the current Monitor configuration mroute for the current Mroutes configuration msdp for the current MSDP configuration ntp for the current NTP configuration ospf for the current OSPF configuration pim for the current PIM configuration policy-mapinput for the current input policy map configuration policy-mapoutput for the current output policy map
users for the current users configuration vlt for the current VLT configuration wred-profile for the current wred-profile configuration configured (OPTIONAL) Enter the keyword configuration to display line card interfaces with non-default configurations only. status (OPTIONAL) Enter the keyword status to display the checksum for the running configuration and the start-up configuration. compressed (Optional) Enter the keyword compressed to display the compressed group configuration.
redundancy disable-auto-reboot redundancy disable-auto-reboot redundancy disable-auto-reboot redundancy disable-auto-reboot redundancy disable-auto-reboot redundancy disable-auto-reboot ! hardware watchdog stack-unit 0 hardware watchdog stack-unit 1 hardware watchdog stack-unit 2 stack-unit stack-unit stack-unit stack-unit stack-unit stack-unit 0 1 2 3 4 5 Example Dell#show running-config status running-config bytes 10257, checksum 0xFD33339F startup-config bytes 10257, checksum 0xFD33339F Usage Inform
redundancy disable-auto-reboot stack-unit ... Related Commands show running-config – displays the current (running) configuration. show version Display the current Dell Networking Operating System (OS) version information on the system. Syntax show version Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Example (S-Series) Lines Beginning With Description 1 Route Processor... Hardware configuration of the system, including the number and type of physical interfaces available Dell#show version Dell Real Time Operating System Software Dell Operating System Version: 1.0 Dell Application Software Version: E7-8-1-13 Copyright (c) 1999-2008 by Dell Force10 Networks, Inc.
upgrade system Upgrade the system image. S6000 Syntax Parameters upgrade system {flash: | ftp: | scp: | tftp: | usbflash: | stack-unit {0-5 | all} {A: | B:} 0–5 Enter the keywords 0–5 to upgrade only the mentioned stack-unit. all Enter the keyword all to upgrade all the member units of the stack. ftp Enter the keyword ftp to follow it with the location of the source file in this form: //userid:password@hostip/filepath, or press Enter to launch a prompt sequence.
userid:password@hostip/filepath) stack-unit Sync image to the stack-unit tftp: Copy from remote file system, IPv4 or IPv6, (tftp:// hostip/filepath) usbflash: Copy from usbflash file system (usbflash://filepath) Dell# upgrade boot Upgrade the bootflash image or bootselector image.
Version 8.3.11.1 Introduced on the Z9000. Added support for the SSD on the Z9000 only. Version 8.3.7.0 Introduced on the S4810. Version 7.7.1.0 Added support for TFTP and SCP. Version 7.6.1.0 Introduced on the S-Series. Usage Information You must reload Dell Networking OS after executing this command.
Example Without Entering the Hash Value for Verification using SHA256 Dell# verify sha256 flash://FTOS-SE-9.5.0.0.bin SHA256 hash for FTOS-SE-9.5.0.0.bin: e6328c06faf814e6899ceead219afbf9360e986d692988023b749e6b2093e933 Entering the Hash Value for Verification using SHA256 Dell# verify sha256 flash://FTOS-SE-9.5.0.0.bin e6328c06faf814e6899ceead219afbf9360e986d692988023b749e6b2093e933 SHA256 hash VERIFIED for FTOS-SE-9.5.0.0.
4 Control and Monitoring This chapter contains the commands to configure and monitor the system, including Telnet, file transfer protocol (FTP), and trivial file transfer protocol (TFTP). NOTE: Starting in version 9.0.2.0, the enable xfp-power-updates command was deprecated for the S6000 This command replaces the enable optic-info-update interval command to update information on temperature and power monitoring in the simple network management protocol (SNMP) management information base (MIB).
Version Description E-Series Original Command Usage Information After entering the banner login command, type one or more spaces and a delineator character. Enter the banner text then the second delineator character. When the user is connected to the router, if a message of the day banner is configured, it displays first. If no message of the day banner is configured, the login banner and prompt appear. After the user has logged in, the banner EXEC (if configured) displays.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.2.1.0 Introduced the keyword keyboard-interactive.
banner motd Set a message of the day (MOTD) banner. Syntax banner motd c line c To delete a Message of the Day banner, enter no banner motd. Parameters c Enter a delineator character to specify the limits of the text banner. The delineator is a percent character (%). line Enter a text string for your MOTD banner the message with your delineator. The delineator is a percent character (%). Defaults No banner is configured.
cam-acl Allocate content addressable memory (CAM) for IPv4 and IPv6 ACLs.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.1.0 Added the keywords ecfmacl, vman-qos, and vman-dual-qos. 8.2.1.0 Introduced on the S-Series. 7.8.1.0 Introduced on the C-Series. For the new settings to take effect, save the new CAM settings to the startup-config (write-mem or copy run start) then reload the system. The total amount of space allowed is 16 FP Blocks. System flow requires three blocks and these blocks cannot be reallocated.
Version Description 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series Original command. configure Enter CONFIGURATION mode from EXEC Privilege mode. Syntax Parameters configure [terminal] terminal (OPTIONAL) Enter the keyword terminal to specify that you are configuring from the terminal. Command Modes EXEC Privilege Command History This guide is platform-specific.
disable Return to EXEC mode. Syntax disable [level] Parameters level (OPTIONAL) Enter a number for a privilege level of the Dell Networking OS. The range is from 0 to 15. The default is 1. Defaults 1 Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Usage Information Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series.
Usage Information Version Description 9.5(0.0) Added support for roles on the Z9000, S6000, S4820T, S4810, and MXL. 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series Original command.
Usage Information Version Description 8.3.11.4 Replacement command for the Z9000. Replaces the enable xfp-powerupdates command 8.3.10.0 Replacement command for the S4810 only. Replaces the enable xfp-powerupdates command. To enable polling and to configure the polling frequency, use this command. end Return to EXEC Privilege mode from other command modes (for example, CONFIGURATION or ROUTER OSPF modes).
Related Commands Version Description E-Series Original command. exit — returns to the lower command mode. exec-timeout Set a time interval that the system waits for input on a line before disconnecting the session. Syntax exec-timeout minutes [seconds] To return to default settings, use the no exec-timeout command. Parameters minutes Enter the number of minutes of inactivity on the system before disconnecting the current session. The range is from 0 to 35791.
exit Return to the lower command mode. Syntax Command Modes Command History exit • EXEC Privilege • CONFIGURATION • LINE, INTERFACE • TRACE-LIST • PROTOCOL GVRP • SPANNING TREE • MULTIPLE SPANNING TREE • MAC ACCESS LIST • ACCESS-LIST • AS-PATH ACL • COMMUNITY-LIST • PREFIX-LIST • ROUTER OSPF • ROUTER RIP • ROUTER ISIS • ROUTER BGP This guide is platform-specific.
ftp-server enable Enable FTP server functions on the system. Syntax ftp-server [vrf vrf-name] enable Parameters vrf vrf-name Enter the keyword vrf and then the name of the VRF to enable the FTP server to listen to that VRF instance. NOTE: Use this attribute to specify the VRF that is used by the FTP server to accept client connections. If no VRF is specified, then the default VRF is used. Defaults Disabled Command Modes CONFIGURATION Command History This guide is platform-specific.
329 bytes received in 0.018 seconds (17.95 Kbytes/s) ftp> ftp-server topdir Specify the top-level directory to be accessed when an incoming FTP connection request is made. Syntax Parameters ftp-server topdir directory directory Enter the directory path. Defaults The internal flash is the default directory. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
To delete a user name and its password, use the no ftp-server username username command. Parameters username Enter a text string up to 40 characters long as the user name. password password Enter the keyword password then a string up to 40 characters long as the password. Without specifying an encryption type, the password is unencrypted.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series Original command. The password is listed in the configuration file; you can view the password by entering the show running-config ftp command. Use the ip ftp password command when you use the ftp: parameter in the copy command.
Version 8.3.19.0 Introduced on the S4820T. Version 8.3.11.1 Introduced on the Z9000. Version 8.3.7.0 Introduced on the S4810. Version 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. Version 8.2.1.0 Increased number of VLANs on ExaScale to 4094 (was 2094). Version 8.1.1.0 Introduced on the E-Series ExaScale. Version 7.6.1.0 Introduced on the S-Series. Version 7.5.1.0 Introduced on the C-Series. E-Series Original command.
ip ftp username Assign a user name for outgoing FTP connection requests. Syntax ip ftp username username To return to anonymous FTP connections, use the no ip ftp username [username] command. Parameters username Enter a text string as the user name up to 40 characters long. Defaults No user name is configured. Command Modes CONFIGURATION Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9500. 9.4(0.0) Introduced on the S-Series and Z9000. Use this command to make the FTP clients VRF-aware.
ip telnet server vrf Configures the TELNET server on either a specific VRF or a management VRF. S6000 Syntax ip telnet server vrf {management | vrf-name} To undo the TELNET server configuration, use the no ip telnet server [vrf vrf-name] command. Parameters vrf management Enter the keyword vrf followed by the keyword management to specify a management VRF that is used by the TELNET server.
• For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For Loopback interfaces, enter the keyword loopback then a number from zero (0) to 16383. • For a port channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For VLAN interface, enter the keyword vlan then a number from 1 to 4094. • For a tunnel interface, enter the keyword tunnel.
Defaults Disabled Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9500. 9.4.(0.0) Introduced on the S-Series and Z9000.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series Original command Usage Information You cannot delete a terminal connection. Related Commands access-class — restricts the incoming connections to a particular IP address in an IP access control list (ACL).
To limit the number of concurrent sessions that any user can have on console, auxiliary, and virtual terminal lines, use the login concurrent-session limit number-of-sessions command. If the login concurrent-session clear-line enable command is configured, you are provided with an option to clear any of your existing sessions after a successful login authentication. When you reach the maximum concurrent session limit, you can still log in by clearing any of your existing sessions.
login statistics Enable and configure user login statistics on console and virtual terminal lines. Syntax login statistics {enable | time-period days} no login statistics {enable | time-period days} Parameters enable Enables user login statistics. By default, the system displays the login statistics for the last 30 days. time-period days Sets the number of days for which the system stores the user login statistics. The range is from 1 to 30.
The preceding message shows that the user had previously logged in to the system using the VTY line from 10.14.1.97. It also displays the number of unsuccessful login attempts since the last login and the number of unsuccessful login attempts in the last 30 days. $ telnet 10.11.178.14 Trying 10.11.178.14... Connected to 10.11.178.14. Escape character is '^]'.
Version Description 7.5.1.0 Introduced on the C-Series. E-Series Original command ping Test connectivity between the system and another device by sending echo requests and waiting for replies.
df-bit (IPv4 only) Enter Y or N for the “don't fragment” bit in IPv4 header. • N: Do not set the “don't fragment” bit. • Y: Do set “don't fragment” bit Default is No. validate-reply (IPv4 only) Enter Y or N for reply validation. • N: Do not validate reply data. • Y: Do validate reply data. Default is No. Defaults outgoing-interface (IPv6 link-local address) Enter the outgoing interface for ping packets to a destination link-local address.
Usage Information Version 8.3.11.1 Introduced on the Z9000. Version 8.3.7.0 Introduced on the S4810. Version 8.5.1.0 Added support for 4-port 40G line cards on the ExaScale. Version 8.4.1.0 IPv6 pinging available on management interface. Version 8.3.1.0 Introduced extended ping options. Version 8.2.1.0 Introduced on the E-Series ExaScale (IPv6). Version 8.1.1.0 Introduced on the E-Series ExaScale (IPv4). Version 7.9.1.0 Introduced VRF. Version 7.6.1.0 Introduced on the S-Series.
Success rate is 100.0 percent (5/5), round-trip min/avg/max = 0/0/0 (ms) Dell# reload Reboot Dell Networking Operating System (OS). Syntax reload [conditional nvram-cfg-change] Parameters conditional nvramcfg-change Reload if the condition is true. A configuration change to the nvram requires a switch reload. To reload the switch, select nvram-cfg-change. Command Modes EXEC Privilege Command History This guide is platform-specific.
vty Enter the keyword vty to send a message to the virtual terminal. Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000.
show-timezone (OPTIONAL) Enter the keyword show-timezone to include the time zone information in the timestamp. uptime (OPTIONAL) Enter the keyword uptime to have the timestamp based on time elapsed since system reboot. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.
no Defaults Display all of the commands that may be preceded by the keyword no, which is the keyword used to remove a command from the running-configuration. none Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.
show cpu-traffic-stats View the CPU traffic statistics. Syntax Parameters show cpu-traffic-stats [port number | all | cp ] port number (OPTIONAL) Enter the port number to display traffic statistics on that port only. The range is from 1 to 1568. all (OPTIONAL) Enter the keyword all to display traffic statistics on all the interfaces receiving traffic, sorted based on the traffic. cp (OPTIONAL) Enter the keyword cp to display traffic statistics on the specified CPU.
Received 37% traffic on TenGigabitEthernet 8/1 Total packets:300 LLC:0, SNAP:0, IP:300, ARP:0, other:0 Unicast:300, Multicast:0, Broadcast:0 Processor : RP2 --------------No CPU traffic statistics. Dell# show debugging View a list of all enabled debugging processes. Syntax show debugging Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
show environment View S-Series and Z-Series system component status (for example, temperature or voltage). Syntax Parameters Command Modes Command History show environment [all | fan | stack-unit unit-id | pem ] all Enter the keyword all to view all components. fan Enter the keyword fan to view information on the fans. The output of this command is chassis dependent. stack-unit unit-id Enter the keyword stack-unit then the unit-id to display information on a specific stack member.
--------------------------------------------------------------------------* 0 online 36C ok 1 * Management Unit -- Thermal Sensor Readings (deg C) -Unit Sensor0 Sensor1 Sensor2 Sensor3 Sensor4 Sensor5 Sensor6 --------------------------------------------------------------------0 40 36 37 37 31 31 46 Dell#show environment fan -- Fan Status -Unit Bay TrayStatus Fan0 Speed Fan1 Speed -----------------------------------------------------------------------------------0 0 up up 7021 up 7021 0 1 up up 6971 up 7072
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.4 Output expanded to include Piece Part ID (PPID) and eSR4 optics. 8.3.11.1 Introduced on the Z9000. 7.6.1.0 Introduced this version of the command for S-Series. S-Series output differs from E-Series.
show login statistics Displays login statistics of users who have used the console or virtual terminal lines to log in to the system. Syntax show login statistics [[unsuccessful-attempts [user login-id] [time-period days]] | [all | user login-id]] Parameters all (Optional)Displays the login statistics of all users in the last 30 days or the custom defined time period. user login-id (Optional)Displays the login statistics of a specific user in the last 30 days or the custom defined time period.
-----------------------------------------------------------------User: admin Last login time: Mon Feb 16 04:40:00 2015 Last login location: Line vty0 ( 10.14.1.97 ) Unsuccessful login attempt(s) since the last successful login: 0 Unsuccessful login attempt(s) in last 30 day(s): 3 -----------------------------------------------------------------The following is sample output of the show login statistics all command.
show memory View current memory usage on the switch. Syntax show memory [stack-unit id] Parameters Command Modes Command History stack-unit id • EXEC • EXEC Privilege (OPTIONAL) Enter the keyword stack-unit then the stack unit ID of the SSeries stack member to display memory information on the designated stack member. The unit ID range from 0 to 5. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Parameters management-unit 1-99 [details] (OPTIONAL) Display processes running in the control processor. The 1-99 variable sets the number of tasks to display in order of the highest CPU usage in the past five (5) seconds. Add the keyword details to display all running processes (except sysdlp). Refer to Example (management-unit). stack-unit id (OPTIONAL) Enter the keyword stack-unit then the stack member ID.
CPU utilization of sysdlp for five seconds: 2%/0%; one minute: 3%; minutes: 1% PID Runtime(ms) Invoked uSecs 5Sec 1Min TTY Process 0xbb773000 5950 595 10000 1.00% 2.25% 0 tExcTask 0xbab2a000 4030 403 10000 1.00% 1.33% 0 frrpagt 0xbacf3000 10 1 10000 0.00% 0.00% 0 F10StkMgr 0xbad0c000 710 71 10000 0.00% 0.00% 0 lcMgr 0xbad24000 30 3 10000 0.00% 0.00% 0 dla 0xbad44000 50 5 10000 0.00% 0.00% 0 sysAdmTsk 0xbad58000 650 65 10000 0.00% 0.00% 0 timerMgr 0xbad6e000 50 5 10000 0.00% 0.
0.08% 0 0.00% 0 0.00% 0 0.00% 0 49 48 47 46 1010 sflCp 30 snmp 0 dpi_cmow 0 dpi_taskcmo 101 10000 0.05% 0.07% 3 10000 0.00% 0.00% 0 0 0.00% 0.00% 0 0 0.00% 0.
show hardware system-flow — displays Layer 3 ACL or QoS data for the selected stack member and stack member port-pipe. show interfaces stack-unit — displays information on all interfaces on a specific S-Series stack member. show processes memory (S-Series) — displays CPU usage information based on processes running in an SSeries. show processes ipc flow-control Display the single window protocol queue (SWPQ) statistics.
Usage Information Version Description 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series and E-Series.
Parameters Command Modes Command History management-unit Enter the keyword management-unit for CPU memory usage of the stack management unit. stack unit unit id Enter the keyword stack unit then a stack unit ID of the member unit for which to display memory usage on the forwarding processor. all Enter the keyword all for detailed memory usage on all stack members. summary Enter the keyword summary for a brief summary of memory availability and usage on all stack members.
show processes memory output Description Frees Total dynamic memory freed Max Maximum dynamic memory allocated Current Current dynamic memory in use Field The output for the show process memory command displays the memory usage statistics running on CP part (sysd) of the system. The sysd is an aggregate task that handles all the tasks running on S-Series’ CP. For the S-Series, the output of the show memory command and this command differ based on which FTOS processes are counted.
265 bcmLINK.0 117927936 0 0 0 !----------- output truncated --------------! 0 0 show software ifm Display interface management (IFM) data. Syntax show software ifm {clients [summary] | ifagt number | ifcb interface | stack-unit unit-ID | trace-flags} Parameters clients Enter the keyword clients to display IFM client information. summary (OPTIONAL) Enter the keyword summary to display brief information about IFM clients.
Example Version Description 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 7.6.1.0 Introduced for the C-Series and S-Series.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Added support for the disabled-ports parameter . 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.11.4 The brief parameter no longer displays the current Reload mode. To display Reload mode, use the show reload-type command. Modified the show system stack-unit command output to support Piece Part ID (PPID). 8.3.11.
Example (S6000) Dell#show system Stack MAC : 90:b1:1c:f4:9b:79 Reload-Type : normal-reload [Next boot : normal-reload] -- Unit 0 -Unit Type : Management Unit Status : online Next Boot : online Required Type : S6000 - 32-port TE/FG (SI) Current Type : S6000 - 32-port TE/FG (SI) Master priority : 0 Hardware Rev : 4.
Up Time : 21 min, 8 sec Dell Networking OS Version : 9-4(0-168) Jumbo Capable : yes POE Capable : no FIPS Mode : disabled Boot Flash : 3.1.1.2 Boot Selector : 3.1.0.
Auto Reboot Burned In MAC No Of MACs : disabled : 00:00:00:00:00:00 : 3 -- Power Supplies -Unit Bay Status Type FanStatus FanSpeed(rpm) --------------------------------------------------------------------------1 1 up AC up 18528 1 2 absent absent 0 -- Fan Status -Unit Bay TrayStatus Fan1 Speed Fan2 Speed -----------------------------------------------------------------------------------1 1 up up 19275 up 19275 1 2 absent 1 3 up up 19275 up 18904 Speed in RPM Related Commands • show version – displays t
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced save to the file options. 7.6.1.0 Introduced on the S-Series. Without the page or stack-unit option, the command output is continuous. To interrupt the command output, use Ctrl-z. The save option works with other filtering commands. This allows you to save specific information of a show command.
save Save output to a file Dell#show tech-support stack-unit 1 | save ? flash: Save to local file system (flash://filename (max 20 chars) ) Dell#show tech-support stack-unit 1 | save flash://LauraSave Start saving show command report ....... Dell# Dell#dir Directory of flash: 1 drw- 16384 Jan 01 1980 00:00:00 +00:00 . 2 drwx 1536 Jul 13 1996 02:38:06 +00:00 ..
hardware watchdog stack-unit 4 hardware watchdog stack-unit 5 ! Related Commands ssh-peer-stack-unit Open an SSH connection to the peer stack-unit. Syntax ssh-peer-stack-unit [-l username] Parameters Defaults -l username (OPTIONAL) Enter the keyword -l then your user name. The default is the user name associated with the terminal. Not configured. Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific.
Parameters host Enter the name of a server. ip-address Enter the IPv4 address in dotted decimal format of the server. ipv6-address prefixlength Enter the IPv6 address in the x:x:x:x::x format then the prefix length in the /x format. The range is from /0 to /128. NOTE: The :: notation specifies successive hexadecimal fields of zeros. Defaults Command Modes Command History vrf instance (Optional) Enter the keyword vrf then the VRF instance name.
Usage Information Version Description 7.9.1.0 Introduced VRF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series and added support for IPv6 address on the E-Series only. The VRF configured using this command has a higher precedence than a VRF configured using the ip telent vrf vrf-name command. If you do not use the VRF attribute in this command, then TELENT client uses the VRF configured using the ip telnet vrf vrf-name command.
terminal length Configure the number of lines displayed on the terminal screen. Syntax Parameters Defaults Command Modes Command History terminal length screen-length screen-length Enter a number of lines. Entering zero causes the terminal to display without pausing. The range is from 0 to 512. 24 lines • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Defaults Command Modes Command History • Timeout = 5 seconds • Probe count = 3 • 30 hops max • 40 byte packet size • UDP port = 33434 • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
2 gwegress-sjc-02.Dell Networking.com (10.11.30.126) 005.000 ms 001.000 ms 001.000 ms 3 fw-sjc-01.Dell Networking.com (10.11.127.254) 000.000 ms 000.000 ms 000.000 ms 4 www.Dell Networking.com (10.11.84.18) 000.000 ms 000.000 ms 000.000 ms FTOS# Example (IPv6) Dell#traceroute 100::1 Type Ctrl-C to abort. ----------------------------------------------Tracing the route to 100::1, 64 hops max, 60 byte packets ----------------------------------------------Hops Hostname Probe1 Probe2 Probe3 1 100::1 000.
Version Description 7.5.1.0 Introduced on the C-Series. E-Series Original command virtual-ip Configure a virtual IP address for the active management interface. You can configure virtual addresses both for IPv4 and IPv6 independently. Syntax virtual-ip {ipv4-address | ipv6-address} To return to the default, use the no virtual-ip {ipv4-address | ipv6-address} command. Parameters ipv4-address Enter the IP address of the active management interface in a dotted decimal format (A.B.C.D.).
write Copy the current configuration to either the startup-configuration file or the terminal. Syntax Parameters write {memory compressed| terminal} memory Enter the keyword memory to copy the current running configuration to the startup configuration file. This command is similar to the copy runningconfig startup-config command. compressed Enter the keyword compressed to write the operating configuration to the startup-config file in the compressed mode.
5 802.1X An authentication server must authenticate a client connected to an 802.1X switch port. Until the authentication, only extensible authentication protocol over LAN (EAPOL) traffic is allowed through the port to which a client is connected. After authentication is successful, normal traffic passes through the port. The Dell Networking operating software supports remote authentication dial-in service (RADIUS) and active directory environments using 802.1X Port Authentication.
interface interface Restricts the debugging information to an interface. Defaults Disabled Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.4.1.0 Introduced on the C-Series and S-Series. If the host responds to 802.1X with an incorrect login/password, the login fails. The switch attempts to authenticate again until the maximum attempts configured is reached. If the authentication fails after all allowed attempts, the interface moves to the authentication failed VLAN.
dot1x auth-type mab-only To authenticate a device with MAC authentication bypass (MAB), only use the host MAC address. Syntax dot1x auth-type mab-only Defaults Disabled Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000.
dot1x guest-vlan Configure a guest VLAN for limited access users or for devices that are not 802.1X capable. Syntax dot1x guest-vlan vlan-id To disable the guest VLAN, use the no dot1x guest-vlan vlan-id command. Parameters vlan-id Enter the VLAN Identifier. The range is from 1 to 4094. Defaults Not configured. Command Modes CONFIGURATION (conf-if-interface-slot/port) Command History This guide is platform-specific.
dot1x host-mode Enable single-host or multi-host authentication. Syntax dot1x host-mode {single-host | multi-host | multi-auth} Parameters single-host Enable single-host authentication. multi-host Enable multi-host authentication. multi-auth Enable multi-supplicant authentication. Defaults single-host Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Defaults Disabled Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.
Version Description 8.3.11.1 Introduced on the Z9000. 7.6.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series. dot1x max-supplicants Restrict the number of supplicants that can be authenticated and permitted to access the network through the port. This configuration is only takes effect in Multi-auth mode. Syntax dot1x max-supplicants number Parameters number Enter the number of supplicants that can be authenticated on a single port in Multi-auth mode.
force-unauthorized Enter the keywords force-unauthorized to forcibly de-authorize a port. Defaults none Command Modes Auto Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 9.0.0.
Version Description 8.3.12.0 Introduced on the S4810. 7.6.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series. dot1x reauthentication Enable periodic reauthentication of the client. Syntax dot1x reauthentication [interval seconds] To disable periodic reauthentication, use the no dot1x reauthentication command. Parameters interval seconds (Optional) Enter the keyword interval then the interval time, in seconds, after which reauthentication is initiated.
Parameters number Enter the permitted number of re-authentications. The range is from 1 to 10. The default is 2. Defaults 2 Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 9.0.0.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 7.6.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series. When you configure the dot1x server-timeout value, take into account the communication medium used to communicate with an authentication server and the number of RADIUS servers configured.
Version Description 8.3.11.1 Introduced on the Z9000. 7.6.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series. dot1x tx-period Configure the intervals at which EAPOL PDUs the Authenticator PAE transmits. Syntax dot1x tx-period seconds To return to the default, use the no dot1x tx-period command. Parameters seconds Enter the interval time, in seconds, that EAPOL PDUs are transmitted. The range is from 1 to 65535. The default is 30.
mac-address Defaults • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. (Optional) MAC address of an 802.1X-authenticated supplicant. none Command Modes Command History • EXEC • EXEC privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
802.1p CoS re-map table for Supplicant: 00:00:00:00:00:10 Dot1p 0 1 2 3 4 5 6 7 Dell# Remapped Dot1p 7 6 5 4 3 2 1 0 show dot1x interface Display the 802.1X configuration of an interface. Syntax Parameters show dot1x interface interface [mac-address mac-address] interface mac-address Defaults Command Modes Command History Enter one of the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
Usage Information If you enable 802.1X multi-supplicant authentication on a port, additional 802.1X configuration details (Port Authentication status, Untagged VLAN ID, Authentication PAE state, and Backend state) display for each supplicant, as shown in the following example. Example Dell#show dot1x interface tengigabitethernet 1/32 802.
Dell# show dot1x interface tengigabitethernet 1/32 mac-address 00:00:00:00:00:11 Supplicant Mac: 0 0 0 0 0 10 Lookup for Mac: 802.
00:00:00:00:00:11 Supplicant Mac: 0 0 0 0 0 10 Lookup for Mac: 802.
6 Access Control Lists (ACL) Access control lists (ACLs) are supported by the Dell Networking OS.
Command History • CONFIGURATION-EXTENDED-ACCESS-LIST • CONFIGURATION-MAC ACCESS LIST-STANDARD • CONFIGURATION-MAC ACCESS LIST-EXTENDED This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
• Command History CONFIGURATION-MAC ACCESS LIST-EXTENDED This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.11.1 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 8.1.
Defaults Not configured. Command Modes LINE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Added the ipv4 and ipv6 parameters to the command. Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.
Parameters access-list-name (OPTIONAL) Enter the name of a configured access-list, up to 140 characters. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
NOTE: When you specify a single VRF, use the name of the VRF instead of the VRF ID number. Use the VRF ID numbers only when you specify a range of VRFs. Defaults Not enabled. Command Modes INTERFACE/VRF MODE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.
ip control-plane egress-filter Enable egress Layer 3 ACL lookup for IPv4 CPU traffic. Syntax ip control-plane egress-filter Defaults Not enabled. Command Modes EXEC Privilege Command History Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. show ip accounting access-list Display the IP access-lists created on the switch and the sequence of filters.
Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for the 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced. show ip accounting access-lists Description “Extended IP...
deny To drop packets with a certain IP address, configure a filter. Syntax deny {source | any | host {ip-address}} [no-drop] To remove this filter, you have two choices: Parameters • Use the no seq sequence-number command if you know the filter’s sequence number. • Use the no deny {source [mask] | any | host ip-address} command. source Enter the IP address in dotted decimal format of the network from which the packet was sent.
Usage Information Version Description 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Added support for the non-contiguous mask and added the monitor option. 6.5.1.0 Expanded to include the optional QoS order priority for the ACL entry. The order option is relevant in the context of the Policy QoS feature only. For more information, refer to the Quality of Service chapter of the Dell Networking OS Configuration Guide.
Usage Information Version Description 7.4.1.0 Added support for the non-contiguous mask and added the monitor option. 6.5.1.0 Expanded to include the optional QoS order priority for the ACL entry. Dell Networking OS supports one ingress and one egress IP ACL per interface. Prior to Dell Networking OS version 7.8.1.0, names are up to 16 characters long. The number of entries allowed per ACL is hardware-dependent.
Defaults Not configured. Command Modes CONFIGURATION-STANDARD-ACCESS-LIST Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Added the no-drop parameter. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
host ip-address Enter the keyword host then the IP address to specify a host IP address or hostname. count (OPTIONAL) Enter the keyword count to count packets the filter processes. bytes (OPTIONAL) Enter the keyword bytes to count bytes the filter processes. dscp (OPTIONAL) Enter the keyword dcsp to match to the IP DCSCP values. order (OPTIONAL) Enter the keyword order to specify the QoS order for the ACL entry.
• Related Commands If you configure sequence-number, the sequence-number is used as a tie breaker for rules with the same order. deny — configures a filter to drop packets. permit — configures a filter to forward packets. Extended IP ACL Commands When an ACL is created without any rule and then applied to an interface, ACL behavior reflects an implicit permit. The following commands configure extended IP ACLs, which in addition to the IP address, also examine the packet’s protocol type.
order (OPTIONAL) Enter the keyword order to specify the QoS priority for the ACL entry. The range is from 0 to 254 (where 0 is the highest priority and 254 is the lowest; lower-order numbers have a higher priority). If you do not use the keyword order, the ACLs have the lowest order by default (255). monitor (OPTIONAL) Enter the keyword monitor when the rule is describing the traffic that you want to monitor and the ACL in which you are creating the rule is applied to the monitored interface.
The C-Series and S-Series cannot count both packets and bytes, when you enter the count byte options, only bytes are incremented. NOTE: When you configure ACL logging and byte counters simultaneously, byte counters may display an incorrect value. Configure packet counters with logging instead. Related Commands deny tcp — assigns a filter to deny TCP packets. deny udp — assigns a filter to deny UDP packets. ip access-list extended — creates an extended ACL.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Added the no-drop parameter. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Added the keyword dscp. 8.2.1.0 Allows ACL control of fragmented packets for IP (Layer 3) ACLs. 8.1.1.0 Introduced on the E-Series ExaScale. 7.4.1.
operator port port • psh: push function • rst: reset the connection • syn: synchronize sequence numbers • urg: urgent field (OPTIONAL) Enter one of the following logical operand: • eq = equal to • neq = not equal to • gt = greater than • lt = less than • range = inclusive range of ports (you must specify two ports for the port command) Enter the application layer port number. Enter two port numbers if using the range logical operand. The range is from 0 to 65535.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Added the keyword dscp. 8.2.1.0 Allows ACL control of fragmented packets for IP (Layer 3) ACLs. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Added support for non-contiguous mask and added the monitor option. Deprecated the keyword established. 6.5.1.
Related Commands deny — assigns a filter to deny IP traffic. deny udp — assigns a filter to deny UDP traffic. deny udp To drop user datagram protocol (UDP) packets meeting the filter criteria, configure a filter.
no-drop Enter the keywords no-drop to match only the forwarded packets. Defaults Not configured. Command Modes CONFIGURATION-EXTENDED-ACCESS-LIST Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Added the no-drop parameter. 9.7(0.
4 5 6 7 8 0001100000000000 0001110000000000 0001111000000000 0001111100000000 0001111101000000 1111110000000000 1111111000000000 1111111100000000 1111111111000000 1111111111111111 6144 7168 7680 7936 8000 7167 7679 7935 7999 8000 1024 512 256 64 1 Total Ports: 4001 Example An ACL rule with a TCP port lt 1023 uses only one entry in the CAM.
Usage Information The number of entries allowed per ACL is hardware-dependent. For detailed specification about entries allowed per ACL, refer to your line card documentation. Prior to 7.8.1.0, names are up to 16 characters long. Example Dell(conf)#ip access-list extended TESTListEXTEND Dell(config-ext-nacl)# Related Commands ip access-list standard — configures a standard IP access list. show config — displays the current configuration.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Added the no-drop parameter. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Add the DSCP value for ACL matching. 8.2.1.0 Allows ACL control of fragmented packets for IP (Layer 3) ACLs. 8.1.1.
any Enter the keyword any to specify that all routes are subject to the filter. host ip-address Enter the keyword host then the IP address to specify a host IP address. bit Enter a flag or combination of bits: • ack: acknowledgement field • fin: finish (no more data from the user) • psh: push function • rst: reset the connection • syn: synchronize sequence numbers • urg: urgent field dscp Enter the keyword dscp to deny a packet based on the DSCP value. The range is from 0 to 63.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Added the no-drop parameter. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Total Ports: 4001 Example An ACL rule with a TCP port lt 1023 uses only one entry in the CAM. Rule# Data Mask From To 1 0000000000000000 1111110000000000 0 #Covered 1023 1024 Total Ports: 1024 Related Commands ip access-list extended — creates an extended ACL. permit — assigns a permit filter for IP packets. permit udp — assigns a permit filter for UDP packets. permit udp To pass UDP packets meeting the filter criteria, configure a filter.
count (OPTIONAL) Enter the keyword count to count packets processed by the filter. byte (OPTIONAL) Enter the keyword byte to count bytes processed by the filter. order (OPTIONAL) Enter the keyword order to specify the QoS priority for the ACL entry. The range is from 0 to 254 (where 0 is the highest priority and 254 is the lowest; lower-order numbers have a higher priority). If you do not use the keyword order, the ACLs have the lowest order by default (255).
Most ACL rules require one entry in the CAM. However, rules with TCP and UDP port operators (for example, gt, lt, or range) may require more than one entry. The range of ports is configured in the CAM based on bit mask boundaries; the space required depends on exactly what ports are included in the range. Example An ACL rule with a TCP port range of 4000–8000 uses eight entries in the CAM.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale (IPv4). 7.8.1.0 Increased the name string to accept up to 140 characters. Prior to 7.8.1.0, names were up to 16 characters long. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.
operator port port (OPTIONAL) Enter one of the following logical operands: • eq = equal to • neq = not equal to • gt = greater than • lt = less than • range = inclusive range of ports (you must specify two ports for the port parameter.) (OPTIONAL) Enter the application layer port number. Enter two port numbers if you are using the range logical operand. The range is from 0 to 65535.
Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Add the DSCP value for ACL matching. 8.2.1.0 Allows ACL control of fragmented packets for IP (Layer 3) ACLs. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.
Common MAC Access List Commands The following commands are available within both MAC ACL modes (Standard and Extended) and do not have mode-specific options. These commands allow you to clear, display, and assign MAC ACL configurations. The platform supports both Ingress and Egress MAC ACLs. The MAC ACL can be applied on Physical, Port-channel and VLAN interfaces. As per the specified rules in the ACL, the traffic on the interface/ VLAN members or Port-channel members will be permitted or denied.
NOTE: This option is available only with the keywordin option. in Enter the keyword in to configure the ACL to filter incoming traffic. out Enter the keyword out to configure the ACL to filter outgoing traffic. NOTE: The option is not available on the S-Series. NOTE: 1. If the MAC ACL is applied on VLAN, none of the VLAN members should have an access list applied for that VLAN. 2.
show mac access-lists Display all of the Layer 2 ACLs configured in the system, whether or not they are applied to an interface, and the count of matches/ mismatches against each ACL entry displayed. Syntax show mac access-lists [access-list-name] [interface interface] [in | out] Parameters access-list-name Enter the name of a configured MAC ACL, up to 140 characters.
in | out Command Modes Command History • EXEC • EXEC Privilege • For a port channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. Identify whether ACL is applied on ingress or egress side. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
deny To drop packets with a the MAC address specified, configure a filter. Syntax deny {any | mac-source-address [mac-source-address-mask]} [count [byte]] [log] [monitor] To remove this filter, you have two choices: Parameters • Use the no seq sequence-number command if you know the filter’s sequence number. • Use the no deny {any | mac-source-address mac-source-address-mask} command. any Enter the keyword any to specify that all routes are subject to the filter.
Usage Information When you use the log option, the CP processor logs detail the packets that match. Depending on how many packets match the log entry and at what rate, the CP may become busy as it has to log these packets’ details. NOTE: When you configure ACL logging and byte counters simultaneously, byte counters may display an incorrect value. Configure packet counters with logging instead. Related Commands permit — configures a MAC address filter to pass packets.
NOTE: Ingress ACLs are supported on C-Series and S-Series platforms only. Example Dell(conf)#mac-access-list access-list standard TestMAC Dell(config-std-macl)#permit 00:00:00:00:00:00 00:00:00:00:ff:ff count Dell(config-std-macl)#deny any count permit To forward packets from a specific source MAC address, configure a filter.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series. When you use the log option, the CP processor logs details about the packets that match. Depending on how many packets match the log entry and at what rate, the CP may become busy as it has to log these packets’ details.
NOTE: For more information, refer to the “Flow-based Monitoring” section in the Port Monitoring chapter of the Dell Networking OS Configuration Guide. no-drop Enter the keywords no-drop to match only the forwarded packets. Defaults Not configured Command Modes CONFIGURATION-MAC ACCESS LIST-STANDARD Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
NOTE: For more information, also refer to the Commands Common to all ACL Types and Common MAC Access List Commands sections. deny To drop packets that match the filter criteria, configure a filter.
Monitoring” section in the Port Monitoring chapter of the Dell Networking OS Configuration Guide. Defaults Not configured. Command Modes CONFIGURATION-MAC ACCESS LIST-EXTENDED Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.10.0 Introduced on the S4810. 8.1.
permit To pass packets matching the criteria specified, configure a filter. Syntax permit {any | host mac-address | mac-source-address mac-source-addressmask} {any | host mac-address | mac-destination-address mac-destinationaddress-mask} [ethertype operator] [count [byte]] | [log] [monitor] To remove this filter, you have two choices: Parameters • Use the no seq sequence-number command if you know the filter’s sequence number.
NOTE: For more information, refer to the Flow-based Monitoring section in the Port Monitoring chapter of the Dell Networking OS Configuration Guide. Defaults Not configured. Command Modes CONFIGURATION-MAC ACCESS LIST-EXTENDED Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Parameters prefix-name (OPTIONAL) Enter the name of the configured prefix list to clear only counters for that prefix list, up to 140 characters long. Defaults Clears “hit” counters for all prefix lists unless a prefix list is specified. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series.
Version Description 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. Usage Information Prefix lists redistribute OSPF and RIP routes meeting specific criteria. Related Commands show ip route list — displays IP routes in an IP prefix list. show ip prefix-list summary — displays a summary of the configured prefix lists. seq To a deny or permit filter in a prefix list while configuring the filter, assign a sequence number.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.3.1.0 Added the bit mask option. If you do not use the ge or le options, only packets with an exact match to the prefix are filtered. show config Display the current PREFIX-LIST configurations.
Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.
Example Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Increased the name string to accept up to 140 characters. Prior to 7.8.1.0, names are up to 16 characters long. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series.
Usage Information Version Description 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series. The continue feature allows movement from one route-map entry to a specific route-map entry (the sequence number). If you do not specify the sequence number, the continue feature simply moves to the next sequence number (also known as an implied continue).
Command Modes ROUTE-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.
Related Commands Version Description 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. set as-path — adds information to the BGP AS_PATH attribute. match community To match routes that have a certain COMMUNITY attribute in their BGP path, configure a filter. Syntax match community community-list-name [exact] To delete a community match filter, use the no match community command. Parameters community-listname Enter the name of a configured community list.
Parameters interface Enter the following keywords and slot/port or number information: • . • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383. • For a port channel interface, enter the keywords port-channel then a number. The range is from 1 to 128.
match ip address To match routes based on IP addresses specified in an access list, configure a filter. Syntax match ip address prefix-list-name To delete a match, use the no match ip address prefix-list-name command. Parameters prefix-list-name Enter the name of configured prefix list, up to 140 characters. Defaults Not configured. Command Modes ROUTE-MAP Command History This guide is platform-specific.
To delete a match, use the no match ip next-hop {prefix-list prefix-list-name} command. Parameters prefix-list prefix-listname Enter the keywords prefix-list and then enter the name of configured prefix list, up 10 140 characters. Defaults Not configured. Command Modes ROUTE-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Parameters prefix-list prefix-listname Enter the keywords prefix-list and then enter the name of configured prefix list, up to 140 characters. Defaults Not configured. Command Modes ROUTE-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.
Command Modes ROUTE-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. pre-6.1.1.0 Introduced on the E-Series. match route-type To match routes based on the how the route is defined, configure a filter.
Related Commands Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. match interface — redistributes routes that match the next-hop interface. match ip address — redistributes routes that match an IP address. match ip next-hop — redistributes routes that match the next-hop IP address. match ip route-source — redistributes routes that match routes advertised by other routers.
Related Commands match interface — redistributes routes that match the next-hop interface. match ip address — redistributes routes that match an IP address. match ip next-hop — redistributes routes that match the next-hop IP address. match ip route-source — redistributes routes that match routes advertised by other routers. match metric — redistributes routes that match a specific metric. match route-type — redistributes routes that match a route type.
Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. Usage Information Use caution when you delete route maps because if you do not specify a sequence number, all route maps with the same map-name are deleted when you use the no route-map map-name command. Example Dell(conf)#route-map dempsey Dell(config-route-map)# Related Commands show config — displays the current configuration.
Related Commands match as-path — redistributes routes that match an AS-PATH attribute. set automatic-tag To automatically compute the tag value of the route, configure a filter. Syntax set automatic-tag To return to the default, enter no set automatic-tag. Defaults Not configured. Command Modes ROUTE-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Defaults Not configured. Command Modes ROUTE-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
All routes with the NO_EXPORT_SUBCONFED (0xFFFFFF03) community attribute must not be advertised to external BGP peers. no-advertise Enter the keywords no-advertise to drop all routes containing the well-known community attribute of NO_ADVERTISE. All routes with the NO_ADVERTISE (0xFFFFFF02) community attribute must not be advertised to other BGP peers. no-export Enter the keywords no-export to drop all routes containing the well-known community attribute of NO_EXPORT.
Parameters backbone Enter the keyword backbone to redistribute matched routes to the OSPF backbone area (area 0.0.0.0). level-1 Enter the keyword level-1 to redistribute matched routes to IS-IS Level 1. level-1-2 Enter the keyword level-1-2 to redistribute matched routes to IS-IS Level 1 and Level 2. level-2 Enter the keyword level-2 to redistribute matched routes to IS-IS Level 2. stub-area Enter the keyword stub to redistributed matched routes to OSPF stub areas. Defaults Not configured.
Defaults Not configured. Command Modes ROUTE-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.
Related Commands Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. set automatic-tag — computes the tag value of the route. set level — specifies the OSPF area for route redistribution.
Related Commands Version Description 8.3.7.0 Introduced on the S4810. 8.3.1.0 Implemented the keyword internal. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. set automatic-tag — computes the tag value of the route. set level — specifies the OSPF area for route redistribution. set metric — specifies the metric value assigned to redistributed routes.
Usage Information If you configure the set next-hop command, its configuration takes precedence over the neighbor next-hop-self command in the ROUTER BGP mode. If you configure the set next-hop command with the interface’s IP address (either Loopback or physical), the software declares the route unreachable. Related Commands match ip next-hop — redistributes routes that match the next-hop IP address. set origin To manipulate the BGP ORIGIN attribute, configure a filter.
To delete a setting, use the no set tag command. Parameters tag-value Enter a number as the tag. The range is from zero (0) to 4294967295. Defaults Not configured. Command Modes ROUTE-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.
Defaults Not configured. Command Modes ROUTE-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Example Dell(conf-nprefixl)#show config ! ip prefix-list PL_OSPF_to_RIP seq 5 permit 1.1.1.0/24 seq 10 deny 2.1.0.0/16 ge 23 seq 25 permit 192.0.0.0 bitmask 192.0.0.0 show route-map Display the current route map configurations. Syntax show route-map [map-name] Parameters Command Modes Command History map-name • EXEC • EXEC Privilege (OPTIONAL) Enter the name of a configured route map, up to 140 characters. This guide is platform-specific.
UDF ACL Commands The following commands are available within each UDF ACL mode. deny ip Disassociate the UDF in IP access-list. Syntax deny ip {source mask | any | host ip-address} {destination mask | any | host ip-address} udf-pkt-format name udf-qualifier-value name To remove this filter, use the no seq sequence-number command. Parameters Command Modes source Enter the IP address of the network or host from which the packets were sent. mask Enter a network mask in /prefix format (/x) or A.B.C.D.
To disable the udf-acl feature, use the no feature udf-acl command. Defaults Disabled Command Modes CONFIGURATION Example Dell(conf)#feature udf-acl Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S6000, Z9500.
The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.8(0.0) Introduced on the S6000, Z9500. udf-tcam — creates a context for UDF TCAM. show config — displays the current UDF TCAM profile configuration. match Configure the packet type to match for which the UDF offset bytes have to be parsed.
Related Commands udf-tcam — creates a context for UDF TCAM. show config — displays the current UDF TCAM profile configuration. permit ip Associate the UDF in IP access-list. Syntax permit ip {source mask | any | host ip-address} {destination mask | any | host ip-address} udf-pkt-format name udf-qualifier-value name To remove this filter, use the no seq sequence-number command. Parameters Command Modes source Enter the IP address of the network or host from which the packets were sent.
Command Modes CONFIGURATION-UDF TCAM Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.8(0.0) Introduced on the S6000, Z9500.
udf-qualifier-value Create a UDF qualifier value to assign values for all UDF IDs. Syntax udf-qualifier-value name To return to the default settings, use the no udf-qualifier-value name command. Parameters name Enter the UDF qualifier value profile name, up to 64 characters. Defaults None Command Modes CONFIGURATION-UDF TCAM Example Dell(conf-udf-tcam)# udf-qualifier-value ipnip_val1 Command History This guide is platform-specific.
Version Description 9.8(0.0) Introduced on the S6000, Z9500. deny (for Standard IP ACLs) To drop packets with a certain IP address, configure a filter. Syntax deny {source | any | host {ip-address}}[count [byte]] [dscp value] [order] [fragments] [log [interval minutes] [threshold-in-msgs [count]] [monitor] To remove this filter, you have two choices: Parameters Defaults • Use the no seq sequence-number command if you know the filter’s sequence number.
If ACL logging is stopped because the configured threshold is exceeded, it is re-enabled after the logging interval period elapses. ACL logging is supported for standard and extended IPv4 ACLs, IPv6 ACLs, and MAC ACLs. You can configure ACL logging only on ACLs that are applied to ingress interfaces; you cannot enable logging for ACLs that are associated with egress interfaces.
The default frequency at which ACL logs are generated is five minutes. By default, flow-based monitoring is not enabled. Command Modes Command History Usage Information CONFIGURATION-EXTENDED-ACCESS-LIST Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4(0.0) Added support for flow-based monitoring on the S4810, S4820T, S6000, and Z9000 platforms. 9.3(0.0) Added support for logging of ACLs on the S4810, S4820T, and Z9000 platforms.
Defaults threshold-in msgs count (OPTIONAL) Enter the threshold-in-msgs keyword followed by a value to indicate the maximum number of ACL logs that can be generated, exceeding which the generation of ACL logs is terminated with the seq, permit, or deny commands. The threshold range is from 1 to 100. interval minutes (OPTIONAL) Enter the keyword interval followed by the time period in minutes at which ACL logs must be generated. The interval range is from 1 to 10 minutes.
deny tcp (for Extended IP ACLs) Configure a filter that drops transmission control protocol (TCP) packets meeting the filter criteria.
You can activate flow-based monitoring for a monitoring session by entering the flow-based enable command in the Monitor Session mode. When you enable this capability, traffic with particular flows that are traversing through the ingress and egress interfaces are examined and, appropriate ACLs can be applied in both the ingress and egress direction. Flow-based monitoring conserves bandwidth by monitoring only specified traffic instead all traffic on the interface.
Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4(0.0) Added support for flow-based monitoring on the S4810, S4820T, S6000, and Z9000 platforms. 9.3(0.0) Added support for logging of ACLs on the S4810, S4820T, and Z9000 platforms. When the configured maximum threshold is exceeded, generation of logs is stopped.
monitor Defaults (OPTIONAL) Enter the keyword monitor when the rule is describing the traffic that you want to monitor and the ACL in which you are creating the rule is applied to the monitored interface. By default, 10 ACL logs are generated if you do not specify the threshold explicitly. The default frequency at which ACL logs are generated is five minutes. By default, flow-based monitoring is not enabled.
To remove this filter, you have two choices: Parameters Defaults • Use the no seq sequence-number command if you know the filter’s sequence number. • Use the no deny {any | host mac-address | mac-source-address mac-sourceaddress-mask} {any | host mac-address | mac-destination-address macdestination-address-mask} command. log (OPTIONAL) Enter the keyword log to enable the triggering of ACL log messages.
forwards (mirrors) them to another port. The source port is the monitored port (MD) and the destination port is the monitoring port (MG). Related Commands permit — configures a MAC address filter to pass packets. seq — configures a MAC address filter with a specified sequence number. permit (for Standard IP ACLs) To permit packets from a specific source IP address to leave the switch, configure a filter.
packet count for that new interval commences from zero. If ACL logging was stopped previously because the configured threshold is exceeded, it is re-enabled for this new interval. If ACL logging is stopped because the configured threshold is exceeded, it is re-enabled after the logging interval period elapses. ACL logging is supported for standard and extended IPv4 ACLs, IPv6 ACLs, and MAC ACLs.
The default frequency at which ACL logs are generated is five minutes. By default, flow-based monitoring is not enabled. Command Modes Command History Usage Information CONFIGURATION-EXTENDED-ACCESS-LIST Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4(0.0) Added support for flow-based monitoring on the S4810, S4820T, S6000, and Z9000 platforms. 9.3(0.0) Added support for logging of ACLs on the S4810, S4820T, and Z9000 platforms.
Defaults threshold-in msgs count (OPTIONAL) Enter the threshold-in-msgs keyword followed by a value to indicate the maximum number of ACL logs that can be generated, exceeding which the generation of ACL logs is terminated. with the seq, permit, or deny commands. The threshold range is from 1 to 100. interval minutes (OPTIONAL) Enter the keyword interval followed by the time period in minutes at which ACL logs must be generated. The interval range is from 1 to 10 minutes.
permit icmp (for Extended IP ACLs) Configure a filter to allow all or specific ICMP messages. Syntax permit icmp {source mask | any | host ip-address} {destination mask | any | host ip-address} [dscp] [message-type] [count [byte]] [order] [fragments] [log [interval minutes] [threshold-in-msgs [count]] [monitor] To remove this filter, you have two choices: Parameters Defaults • Use the no seq sequence-number command if you know the filter’s sequence number.
traversing through the ingress and egress interfaces are examined and, appropriate ACLs can be applied in both the ingress and egress direction. Flow-based monitoring conserves bandwidth by monitoring only specified traffic instead all traffic on the interface. This feature is particularly useful when looking for malicious traffic. It is available for Layer 2 and Layer 3 ingress and egress traffic. You may specify traffic using standard or extended access-lists.
Usage Information When the configured maximum threshold is exceeded, generation of logs is stopped. When the interval at which ACL logs are configured to be recorded expires, the subsequent, fresh interval timer is started and the packet count for that new interval commences from zero. If ACL logging was stopped previously because the configured threshold is exceeded, it is re-enabled for this new interval.
monitor Defaults (OPTIONAL) Enter the keyword monitor when the rule is describing the traffic that you want to monitor and the ACL in which you are creating the rule is applied to the monitored interface. By default, 10 ACL logs are generated if you do not specify the threshold explicitly. The default frequency at which ACL logs are generated is five minutes. By default, flow-based monitoring is not enabled.
permit (for Standard MAC ACLs) To forward packets from a specific source MAC address, configure a filter. Syntax permit {any | mac-source-address [mac-source-address-mask]} [count [byte]] | [log [interval minutes] [threshold-in-msgs [count]] [monitor] To remove this filter, you have two choices: Parameters Defaults • Use the no seq sequence-number command if you know the filter’s sequence number. • Use the no permit {any | mac-source-address mac-source-address-mask} command.
malicious traffic. It is available for Layer 2 and Layer 3 ingress and egress traffic. You may specify traffic using standard or extended access-lists. This mechanism copies all incoming or outgoing packets on one port and forwards (mirrors) them to another port. The source port is the monitored port (MD) and the destination port is the monitoring port (MG). Related Commands deny — configures a MAC ACL filter to drop packets. seq —configure a MAC ACL filter with a specified sequence number.
packet count for that new interval commences from zero. If ACL logging was stopped previously because the configured threshold is exceeded, it is re-enabled for this new interval. If ACL logging is stopped because the configured threshold is exceeded, it is re-enabled after the logging interval period elapses. ACL logging is supported for standard and extended IPv4 ACLs, IPv6 ACLs, and MAC ACLs.
The default frequency at which ACL logs are generated is five minutes. By default, flow-based monitoring is not enabled. Command Modes Command History Usage Information CONFIGURATION-EXTENDED-ACCESS-LIST Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4(0.0) Added support for flow-based monitoring on the S4810, S4820T, S6000, and Z9000 platforms. 9.3(0.0) Added support for logging of ACLs on the S4810, S4820T, and Z9000 platforms.
To remove this filter, use the no seq sequence-number command. Parameters Defaults log (OPTIONAL) Enter the keyword log to enable the triggering of ACL log messages. threshold-in msgs count (OPTIONAL) Enter the threshold-in-msgs keyword followed by a value to indicate the maximum number of ACL logs that can be generated, exceeding which the generation of ACL logs is terminated. with the seq, permit, or deny commands. You can enter a threshold in the range of 1-100.
seq ether-type (for Extended MAC ACLs) Configure an egress filter with a specific sequence number that filters traffic with specified types of Ethernet packets. This command is supported only on 12-port GE line cards with SFP optics. For specifications, refer to your line card documentation. NOTE: Only the options that have been newly introduced in Release 9.3(0.0) and Release 9.4(0.0) are described here.
that are applied to ingress interfaces; you cannot enable logging for ACLs that are associated with egress interfaces. You can activate flow-based monitoring for a monitoring session by entering the flow-based enable command in the Monitor Session mode. When you enable this capability, traffic with particular flows that are traversing through the ingress and egress interfaces are examined and, appropriate ACLs can be applied in both the ingress and egress direction.
Usage Information When the configured maximum threshold is exceeded, generation of logs is stopped. When the interval at which ACL logs are configured to be recorded expires, the subsequent, fresh interval timer is started and the packet count for that new interval commences from zero. If ACL logging was stopped previously because the configured threshold is exceeded, it is re-enabled for this new interval.
The default frequency at which ACL logs are generated is five minutes. By default, flow-based monitoring is not enabled. Command Modes Command History Usage Information ACCESS-LIST Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4(0.0) Added support for flow-based monitoring on the S4810, S4820T, S6000, and Z9000 platforms. 9.3(0.0) Added support for logging of ACLs on the S4810, S4820T, and Z9000 platforms.
Defaults threshold-in msgs count (OPTIONAL) Enter the threshold-in-msgs keyword followed by a value to indicate the maximum number of ACL logs that can be generated, exceeding which the generation of ACL logs is terminated with the seq, permit, or deny commands. The threshold range is from 1 to 100. interval minutes (OPTIONAL) Enter the keyword interval followed by the time period in minutes at which ACL logs must be generated. The interval range is from 1 to 10 minutes.
permit tcp (for IPv6 ACLs) Configure a filter to pass TCP packets that match the filter criteria. Syntax permit tcp {source address mask | any | host ipv6-address} [operator port [port]] {destination address | any | host ipv6-address} [bit] [operator port [port]] [count [byte]] [log [interval minutes] [threshold-in-msgs [count]] [monitor] To remove this filter, you have two choices: Parameters Defaults • Use the no seq sequence-number command if you know the filter’s sequence number.
You can activate flow-based monitoring for a monitoring session by entering the flow-based enable command in the Monitor Session mode. When you enable this capability, traffic with particular flows that are traversing through the ingress and egress interfaces are examined and, appropriate ACLs can be applied in both the ingress and egress direction. Flow-based monitoring conserves bandwidth by monitoring only specified traffic instead all traffic on the interface.
Usage Information Version Description 9.4(0.0) Added support for flow-based monitoring on the S4810, S4820T, S6000, and Z9000 platforms. 9.3(0.0) Added support for logging of ACLs on the S4810, S4820T, and Z9000 platforms. When the configured maximum threshold is exceeded, generation of logs is stopped. When the interval at which ACL logs are configured to be recorded expires, the subsequent, fresh interval timer is started and the packet count for that new interval commences from zero.
no-drop Defaults Enter the keywords no-drop to match only the forwarded packets. By default, 10 ACL logs are generated if you do not specify the threshold explicitly. The default frequency at which ACL logs are generated is five minutes. By default, flow-based monitoring is not enabled. Command Modes Command History Usage Information ACCESS-LIST Version Description 9.8(0.0) Added the no-drop parameter. 9.7(0.0) Introduced on the S6000–ON. 9.4(0.
• Parameters Defaults Use the no deny udp {source address mask | any | host ipv6-address} {destination address | any | host ipv6-address} command log (OPTIONAL) Enter the keyword log to enable the triggering of ACL log messages. threshold-in msgs count (OPTIONAL) Enter the threshold-in-msgs keyword followed by a value to indicate the maximum number of ACL logs that can be generated, exceeding which the generation of ACL logs is terminated. with the seq, permit, or deny commands.
deny arp (for Extended MAC ACLs) Configure an egress filter that drops ARP packets on egress ACL supported line cards. (For more information, refer to your line card documentation).
You can activate flow-based monitoring for a monitoring session by entering the flow-based enable command in the Monitor Session mode. When you enable this capability, traffic with particular flows that are traversing through the ingress and egress interfaces are examined and, appropriate ACLs can be applied in both the ingress and egress direction. Flow-based monitoring conserves bandwidth by monitoring only specified traffic instead all traffic on the interface.
Usage Information Version Description 9.3(0.0) Added support for logging of ACLs on the S4810, S4820T, and Z9000 platforms. When the configured maximum threshold is exceeded, generation of logs is stopped. When the interval at which ACL logs are configured to be recorded expires, the subsequent, fresh interval timer is started and the packet count for that new interval commences from zero.
monitor Defaults (OPTIONAL) Enter the keyword monitor when the rule is describing the traffic that you want to monitor and the ACL in which you are creating the rule is applied to the monitored interface. By default, 10 ACL logs are generated if you do not specify the threshold explicitly. The default frequency at which ACL logs are generated is 5 minutes. By default, flow-based monitoring is not enabled. Command Modes Command History Usage Information ACCESS-LIST Version Description 9.7(0.
Parameters Defaults log (OPTIONAL) Enter the keyword log to enable the triggering of ACL log messages. threshold-in msgs count (OPTIONAL) Enter the threshold-in-msgs keyword followed by a value to indicate the maximum number of ACL logs that can be generated, exceeding which the generation of ACL logs is terminated. with the seq, permit, or deny commands. The threshold range is from 1 to 100.
7 Bidirectional Forwarding Detection (BFD) Bidirectional forwarding detection (BFD) is a detection protocol that provides fast forwarding path failure detection.
ROUTER ISIS Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 9.2.(0.0) Introduced BFD for VRRP and OSPFv3 on Z9000, S4810, and S4820T. 9.0.0.0 Introduced BFD for BGP on the Z9000. 8.3.19.
To disable BFD for all neighbors configured through static routes, use the no ip route bfd [interval interval min_rx min_rx multiplier value role {active | passive}] command. Parameters interval milliseconds (OPTIONAL) Enter the keywords interval to specify non-default BFD session parameters beginning with the transmission interval. The range is from 50 to 1000. The default is 100.
peer-group-name Enter the name of the peer group that you want to explicitly enable for BFD sessions. Defaults none Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.
Defaults none Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.8.
8 Boot Command Line Interface To access this BOOT_USER mode, first boot your Dell Networking platform. When you see the “Press ESC to stop auto-boot”, press the ESC key to log into BCLI You enter BOOT_USER mode immediately, as indicated by the BOOT_USER# prompt. NOTE: All commands in this chapter are in Boot_User mode. These commands are supported on the Dell Networking platform. You cannot use the Tab key to complete commands in this mode.
Note: You must set the IP address of the designated download port before you execute this command. Otherwise, an second statement message alerts you that the configuration cannot proceed. shows the first field after you enter boot change primary. At this point: Example • Press Enter to accept the information already configured, or • Change that information. To do so, press the . (period) key and enter new information. After you enter the information, press Enter.
boot show net config retries Show the number of retries for network boot configuration failure. S6000 Syntax boot show net config retries Command Modes BOOT_USER Command History Example Version 9.0.2.0 Introduced on the S6000. BOOT_USER #boot show net config retries Number of Network Boot Config Retries is : 0 BOOT_USER # boot write net config retries Set the number of retries for network boot configuration failure.
default Defaults None Command Modes BOOT_USER Command History Usage Information Version 9.0.2.0 Enter the keyword default to configure boot parameters used if the secondary operating system boot parameter selection is not available. You can configure this option to any of the available type, for example flash/usb/ftp/tftp. Introduced on the S6000. This command reverses changes made with the boot change command.
Parameters Command Modes Command History ip-address Enter the IP address of the gateway router in dotted decimal format (A.B.C.D). BOOT_USER Version 9.0.2.0 Introduced on the S6000. Usage Information Use the show default-gateway command to view the current default gateway. Related Commands show_default-gateway— Change the primary, secondary, or default boot image configuration. etheraddr Assign the management port MAC address.
Usage Information When you enter the reload command and the system reboots, you will not be prompted for a password to enter the EXEC Privilege mode (normally you are required to enter the enable command). If your console or Telnet session expires after you used the ignore enable-password command, you are prompted for an enable password when you re-establish the session Related Commands reload — Exit from this mode and reload FTOS.
show_interface_mangement_ethernet— Display the IP address configured for the Management interface. NVRAM erase Erase all NVRAM contents alone. S6000 Syntax Parameters Command Modes Command History nvram erase mac-address Enter a MAC address in standard format. BOOT_ADMIN Version 9.0.2.0 Introduced on the S6000. Usage Information Use this command to assign a MAC address if FTOS cannot find a default MAC address.
Parameters serial console [unit] [baud] Enter the keyword to set the serial port baud rate. The supported values for serial console: • Unit - 0 • Baud rate -9600,115200 No defaults. Command Modes Command History Example Serial BOOT_USER Version 9.0.2.0 Introduced on the S6000. BOOT_USER # serial console 0 9600 BOOT_USER # BOOT_USER # show bootvar Display boot configuration information. S6000 Syntax show bootvar Command Modes BOOT_USER Command History Example Version 9.0.2.
file name : PS-SI-9-0-0-566.bin Management Etherenet IP address : 10.16.133.17 Mask : 255.255.0.0 Server IP address : 10.16.1.200 Default Gateway IP address : 10.16.1.254 BOOT_USER # Related Commands boot_change— Change the primary, secondary, or default boot image configuration. boot_zero — Erase the configured primary, secondary, or default boot image parameters. show default-gateway Display the IP address configured for the default gateway.
Example BOOT_USER # show interfaces management ethernet Management ethernet IP address: 10.16.133.17/24 BOOT_ADMIN # On the S6000, the output of this command includes the MAC address and port number of the assigned management port. Example BOOT_ADMIN # show int man eth Management ethernet IP address: 10.16.132.4/16 BOOT_ADMIN # Related Commands interface_management_ethernet_ip_address — Assign an IP address to the Management Ethernet interface.
settimeout Enter the keyword set timeout to set timeout. NOTE: By default, watchdog is disabled. Command Modes Command History Example BOOT_ADMIN Version 9.0.2.0 Introduced on the S6000.
9 Border Gateway Protocol BGP is an external gateway protocol that transmits interdomain routing information within and between autonomous systems (AS). BGP version 4 (BGPv4) supports classless inter-domain routing (CIDR) and the aggregation of routes and AS paths. Basically, two routers (called neighbors or peers) exchange information including full routing tables and periodically sent messages to update those routing tables. BGP is supported in Dell Networking OS version 9.0.2.
NOTE: Use this attribute to start a BGP instance corresponding to either a specific address family in a default VRF or an IPv4 address family in a nondefault VRF. ipv6 unicast Enter the keyword ipv6 followed by the keyword unicast to enable BGPv6 mode. vrf vrf-name (Optional) Enter the keyword vrf followed by the name of the VRF to install the IPv6 route in that VRF. NOTE: It will not be possible to enable VRF mode for IPv6 unicast without configuring the corresponding IPv4 unicast mode for the same VRF.
AS_SET includes AS_PATH and community information from the routes included in the aggregated route. Defaults attribute-map mapname (OPTIONAL) Enter the keywords attribute-map then the name of a configured route map to modify attributes of the aggregate, excluding AS_PATH and NEXT_HOP attributes. summary-only (OPTIONAL) Enter the keyword summary-only to advertise only the aggregate address. Specific routes are not advertised.
When an aggregate address is denied using a peer's outbound route-map, individual routes suppressed by the aggregate address are advertised to that peer. The attribute-map corresponding to an aggregate address is applied during the outbound update creation time; hence the value set in that attribute-map will not be shown in the output of the show ip bgp aggregate route command.
To disable comparison of MED, enter no bgp always-compare-med. Defaults Disabled (that is, the software only compares MEDs from neighbors within the same AS). Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.
Usage Information Version Description 8.3.1.0 Introduced the dynamic application of AS notation changes. 8.2.1.0 Introduced. Before enabling this feature, enable the enable bgp four-octet-as-supportcommand. If you disable the four-octect-support command after using dot or dot+ format, the AS numbers revert to asplain text. When you apply an asnotation, it is reflected in the running-configuration. If you change the notation type, the running-config updates dynamically and the new notation shows.
Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. If you enable this command, use the clear ip bgp * command to recompute the best path. bgp bestpath as-path multipath-relax Include prefixes received from different AS paths during multipath calculation.
To disable MED comparison on BGP confederation paths, enter the no bgp bestpath med confed command. Defaults Disabled Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.
Usage Information Version Description 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. 6.3.1.0 Introduced The MED is a 4-byte unsigned integer value and the default behavior is to assume a missing MED as 4294967295. This command causes a missing MED to be treated as 0. During path selection, paths with a lower MED are preferred over paths with a higher MED. bgp bestpath router-id ignore Do not compare router-id information for external paths during best path selection.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.
Usage Information Version Description 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. When a BGP cluster contains only one route reflector, the cluster ID is the route reflector’s router ID. For redundancy, a BGP cluster may contain two or more route reflectors. Assign a cluster ID with the bgp cluster-id command. Without a cluster ID, the route reflector cannot recognize route updates from the other route reflectors within the cluster.
Usage Information Version Description 7.7.1.0 Introduced on the C-Series. Added support for the 4-byte format To accept 4-byte formats before entering a 4-byte AS number, configure your system. All the routers in the Confederation must be 4 byte or 2 byte identified routers. You cannot mix them. The autonomous systems configured in this command are visible to the EBGP neighbors. Each autonomous system is fully meshed and contains a few connections to other autonomous systems.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. Added support for the 4-byte format. All the routers in the Confederation must be 4 byte or 2 byte identified routers. You cannot mix them. The autonomous systems configured in this command are visible to the EBGP neighbors.
route-map mapname (OPTIONAL) Enter the keyword route-map then the name of a configured route map. Only match commands in the configured route map are supported. Defaults Command Modes Command History Disabled. • ROUTER BGP • ROUTER BGP-address-family This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.
This command must be performed on the router which is attaching link bandwidth to prefixes (typically a border router) as well as the router which is expected to load share traffic proportional to the bandwidth of the external links. bgp enforce-first-as Disable (or enable) enforce-first-as check for updates received from EBGP peers. S6000 Syntax bgp enforce-first-as To turn off the default, use the no bgp enforce-first-as command.
bgp fast-external-fallover Enable the fast external fallover feature, which immediately resets the BGP session if a link to a directly connected external peer fails. S6000 Syntax bgp fast-external-fallover To disable fast external fallover, use the no bgp fast-external-fallover command. Defaults Enabled Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. Routers supporting 4-byte ASNs advertise that function in the OPEN message. The behavior of a 4-byte router is slightly different depending on whether it is speaking to a 2-byte router or a 4-byte router.
Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. This feature is advertised to BGP neighbors through a capability advertisement. In Receiver Only mode, BGP saves the advertised routes of peers that support this capability when they restart.
Deterministic mode (no bgp non-deterministic-med), Dell Networking OS compares MED between adjacent paths within an AS group because all paths in the AS group are from the same AS. When you change the path selection from Deterministic to Non-Deterministic, the path selection for the existing paths remains Deterministic until you enter the clear ip bgp command to clear existing paths. bgp recursive-bgp-next-hop Enable next-hop resolution through other routes learned by BGP.
To re-enable optimization engine, use the no bgp regex-eval-optz-disable command. Defaults Enabled Command Modes ROUTER BGP (conf-router_bgp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000.
bgp router-id Assign a user-given ID to a BGP router. S6000 Syntax bgp router-id ip-address To delete a user-assigned IP address, use the no bgp router-id command. Parameters ip-address Enter an IP address in dotted decimal format to reset only that BGP neighbor. Defaults The router ID is the highest IP address of the Loopback interface or, if no Loopback interfaces are configured, the highest IP address of a physical interface on the router.
NOTE: Use this attribute to clear a BGP instance corresponding to either a specific address family in a default VRF or an IPv4 address family in a a non-default VRF. * Enter an asterisk ( * ) to reset all BGP sessions. <1-4294967295> Enter <1-4294967295> to clear peers with the AS number. <0.1-65535.65535> Enter <0.1-65535.65535> to clear peers with the AS number in dot format. A.B.C.D Enter the BGP neighbor address in the A.B.C.D format to clear.
Related Commands Version Description 6.5.1.0 Expanded to include the as-number option. bgp recursive-bgp-next-hop — disables next-hop resolution through other routes learned by the BGP. clear ip bgp dampening Clear information on route dampening and return the suppressed route to the Active state.
Usage Information Version Description 7.7.1.0 Introduced on the C-Series. After you enter this command, the software deletes the history routes and returns the suppressed routes to the Active state. The clear ip bgp dampening command does not clear the history paths. clear ip bgp flap-statistics Clear BGP flap statistics, which includes number of flaps and the time of the last flap.
• ^ = (caret) the beginning of the input string. If you use the caret at the beginning of a sequence or range, it matches on everything BUT the characters specified. • $ = (dollar sign) the end of the output string. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
ipv4 unicast (OPTIONAL) Enter the keyword ipv4 followed by the keyword unicast to reset ipv4 unicast routes. ipv6 unicast (OPTIONAL) Enter the keyword ipv6 followed by the keyword unicast to reset ipv6 unicast routes. soft (OPTIONAL) Enter the keyword soft to reset soft configuration. in Enter the keyword in to re-configure soft inbound updates. out Enter the keyword out to re-configure soft outbound updates. Command Modes EXEC Privilege Command History This guide is platform-specific.
out (OPTIONAL) Enter the keyword out to view only information on outbound BGP routes. A.B.C.D Enter the IP address of peer in the A.B.C.D format. X:X:X:X::X Enter the IPv6 IP address of peer in the X:X:X:X::X format. dampening Enter the keyword dampening to view BGP dampening. events Enter the keyword events to view BGP protocol events. ipv4 Enter the ipv4 IP address to view the IPV4 route information. ipv6 Enter the ipv6 IP address to view the IPV6 route information.
debug ip bgp updates — views information about BGP updates. show debugging — views enabled debugging operations. debug ip bgp dampening View information on routes being dampened. S6000 Syntax debug ip bgp [vrf vrf-name] [ipv4 {unicast | multicast} | ipv6 unicast] dampening To disable debugging, use the no debug ip bgp dampening command. Parameters vrf vrf-name Enter the keyword vrf followed by the name of the VRF to view information on dampened routes corresponding to that VRF.
debug ip bgp events Display information on local BGP state changes and other BGP events. S6000 Syntax debug ip bgp [vrf vrf-name] [A.B.C.D | X:X:X:X::X | peer-group peer-groupname] events [in | out] To disable debugging, use the no debug ip bgp [vrf vrf-name] [A.B.C.D | X:X:X:X::X | peer-group peer-group-name] events [in | out] command. Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to display BGP state changes corresponding to that VRF. A.B.C.
debug ip bgp keepalives Display information about BGP keepalive messages. S6000 Syntax debug ip bgp [vrf vrf-name] [A.B.C.D | X:X:X:X::X | peer-group peer-groupname] keepalives [in | out] To disable debugging, use the no debug ip bgp [vrf vrf-name] [A.B.C.D | X:X:X:X::X | peer-group peer-group-name] keepalives [in | out] command. Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to display BGP keepalive information corresponding to that VRF. A.B.C.
To disable debugging, use the no debug ip bgp [vrf vrf-name] [A.B.C.D | X:X:X:X::X | peer-group peer-group-name] notifications [in | out] command. Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to view neighbor BGP notification information corresponding to that VRF. A.B.C.D (OPTIONAL) Enter the IPv4 address of the neighbor. X:X:X:X::X (OPTIONAL) Enter an IPv6 address.
X:X:X:X::X (OPTIONAL) Enter an IPv6 address. peer-group-name (OPTIONAL) Enter the name of the peer group to disable or enable all routers within the peer group.. Defaults Disabled Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
out (OPTIONAL) Enter the keyword out to view only BGP updates sent to neighbors. prefix-list prefix-listname (OPTIONAL) Enter the keyword prefix-list then the name of an established prefix list. If the prefix list is not configured, the default is permit (to allow all routes). ip-address (OPTIONAL) Enter the IP address of the neighbor in dotted decimal format. peer-group-name (OPTIONAL) Enter the name of the peer group to disable or enable all routers within the peer group.
Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. Usage Information The default-metric command in BGP sets the value of the BGP MULTI_EXIT_DISC (MED) attribute for redistributed routes only. Related Commands bgp always-compare-med — enables comparison of all BGP MED attributes.
Defaults none Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.8.0 Support from 2 to 64 paths on the S4810. Command syntax changed to maxpath (was maximum-paths). 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. If you enable this command, use the clear ip bgp * command to recompute the best path.
It is not possible to de-activate a peer from the IPv4 unicast address family. neighbor add-path This command allows the specified neighbor/peer group to send/receive multiple path advertisements. S6000 Syntax Parameters neighbor [ip-address | peer-group-name] add-path [send | receive | both] path-count ip-address (OPTIONAL) Enter the IP address of the neighbor in dotted decimal format. peer-group-name (OPTIONAL) Enter the name of the peer group.
Parameters Defaults ip-address (OPTIONAL) Enter the IP address of the neighbor in dotted decimal format. peer-group-name Enter the name of the peer group to set the advertisement interval for all routers in the peer group. seconds Enter a number as the time interval, in seconds, between BGP advertisements. The range is from 0 to 600 seconds. The default is 5 seconds for internal BGP peers and 30 seconds for external BGP peers.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. neighbor allowas-in Set the number of times an AS number can occur in the AS path.
Usage Information You cannot set this configuration for a peer that is associated with a peer group. Similarly, you cannot associate a peer to a peer group if that peer is already configured with these settings. Related Commands bgp four-octet-as-support — enables 4-byte support for the BGP process. neighbor default-originate Inject the default route to a BGP peer or neighbor.
When you apply a default route to a BGP peer or peer group using the neighbor default-originate command, changes to the configured default route-map are applied to the BGP peer or peer group only after a delay of 15 seconds. As a result, you must wait for a period of 15 seconds before manually resetting BGP using the clear ip bgp command. In case of eBGP, the neighbor default-originate command does not support extendedcommunity as a non-transtive route-map attribute.
neighbor distribute-list Distribute BGP information via an established prefix list. S6000 Syntax neighbor {ip-address | peer-group-name} distribute-list prefix-list-name {in | out} To delete a neighbor distribution list, use the no neighbor {ip-address | peer-group-name} distribute-list prefix-list-name {in | out} command. Parameters ip-address Enter the IP address of the neighbor in dotted decimal format.
neighbor ebgp-multihop Attempt and accept BGP connections to external peers on networks that are not directly connected. S6000 Syntax neighbor {ip-address | peer-group-name} ebgp-multihop [ttl] To disallow and disconnect connections, use the no neighbor {ip-address | peer-groupname} ebgp-multihop command. Parameters ip-address Enter the IP address of the neighbor in dotted decimal format. peer-group-name Enter the name of the peer group.
Defaults Disabled. Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series.
Defaults threshold = 75 Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series.
Parameters ip-address Enter the IP address of the router to be included in the peer group. peer-group-name Enter the name of a configured peer group. dmzlink-bw Enter the keyword dmzlink-bw to attach a link bandwidth to received routes. NOTE: If dmzlink-bw is configured for a peer, in order for the BGP peer to advertise the prefixes with dmzlink-bw attached to it, you must reset the the peer or peer-group using the clear ip bgp session command. Defaults Not configured.
neighbor peer-group (creating group) — creates a peer group. show ip bgp peer-group — views BGP peers. show ip bgp neighbors — views BGP neighbors configurations. neighbor peer-group (creating group) Allows you to create a peer group and assign it a name. S6000 Syntax neighbor peer-group-name peer-group To delete a peer group, use the no neighbor peer-group-name peer-group command. Parameters peer-group-name Enter a text string up to 16 characters long as the name of the peer group.
To delete a passive peer-group, use the no neighbor peer-group-name peer-group passive command. Parameters peer-group-name Enter a text string up to 16 characters long as the name of the peer group. Defaults Not configured. Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
number Enter a number of the AS. The range is from 0 to 65535 (2 byte) or from 1 to 4294967295 (4 byte). Defaults Not configured. Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 8.3.19.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series.
Defaults Not configured. Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. A route reflector reflects routes to the neighbors assigned to the cluster. Neighbors in the cluster do not need not to be fully meshed.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version 9.0.2.0 Introduced on the S6000. Version 8.3.11.1 Introduced on the Z9000. Version 7.8.1.0 Introduced on the S-Series. Version 7.7.1.0 Introduced on the C-Series.
Usage Information Peers that are enabled within a peer group are disabled when their peer group is disabled. The neighbor shutdown command terminates all BGP sessions on the BGP neighbor or BGP peer group. Use this command with caution as it terminates the specified BGP sessions. When a neighbor or peer group is shut down, use the show ip bgp summary command to confirm its status. Related Commands show ip bgp summary — displays the current BGP configuration.
CAUTION: Inbound update storage is a memory-intensive operation. The entire BGP update database from the neighbor is stored in memory regardless of the inbound policy results applied on the neighbor. NOTE: This command is supported in BGP Router Configuration mode for IPv4 Unicast address only. Related Commands show ip bgp neighbors — displays routes received by a neighbor. neighbor timers Set keepalive and hold time timers for a BGP neighbor or a peer group.
Usage Information Timer values configured with the neighbor timers command override the timer values configured with any other command. When two neighbors, configured with different keepalive and holdtime values, negotiate for new values, the resulting values are as follows: • the lower of the holdtime value is the new holdtime value, and • whichever is the lower value; one-third of the new holdtime value, or the configured keepalive value, is the new keepalive value.
neighbor weight Assign a weight to the neighbor connection, which is used to determine the best path. S6000 Syntax neighbor {ip-address | peer-group-name} weight weight To remove a weight value, use the no neighbor {ip-address | peer-group-name} weight command. Parameters ip-address Enter the IP address of the peer router in dotted decimal format. peer-group-name Enter the name of the peer group to disable all routers within the peer group. weight Enter a number as the weight.
To remove a network, use the no network ip-address mask [route-map map-name] command. Parameters ip-address Enter an IP address in dotted decimal format of the network. mask Enter the mask of the IP address in the slash prefix length format (for example, / 24). The mask appears in command outputs in dotted decimal format (A.B.C.D). route-map mapname (OPTIONAL) Enter the keyword route-map then the name of an established route map.
When a combination of locally originated and peer originated routes occurs, both these routes will exist in the RTM. However, only the best route is kept active in the RTM and the remaining route is rendered inactive. It is possible to keep only one locally originated route in the BGP database. Network command has preference over the re-distributed routes. When the locally originated route is no longer present in the database the other route is automatically installed.
permit bandwidth Enables you to specify link band width extended-community attribute as the matching criteria to permit incoming or outgoing traffic. Syntax permit bandwidth To disable this setting, enter the no permit bandwidth command. Parameters bandwidth Enter the keyword bandwidth to specify extended-community attribute as the matching criteria for permitting traffic. The range is from 0 to 102400.
Defaults Not configured. Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Parameters process-id Enter the number of the OSPF process. The range is from 1 to 65535. match external {1 | 2} (OPTIONAL) Enter the keywords match external to redistribute OSPF external routes. You can specify 1 or 2 to redistribute those routes only. match internal (OPTIONAL) Enter the keywords match internal to redistribute OSPF internal routes only. route-map mapname (OPTIONAL) Enter the keywords route-map then the name of a configured route map. Defaults Not configured.
Parameters as-number Enter the AS number. The range is from 1 to 65535 (2 byte), from 1 to 4294967295 (4 byte), or from 0.1 to 65535.65535 (dotted format). Defaults Not enabled. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.
Usage Information A new policy command is introduced in order to attach the Link Bandwidth extended community only to the prefixes that are received from a neighbor that satisfy the desired conditions. This command is relevant for both inbound as well as outbound policy handling (for received prefixes). Also, there is no change to the set of supported conditions or filters. During configuration, the bandwidth is specified in Mbps, not in bytes/second.
Outgoing packet capture enabled for BGP neighbor 20.20.20.2 Available buffer size 40958758, 27 packet(s) captured using 562 bytes PDU[1] : len 41, captured 00:34:52 ago ffffffff ffffffff ffffffff ffffffff 00290104 000100b4 14141401 0c020a01 04000100 01020080 00000000 PDU[2] : len 19, captured 00:34:51 ago ffffffff ffffffff ffffffff ffffffff 00130400 PDU[3] : len 19, captured 00:34:50 ago ffffffff ffffffff ffffffff ffffffff 00130400 [. . .] Dell# show config View the current ROUTER BGP configuration.
Parameters Command Modes Command History vrf vrf-name (OPTIONAL) Enter the keyword vrf and then the name of the VRF to view ipv4– unicast route information corresponding to that VRF. ipv4 unicast (OPTIONAL) Enter the keywords ipv4 unicast to view information only related to ipv4 unicast routes. network (OPTIONAL) Enter the network address (in dotted decimal format) of the BGP network to view information only on that network.
Field Description Weight Displays the route’s weight. Path Lists all the ASs the route passed through to reach the destination network. The show ip bgp command displays the dmzlink-dw details only if dmzlink-bw is enabled using the bgp dmzlink-dw command. Example Dell#show ip bgp BGP local RIB : Routes to be Added 0, Replaced 0, Withdrawn 0 BGP local router ID is 192.168.11.
Command Modes Command History ipv6 unicast (OPTIONAL) Enter the keyword ipv6 followed by the keyword unicast to view information related to only to the ipv6 unicast routes. cluster-id (OPTIONAL) Enter the cluster id in dotted decimal format. The range is 1 — 4294967295. • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Dell#show ip bgp cluster-list 4.4.4.4 BGP local RIB : Routes to be Added 0, Replaced 0, Withdrawn 0 BGP local router ID is 192.168.11.6 Status codes: s suppressed, S stale, d dampened, h history, * valid, > best Path source: I - internal, a - aggregate, c - confed-external, r redistributed n - network, D - denied, S - stale Origin codes: i - IGP, e - EGP, ? - incomplete Network *>I 55.0.0.0/24 500 600 i *>I 66.0.0.0/24 *>I 77.0.0.0/24 Dell# Next Hop 172.16.0.2 Metric 172.16.0.2 172.16.0.
no-export Enter the keywords no-export to view all routes containing the well-known community attribute of NO_EXPORT. All routes with the NO_EXPORT (0xFFFFFF01) community attribute must not be advertised outside a BGP confederation boundary. Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
aa:nn | Community number in aa:nn format Pipe through a command Dell#show ip bgp community BGP local RIB : Routes to be Added 0, Replaced 0, Withdrawn 0 BGP local router ID is 192.168.11.5 Status codes: s suppressed, S stale, d dampened, h history, * valid, > best Path source: I - internal, a - aggregate, c - confed-external, r redistributed n - network, D - denied, S - stale Origin codes: i - IGP, e - EGP, ? - incomplete *> *> Network 55.0.0.0/24 66.0.0.0/24 Next Hop 172.16.0.2 172.16.0.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Added ipv4 multicast and ipv6 unicast parameters. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series.
Origin IGP, Metric external 4294967295 (Default), LocalPref Communities : 200:1 1000:1 100, Weight 0, 3000:1 show ip bgp dampened-paths View BGP routes that are dampened (non-active). S6000 Syntax Parameters Command Modes Command History show ip bgp [vrf vrf-name] [ipv4 {multicast | unicast} | ipv6 unicast] dampened-paths vrf vrf-name (OPTIONAL) Enter the keywords vrf and then the name of the VRF to view routes that are affected by a specific community list corresponding to that VRF.
The history paths that the show ip bgp command displays contain only the prefix and the next-hop information. The next-hop information shows the ip address of the neighbor. It does not show the actual next-hop details. The following describes the show ip bgp damp command shown in the following example. Example Field Description Network Displays the network ID to which the route is dampened. From Displays the IP address of the neighbor advertising the dampened route.
Example Version Description 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. 7.5.1.0 Introduced.
NdAFWPtrP 0 NdAFWLen 0 : NdAfNH : NdAFRedRttP 0x41a0d400 : NdRecCtxAdd 1101110868 NdRedCtxAddrLen 255 : NdAfRedMkrP 0x41a19e88 : AFAggRttP 0x41a0d600 : AfAggCtxAddr 1101111028 : AfAggrCtxAddrLen 255 AfNumAggrPfx 0 : AfNumAggrASSet 0 : AfNumSuppmap 0 : AfNumAggrValidPfx 0 : AfMPathRttP 0x41a0d700 MpathCtxAddr 1101111140 : MpathCtxAddrlen 255 : AfEorSet 0x41a19f98 : NumDfrdPfx 0 AfActPeerHd 0x41a1a3a4 : AfExtDist 1101112312 : AfIntDist 200 : AfLocDist 200 AfNumRRc 0 : AfRR 0 : AfNetRttP 0x41a0d300 : AfNetCtxA
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. To view the total number of COMMUNITY attributes found, use the show ip bgp summary command. The text line above the route table states the number of COMMUNITY attributes found.
Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Example Version Description 9.7(0.0) Added the ipv4 multicast and ipv6 unicast parameters. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.
Path source: I - internal, a - aggregate, c - confed-external, r redistributed n - network, D - denied, S - stale Origin codes: i - IGP, e - EGP, ? - incomplete *> 400 *> 500 Network 55.0.0.0/24 500 600 i 66.0.0.0/24 i Next Hop 172.16.0.2 Metric LocPrf Weight Path 0 200 172.16.0.2 0 200 show ip bgp flap-statistics View flap statistics on BGP routes.
• Command Modes Command History • EXEC • EXEC Privilege $ = (dollar sign) the end of the output string. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Example Version Description 9.7(0.0) Added the ipv4 multicast and ipv6 unicast parameters. 9.4.(0.0) Added support for VRF. 9.0.2.
00:00:00 200 i Dell#*>n 66.66.77.77/32 0.0.0.0 0 32768 i show ip bgp inconsistent-as View routes with inconsistent originating autonomous system (AS) numbers; that is, prefixes that are announced from the same neighbor AS but with a different AS-Path.
Example Field Description Path Lists all the ASs the route passed through to reach the destination network. Dell>show ip bgp inconsistent-as BGP table version is 280852, local router ID is 10.1.2.100 Status codes: s suppressed, d damped, h history, * valid, > best Path source: I - internal, c - confed-external, r - redistributed, n network Origin codes: i - IGP, e - EGP, ? - incomplete Network Next * 3.0.0.0/8 * * *> *> 3.18.135.0/24 * * * *> 4.0.0.0/8 * * * * 6.0.0.0/20 * *> * * 9.2.0.
statistics | routes | {received-routes [network [network-mask]]} | {deniedroutes [network [network-mask]]}] Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf and then the name of the VRF to view information exchanged by BGP neighbors corresponding to that VRF. NOTE: You can use this attribute to view information exchanged by BGP neighbors that correspond to either a default or a non-default VRF.
Usage Information Version Description 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.8.0 Added the add-path option to the S4810. Output on the S4810 shows the ADDPATH parameters. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. 7.5.1.0 Added the detail option. Output now displays the default MED value. 7.2.1.
Example The Lines Beginning with: Description Sent messages The line displays the number of BGP messages sent, the number of notifications (error messages), and the number of messages waiting in a queue for processing. Received updates This line displays the number of BGP updates received and sent. Soft reconfiguration This line indicates that soft reconfiguration inbound is configured. Minimum time Displays the minimum time, in seconds, between advertisements.
For address family: IPv4 Unicast BGP local RIB : Routes to be Added 0, Replaced 0, Withdrawn 0 InQ : Added 0, Replaced 0, Withdrawn 0 OutQ : Added 0, Withdrawn 0 Allow local AS number 0 times in AS-PATH attribute Prefixes accepted 2, withdrawn 15 by peer, martian prefixes ignored 0 Prefixes advertised 0, denied 0, withdrawn 0 from peer Connections established 1; dropped 0 Last reset never Local host: 172.16.0.1, Local port: 58145 Foreign host: 172.16.0.
Example Field Description Next-hop Displays the next-hop IP address. Via Displays the IP address and interface used to reach the next hop. RefCount Displays the number of BGP routes using this next hop. Cost Displays the cost associated with using this next hop. Flaps Displays the number of times the next hop has flapped. Time Elapsed Displays the time elapsed since the next hop was learned. If the route is down, this field displays time elapsed since the route went down.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Added support for VRF for the S4810, S4820T, and S6000. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf to view all unique COMMUNITY numbers in the BGP database corresponding to that VRF. NOTE: You can use this attribute to view information on unique COMMUNITY numbers in a BGP database that correspond to either a default or a non-default VRF. Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
show ip bgp peer-group Allows you to view information on the BGP peers in a peer group. S6000 Syntax show ip bgp [vrf vrf-name] [ipv4 {multicast | unicast} | ipv6 unicast] peer-group [peer-group-name [detail | summary]] Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf to view information on BGP peers in a peer group corresponding to that VRF. NOTE: You can use this attribute to view information on BGP peers in a peer group that correspond to either a default or a non-default VRF.
Usage Information Example Version Description 7.7.1.0 Introduced on the C-Series. The following describes the show ip bgp peer-group command shown in the following example. Line beginning with: Description Peer-group Displays the peer group’s name. Administratively shut Displays the peer group’s status if the peer group is not enabled. If you enable the peer group, this line is not displayed. BGP version Displays the BGP version supported.
NOTE: You can use this attribute to view the subset of BGP routing tables that match the regular expression that is specified on either a default or a non-default VRF. regular-expression [character] Enter a regular expression then use one or a combination of the following characters to match: • . = (period) any single character (including a white space). • * = (asterisk) the sequences in a pattern (zero or more sequences). • + = (plus) the sequences in a pattern (one or more sequences).
Example Field Description Metric Displays the BGP router’s metric, if assigned. LocPrf Displays the BGP LOCAL_PREF attribute for the route. Weight Displays the route’s weight Path Lists all the AS paths the route passed through to reach the destination network. Dell#show ip bgp regexp ^200 BGP local RIB : Routes to be Added 0, Replaced 0, Withdrawn 0 BGP local router ID is 192.168.11.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. In BGP, route attributes are maintained at different locations. When attributes that correspond to multiple routes change, then attribute counts that the show ip bgp summary command displays are calculated as summations of attributes corresponding to all the associated routes.
Field Description TblVer Displays the version of the BGP table that was sent to that neighbor. InQ Displays the number of messages from that neighbor waiting to be processed. OutQ Displays the number of messages waiting to be sent to that neighbor. If a number appears in parentheses, the number represents the number of messages waiting to be sent to the peer group. Up/Down Displays the amount of time that the neighbor is in the Established stage.
show running-config bgp To display the current BGP configuration, use this feature. S6000 Syntax show running-config bgp Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.
holdtime Enter a number for the time interval, in seconds, between the last keepalive message and declaring the router dead. The range is from 3 to 65535. The default is 180 seconds. Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.
Parameters vrf vrf-name Enter the keyword vrf followed by the name of the VRF to view information on dampened routes corresponding to that VRF. ipv4 multicast (OPTIONAL) Enter the keyword ipv4 followed by the keyword multicast to view dampened-route information related only to ipv4 multicast routes. ipv4 unicast (OPTIONAL) Enter the keyword ipv4 followed by the keyword multicast to view dampened-route information related only to ipv4 unicast routes.
• internal-distance = 200 • local-distance = 200 Command Modes ROUTER BGP (conf-router_bgp_af) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.11.1 Introduced on the Z9000. 7.8.1.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Added the ipv4 multicast and ipv6 unicast parameters. 9.4(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
10 Content Addressable Memory (CAM) Content addressable memory (CAM) commands are supported on the Dell Networking S6000 platform. NOTE: Not all CAM commands are supported on all platforms. Be sure to note the platform when looking for a command. WARNING: If you are using these features for the first time, contact Dell Networking Technical Assistance Center (TAC) for guidance. CAM Profile Commands The CAM profiling feature allows you to partition the CAM to best suit your application.
number] ecfmacl number [nlbclusteracl number] ipv4pbr number }openflow number | fcoe number} [iscsioptacl number] [vrfv4acl number] Parameters 406 default Use the default CAM profile settings and set the CAM as follows: • L2Acl : 6 • IPV4Acl : 4 • IPV6Acl : 0 • IPV4Qos : 2 • L2Qos : 1 • L2PT : 0 • IpMacAcl : 0 • VmanQos : 0 • VmanDualQos : 0 • EcfmAcl : 0 • nlbclusteracl: 0 • FcoeAcl : 0 • iscsiOptAcl : 0 • ipv4pbr : 0 • vrfv4Acl :0 • Openflow : 0 • fedgovacl : 0 l2acl n
NOTE: When you reconfigure CAM allocation, use the nlbclusteracl number command to change the number of NLB ARP entries. The range is from 0 to 2. The default value is 0. At the default value of 0, eight NLB ARP entries are available for use. This platform supports up to 512 CAM entries. Select 1 to configure 256 entries. Select 2 to configure 512 entries.
Usage Information Version Description 9.4.(0.0) Added support for PBR and VRF. 9.2(0.2) Added support for fcoe. 9.1.(0.0) Added support for OpenFlow. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.10.2 Clarified block information for the S4810. 8.3.10.0 Introduced on the S4810. 8.3.1.0 Added the keywords ecfmacl, vman-qos, and vman-dual-qos. 8.2.1.0 Introduced on the S-Series. 7.8.1.0 Introduced on the C-Series.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. cam-optimization Optimize CAM utilization for QoS Entries by minimizing require policy-map CAM space. S6000 Syntax Parameters cam-optimization [qos] qos Optimize CAM usage for QoS. Defaults Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific.
Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.
-- stack-unit 1 -Current Settings(in block sizes) 1 block = 128 entries L2Acl : 6 Ipv4Acl : 4 Ipv6Acl : 0 Ipv4Qos : 2 L2Qos : 1 L2PT : 0 IpMacAcl : 0 VmanQos : 0 VmanDualQos : 0 EcfmAcl : 0 FcoeAcl : 0 iscsiOptAcl : 0 ipv4pbr : 0 vrfv4Acl : 0 Openflow : 0 fedgovacl : 0 nlbclusteracl: 0 test cam-usage Verify that enough CAM space is available for the IPv6 ACLs you have created.
The following describes the test cam-usage command shown in the following example. Term Explanation Stack-Unit Lists the stack unit or units that are checked. Entering all shows the status for all stacks. Portpipe Lists the portpipe (port-set) or port pipes (port-sets) that are checked. Entering all shows the status for linecards or stack units and port-pipes in the chassis. The port set value is from 0 to 0. CAM Partition Shows the CAM profile of the CAM.
Unified Forwarding Table Modes Unified Forwarding Table (UFT) consolidates the resources of several search tables (Layer 2, Layer 3 Hosts, and Layer 3 Route [Longest Prefix Match — LPM]) into a single flexible resource. Trident 2 supports several UFT modes to extract the forwarding tables, as required. By default, Dell Networking OS initializes the table sizes to UFT mode 2 profile, since it provides a reasonable shared memory for all the tables.
Example Version Description 9.7(0.0) Introduced on the S6000, S6000-ON, and Z9500 switch. Dell#show hardware forwarding-table mode Mode L2 MAC Entries L3 Host Entries L3 Route Entries : : : : Current Settings Default 160K 144K 16K Next Boot Settings scaled-l3-hosts 96K 208K 16K Dell# Related Commands 414 hardware forwarding-table mode — selects the mode to initialize the maximum scalability size for L2 MAC table or L3 Host table or L3 Route table.
11 Control Plane Policing (CoPP) The CoPP commands are supported on the Dell Networking S6000 platform. control-plane-cpuqos To manage control-plane traffic, enter control-plane mode and configure the switch. S6000 Syntax control-plane-cpuqos Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.8.0 Introduced on the S4810.
Usage Information Version Description 8.3.8.0 Introduced on the S4810. This command applies the service-policy based on the type of protocol defined in the ACL rules. Create ACL and QoS policies prior to enabling this command. For CoPP, use the keyword cpu-qos when creating qos-policy-input. Related Commands ip access-list extended — creates an extended IP ACL. mac access-list extended — creates an extended MAC ACL. qos-policy-input — creates a QoS input policy map.
-------------Q0 Q1 Q2 Q3 Q4 Q5 Q6 Q7 Q8 Q9 Q10 Q11 ----------1300 300 300 400 2000 300 400 400 400 600 300 300 ----------512 50 50 50 50 50 50 50 50 50 50 50 show ip protocol-queue-mapping Display the queue mapping for each configured protocol. S6000 Syntax show ip protocol-queue-mapping Defaults Not configured. Command Modes EXEC Privilege Command History This guide is platform-specific.
Dell# Dell# Dell# show ipv6 protocol-queue-mapping Display the queue mapping for each configured IPv6 protocol. S6000 Syntax show ipv6 protocol-queue-mapping Defaults Not configured. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.
Defaults Not configured. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.8.
12 Data Center Bridging (DCB) Data center bridging (DCB) refers to a set of IEEE Ethernet enhancements that provide data centers with a single, robust, converged network to support multiple traffic types, including local area network (LAN), server, and storage traffic. The Dell Networking operating software commands for data center bridging features include 802.1Qbb priority-based flow control (PFC), 802.1Qaz enhanced transmission selection (ETS), and the data center bridging exchange (DCBX) protocol.
Usage Information Version Description 8.3.12.0 Introduced on the S4810. 8.3.16.0 Introduced on the MXL 10/40GbE Switch IO Module. By default, iSCSI is enabled on the unit and the flow control is enabled on all of the interfaces. It is also acts as defaults when the link-level flow control is enabled on one or more interfaces. Enables priority flow control or enhance transmission selection on interface.
pfc no-drop queues Configure the port queues that still function as no-drop queues for lossless traffic. Syntax pfc no-drop queues queue-range To remove the no-drop port queues, use the no pfc no-drop queues command. Parameters queue-range Enter the queue range. Separate the queue values with a comma; specify a priority range with a dash; for example, pfc no-drop queues 1,3 or pfc no-drop queues 7 or pfc no-drop queues 0,7. The range is from 0 to 3. Defaults No lossless queues are configured.
show dcb Displays the data center bridging status, the number of PFC-enabled ports, and the number of PFC-enabled queues. Syntax show dcb [stack-unit unit-number] [port-set port-set-number] Parameters unit-number Enter the DCB unit number. port-set-number Enter the port-set number. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.16.0 Introduced on the MXL 10/40GbE Switch IO Module. To clear the PFC TLV counters, use the clear pfc counters interface port-type slot/ port[] command. The following describes the show interface pfc summary command shown in the following example. Field Description Interface Interface type with stack-unit and port number.
Field Description Application Priority TLV: Local ISCSI Priority Map Priority bitmap the local DCBX port uses in ISCSI advertisements in application priority TLVs. Application Priority TLV: Remote FCOE Priority Map Status of FCoE advertisements in application priority TLVs from the remote peer port: enabled or disabled. Application Priority TLV: Remote ISCSI Priority Map Status of iSCSI advertisements in application priority TLVs from the remote peer port: enabled or disabled.
ISCSI TLV Tx Status is disabled Local FCOE PriorityMap is 0x8 Local ISCSI PriorityMap is 0x10 Remote FCOE PriorityMap is 0x8 Remote ISCSI PriorityMap is 0x8 0 Input TLV pkts, 1 Output TLV pkts, 0 Error pkts, 0 Pause Tx pkts, 0 Pause Rx pkts show interface pfc statistics Displays counters for the PFC frames received and transmitted (by dot1p priority class) on an interface. Syntax Parameters show interface port-type slot/port[] pfc statistics port-type Enter the port type.
dcb-enable Enable data center bridging. Syntax dcb enable[pfc-queues 1|4] To disable DCB, use the no dcb enable command. Parameters pfc-queues Enter the pfc-queue range. To disable DCB, use the no dcb enable command. The range is from 1 or 2. Defaults None Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.16.0 Introduced on the MXL 10/40GbE Switch IO Module. show interface ets Displays the ETS configuration applied to egress traffic on an interface, including priority groups with priorities and bandwidth allocation.
5 6 7 - - Remote Parameters : ------------------Remote is disabled Local Parameters : -----------------Local is enabled TC-grp Priority# Bandwidth TSA -----------------------------------------------0 1 0,1,2 100% ETS 2 3 0 % SP 3 4,5,6,7 0 % SP 4 5 6 7 Oper status is init ETS DCBX Oper status is Down State Machine Type is Asymmetric Conf TLV Tx Status is enabled Reco TLV Tx Status is enabled 0 Input Conf TLV Pkts, 1955 Output Conf TLV Pkts, 0 Error Conf TLV Pkts 0 Input Reco TLV Pkts, 1955 Output Reco TL
5 6 7 - - Oper status is init ETS DCBX Oper status is Down State Machine Type is Asymmetric Conf TLV Tx Status is enabled Reco TLV Tx Status is enabled 0 Input Conf TLV Pkts, 1955 Output Conf TLV Pkts, 0 Error Conf TLV Pkts 0 Input Reco TLV Pkts, 1955 Output Reco TLV Pkts, 0 Error Reco TLV Pkts Dell# show interfaces tengigabitethernet 1/1 ets detail Interface TenGigabitEthernet 1/1 Max Supported TC Groups is 4 Number of Traffic Classes is 8 Admin mode is on Admin Parameters : -----------------Admin is en
Class Pkts Example (Detail) Dell(conf)# show interfaces tengigabitethernet 1/1 ets detail Interface TenGigabitEthernet 1/1 Max Supported TC Groups is 4 Number of Traffic Classes is 8 Admin mode is on Admin Parameters : -----------------Admin is enabled TC-grp Priority# Bandwidth TSA 0 0,1,2,3,4,5,6,7 100% ETS 1 0% ETS 2 0% ETS 3 0% ETS 4 0% ETS 5 0% ETS 6 0% ETS 7 0% ETS Priority# 0 1 2 3 4 5 6 7 Remote Parameters: ------------------Remote is disabled Local Parameters : -----------------Local is enabled TC
DCBX Commands The following DCBX commands are supported on the Dell Networking OS. advertise dcbx-tlv On a DCBX port with a manual role, configure the PFC and ETS TLVs advertised to DCBX peers. Syntax advertise dcbx-tlv {ets-conf | ets-reco | pfc} [ets-conf | ets-reco | pfc] [ets-conf | ets-reco | pfc] To remove the advertised ETS TLVs, use the no advertise dcbx-tlv command.
To remove DCBX port role, use the no dcbx port-role {config-source | auto-downstream | auto-upstream | manual} command. Parameters config-source | auto-downstream | auto-upstream | manual Enter the DCBX port role, where: • config-source: configures the port to serve as the configuration source on the switch. • auto-upstream: configures the port to receive a peer configuration. The configuration source is elected from auto-upstream ports.
• ieee-v2: configures the port to use IEEE 802.1az (Draft 2.5). Defaults Auto Command Modes INTERFACE PROTOCOL LLDP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.16.0 Introduced on the MXL 10/40GbE Switch IO Module. fcoe priority-bits Configure the FCoE priority advertised for the FCoE protocol in application priority TLVs.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.16.0 Introduced on the MXL 10/40GbE Switch IO Module.
Field Description DCBX Operational Status Operational status (enabled or disabled) used to elect a configuration source and internally propagate a DCB configuration. The DCBX operational status is the combination of PFC and ETS operational status. Configuration Source Specifies whether the port serves as the DCBX configuration source on the switch: true (yes) or false (no). Local DCBX Compatibility mode DCBX version accepted in a DCB configuration as compatible.
Example Field Description Total DCBX Frames unrecognized Number of unrecognizable DCBX frames received.
Defaults None. There are no pre-configured PFC and ETS settings on S5000 Ethernet interfaces. Command Modes CONFIGURATION INTERFACE Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.0) Introduced on the S4810 and S6000 platforms. A DCB map is a template used to configure DCB parameters and apply them on converged Ethernet interfaces. DCB parameters include priority-based flow control (PFC) and enhanced traffic selection (ETS).
Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.0) Introduced on the S4810, S6000 platforms. PFC and ETS settings are not pre-configured on Ethernet ports. You must use the dcb-map command to configure different groups of 802.1p priorities with PFC and ETS settings. Using the priority-pgid command, you assign each 802.1p priority to one priority group. A priority group consists of 802.
Defaults None Command Modes DCB MAP Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.6(0.0) Added support to configure peak and committed rate on the S6000 platform. 9.3(0.0) Introduced on the S4810, S6000 platforms. Use the dcb-map command to configure priority groups with PFC and/or ETS settings and apply them to Ethernet interfaces. Use the priority-pgid command to map 802.1p priorities to a priority group. You can assign each 802.
Command Modes Command History Usage Information CONFIGURATION Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.0) Introduced on the S4810 and S6000 platforms. The dcb-map stack-unit all stack-ports all command overwrites any previous DCB maps applied to stack ports. dcb pfc-shared-buffer-size Configure the maximum amount of shared buffer size for PFC packets in kilobytes. You must configure the shared buffer size to be less than the total PFC buffer size.
dcb-buffer-threshold Configure the profile name for the DCB buffer threshold. This utility is supported on the S4810, S4820T, and S6000 platforms. S6000 Syntax dcb buffer—threshold profile-name Parameters profile-name Enter the name of the profile, which can be a string of up to 32 characters in length. Default None Command Modes CONFIGURATION mode Command History Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.0) Introduced on the S4810, S4820T, and S6000 platforms.
size Weightage of the priorities on the shared buffer size in the system. Enter a number in the range of 0 to 9. The default shared threshold weight is 10. Default The default size of the ingress buffer is 45 KB. The default buffer limit at which the port sends the pause to peer and recommences the sending of packets to the peer is 10 KB. The default threshold weight of the shared buffer space is 10. Command Modes DCB-BUFFER-THRESHOLD mode Command History Usage Information Version Description 9.
no-drop The packets for this queue must not be dropped value Enter a number in the range of 0 to 7 to denote the priority to be allocated to the dynamic buffer control mechanism buffer-size Ingress buffer size size Size of the ingress buffer in KB. Enter a number in the range of 0 to 7787. The default is 45 KB. pause-threshold Buffer limit for pause frames to be sent threshold-value Buffer limit at which the port sends the pause to peer in KB. Enter a number in the range of 0 to 7787.
Dell(conf-qos-policy-buffer)# queue 4 pause no-drop buffer-size 128000 pause-threshold 103360 resume-threshold 83520 dcb-policy buffer-threshold (Interface Configuration) Assign the DCB policy to the DCB buffer threshold profile on interfaces. This setting takes precedence over the global bufferthreshold setting.
Usage Information Example Version Description 9.3(0.0) Introduced on the S6000 platform.
Example Dell(conf)#dcb pfc-total-buffer-size 5000 Dell(conf)#dcb pfc-total-buffer-size 4000 %ERROR: Total pfc buffer size configured cannot accommodate existing buffer requirement in the system. show running-config dcb-buffer-threshold Displays the DCB buffer threshold details in the running configuration. Syntax show running—config buffer-threshold Command Modes EXEC EXEC Privilege Command History Usage Information Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.
5 6 7 - No No No Denotes dynamic buffering is enabled in respective queues On interface in which PFC is not enabled: Dell#show interface tengigabitethernet 1/20 pfc buffer-threshold The following table describes the output fields displayed for the show interface pfc buffer-threshold comm Field Description queue Number of the queue lossless Whether the queue is a lossy or lossless queue for wh threshold is configured buffer-size Ingress buffer size pause-threshold-value Buffer limit at which th
dcb {ets | pfc} enable Enable priority flow control or enhanced transmission selection on interface. Syntax dcb {ets | pfc} enable • To disable ETS on interface, use “no dcb ets enable” command. • To disable PFC on interface, use “no dcb pfc enable” command. Defaults Enable Command Modes INTERFACE Command History Usage Information Limitations Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3 (0.1) Introduced on S6000, S4810, and S4820T.
13 Debugging and Diagnostics The basic debugging and diagnostic commands are supported by the Dell Networking Operating System. This chapter contains the following sections: • Diagnostic and Monitoring Commands • Offline Diagnostic Commands • Hardware Commands Diagnostics and Monitoring Commands The following section describes the diagnostics and monitoring commands. For similar commands, refer to the Control and Monitoring chapter. logging coredump stack-unit Enable coredump on a stack.
Offline Diagnostic Commands The offline diagnostics test suite is useful for isolating faults and debugging hardware. While tests are running, Dell Networking OS results are saved as a text file (TestReport-SU-X.txt) in the flash directory. This show file command is available only on master and standby. Important Points to Remember • Offline diagnostics can only be run when the unit is offline. • You can only run offline diagnostics on a unit to which you are connected via the console.
Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.
The system reboots when the off-line diagnostics complete. This reboot is an automatic process. A warning message appears when the offline stack-unit command is implemented. Warning - Diagnostic execution will cause stack-unit to reboot after completion of diags. Proceed with Offline-Diags [confirm yes/no]:y Related Commands show environment (S-Series) — views the S-Series system component status (for example, temperature, voltage). online stack-unit Place a stack unit in the online state.
Hardware Commands These commands display information from a hardware sub-component or ASIC. clear hardware stack-unit Clear statistics from selected hardware components.
clear hardware system-flow Clear system-flow statistics from selected hardware components. Syntax Parameters clear hardware system-flow layer2 stack-unit number port-set 0–0 counters stack-unit number Enter the keywords stack-unit then a number to select a particular stack member and then enter one of the following command options to clear a specific collection of data. The range is from 0 to 5.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.7(0.0) Introduced this command. hardware watchdog To trigger a reboot and restart the system, set the watchdog timer. Syntax hardware watchdog stack-unit {<0-5> | all} Defaults Enabled. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. The unit numbers given are internal port numbers. show hardware layer3 Display Layer 3 ACL or QoS data for the selected stack member and stack member port-pipe.
statistics | stack-port | ti-monitor | unit 0-1 {counters | details | portstats [detail] | register}} Parameters stack-unit stackunit {commandoption} Enter the keywords stack-unit to select a particular stack member and then enter one of the following command options to display a collection of data based on the option entered. The range is from 0 to 5. buffer Enter the keyword buffer. To display the total buffer statistics for the stack unit, enter the keyword total-buffer.
Example (DataPlane) Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.5 Added i2c statistics and sata-interfaces statistics. 8.3.11.4 Added user port information. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series.
ge6 !ena ge7 !ena ge8 !ena ge9 !ena ge10 !ena ge11 !ena ge12 !ena ge13 !ena ge14 !ena ge15 !ena ge16 !ena ge17 !ena ge18 !ena ge19 !ena ge20 !ena ge21 !ena ge22 !ena ge23 !ena hg0 up 12G FD hg1 up 12G FD hg2 down 10G FD hg3 down 10G FD 0 Dell# Example (Register) 462 SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No No No No Forward Forward Forward Forward Forward Forward Forward Forward Forward Forward Forward For
0x0e709102 BCAST_BLOCK_MASK.ge9 = 0x00000000 0x0e70a102 BCAST_BLOCK_MASK.ge10 = 0x00000000 0x0e70b102 BCAST_BLOCK_MASK.ge11 = 0x00000000 0x0e70c102 BCAST_BLOCK_MASK.ge12 = 0x00000000 0x0e70d102 BCAST_BLOCK_MASK.ge13 = 0x00000000 0x0e70e102 BCAST_BLOCK_MASK.ge14 = 0x00000000 0x0e70f102 BCAST_BLOCK_MASK.ge15 = 0x00000000 0x0e710102 BCAST_BLOCK_MASK.ge16 = 0x00000000 0x0e711102 BCAST_BLOCK_MASK.ge17 = 0x00000000 0x0e712102 BCAST_BLOCK_MASK.ge18 = 0x00000000 0x0e713102 BCAST_BLOCK_MASK.
RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX - MTU Check Error Frame Counter PFC Frame Priority 0 PFC Frame Priority 1 PFC Frame Priority 2 PFC Frame Priority 3 PFC Frame Priority 4 PFC Frame Priority 5 PFC Frame Priority 6 PFC Frame Priority 7 Debug Counter 0 Debug Counter 1 Debug Counter 2 Debug Counter 3 Debug Counter 4 Debug Counter 5 Debug Counter 6 Debug Counte
Description RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX - IPV4 L3 Unicast Frame Counter IPV4 L3 Routed Multicast Packets IPV6 L3 Unicast Frame Counter IPV6 L3 Routed Multicast Packets Unicast Packet Counter 64 Byte Frame Counter 65 to 127 Byte Frame Counter 128 to 255 Byte Frame Counter 256 to 511 Byte Frame Counter 512 to 1023 Byte Frame Counter 1024
TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX Example (Details) - Oversized Frame Counter Jabber Counter VLAN Tag Frame Counter Double VLAN Tag Frame Counter RUNT Frame Counter Fragment Counter PFC Frame Priority 0 PFC Frame Priority 1 PFC Frame Priority 2 PFC Frame Priority 3 PFC Frame Priority 4 PFC Frame Priority 5 PFC Frame Priority 6 PFC Frame Priority 7 Debug Counter 0 Debug Counter 1 Debug Counter 2 Debug Counter 3 Debug Counter 4 Debug Counter 5 Debug Counter 6 Debu
The linkStatus of Front End Port 16 is FALSE The linkStatus of Front End Port 17 is FALSE The linkStatus of Front End Port 18 is FALSE The linkStatus of Front End Port 19 is FALSE The linkStatus of Front End Port 20 is FALSE The linkStatus of Front End Port 21 is FALSE The linkStatus of Front End Port 22 is FALSE The linkStatus of Front End Port 23 is TRUE The linkStatus of Hg Port 24 is TRUE The linkStatus of Hg Port 25 is TRUE The linkStatus of Hg Port 26 is FALSE The linkStatus of Hg Port 27 is FALSE !--
show hardware drops Displays internal drops on the specified interface or for a range of interface. Syntax show hardware drops interface interface Parameters interface drops Command Modes Enter any of the following keywords and slot/port or slot/port-range or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
Packets dropped by FP (L2+L3) Drops Port bitmap zero Drops Rx VLAN Drops --- Ingress MAC counters--Ingress FCSDrops Ingress MTUExceeds --- MMU Drops --Ingress MMU Drops HOL DROPS(TOTAL) HOL DROPS on COS0 HOL DROPS on COS1 HOL DROPS on COS2 HOL DROPS on COS3 HOL DROPS on COS4 HOL DROPS on COS5 HOL DROPS on COS6 HOL DROPS on COS7 HOL DROPS on COS8 HOL DROPS on COS9 HOL DROPS on COS10 HOL DROPS on COS11 HOL DROPS on COS12 HOL DROPS on COS13 HOL DROPS on COS14 HOL DROPS on COS15 HOL DROPS on COS16 HOL DROPS on
Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.8(0.0) Introduced on the S4810, S4820T, S5000, S6000, S6000–ON, Z9500.
show hardware system-flow Display Layer 3 ACL or QoS data for the selected stack member and stack member port-pipe. Syntax Parameters show hardware system-flow layer2 stack-unit id port-set number [counters] acl | qos For the selected stack member and stack member port-pipe, display which system flow entry the packet hits and what queue the packet takes as it dumps the raw system flow tables. stack-unit id Enter the keywords stack-unit to select a stack member ID. The range is from 0 to 5.
384 383 382 380 379 4 3 2 1 25 Dell# Example OSPF[224.0.0.5] Packets 0 OSPF[224.0.0.
show hardware vlan-counters Display the hardware VLAN statistics. Syntax Parameters Defaults Command Modes Command History show hardware vlan-counters vlan-id vlan-id Enter the interface VLAN number. The range is from 1 to 4094. None • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
priority-group Command Modes Enter the keyword priority-group followed by id for specific priority-group or keyword all. EXEC EXEC Privilege Command History Version Description 9.8(0.0) Introduced on the S4810, S4820T, S5000, S6000, S6000–ON, Z9000, Z9500. Usage Information -Queue ucast/mcast — Displays the total unicast/multicast buffer usage on per-port per-queue basis.
UCAST UCAST UCAST UCAST UCAST UCAST Example displaying egress queue-level snapshot for multicast packets for the specific interface 6 7 8 9 10 11 0 0 0 0 0 0 Dell#show hardware buffer-stats-snapshot resource interface fortyGigE 0/0 queue mcast 3 Unit 1 unit: 0 port: 1 (interface Fo 0/0) --------------------------------------Q# TYPE Q# TOTAL BUFFERED CELLS --------------------------------------MCAST 3 0 Dell#show hardware buffer-stats-snapshot resource interface fortyGigE 0/0 queue mcast all Unit 0 unit:
Parameters Command Modes stack-unit stackunit-number Unique ID of the stack unit to select a particular stack member and then enter one of the following command options to display a collection of data based on the option entered. The unit ID range from 0 to 5. buffer-statssnapshot unit number Display the historical snapshot of buffer statistical values unit Enter the keyword unit along with a port-pipe number. The range is from 0 to 0.
MCAST 3 0 Unit 1 unit: 3 port: 9 (interface Fo 1/152) --------------------------------------Q# TYPE Q# TOTAL BUFFERED CELLS --------------------------------------MCAST 3 0 Unit 1 unit: 3 port: 13 (interface Fo 1/156) --------------------------------------Q# TYPE Q# TOTAL BUFFERED CELLS --------------------------------------MCAST 3 0 Unit 1 unit: 3 port: 17 (interface Fo 1/160) --------------------------------------Q# TYPE Q# TOTAL BUFFERED CELLS --------------------------------------MCAST 3 0 Unit 1 unit
14 Dynamic Host Configuration Protocol (DHCP) Dynamic host configuration protocol (DHCP) is an application layer protocol that dynamically assigns IP addresses and other configuration parameters to network end-stations (hosts) based on the configuration policies the network administrators determine. The Dell Networking operating system supports the basic DHCP commands on this platform.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series and S-Series. Entering after the clear ip dhcp binding command clears all the IPs from the binding table. debug ip dhcp server Display FTOS debugging messages for DHCP. S6000 Syntax Parameters debug ip dhcp server [events | packets] events Enter the keyword events to display the DHCP state changes.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S4810, S4820T, S6000 and Z-Series. default-router Assign a default gateway to clients based on the address pool. S6000 Syntax default-router address [address2...address8] Parameters address Enter a list of routers that may be the default gateway for clients on the subnet. You may specify up to eight routers. List them in order of preference.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series and S-Series.
Parameters name Give a name to the group of addresses in a pool. Defaults none Command Modes DHCP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
hardware-address For manual configurations, specify the client hardware address. S6000 Syntax Parameters hardware-address address address Enter the hardware address of the client. Defaults none Command Modes DHCP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series and S-Series. lease Specify a lease time for the addresses in a pool. S6000 Syntax lease {days [hours] [minutes] | infinite} Parameters days Enter the number of days of the lease. The range is from 0 to 31. hours Enter the number of hours of the lease. The range is from 0 to 23. minutes Enter the number of minutes of the lease. The range is from 0 to 59.
Command Modes DHCP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.
network Specify the range of addresses in an address pool. S6000 Syntax network network /prefix-length Parameters network/ prefixlength Specify a range of addresses. Prefix-length range is from 17 to 31. Defaults none Command Modes DHCP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series and S-Series. show ip dhcp binding Display the DHCP binding table. S6000 Syntax show ip dhcp binding Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series and S-Series. show ip dhcp conflict Display the address conflict log. S6000 Syntax show ip dhcp conflict address Parameters address Display a particular conflict log entry.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series and S-Series. Commands to Configure Secure DHCP DHCP, as defined by RFC 2131, provides no authentication or security mechanisms. Secure DHCP is a suite of features that protects networks that use dynamic address allocation from spoofing and attacks.
Defaults Disabled Command Modes Command History • INTERFACE • INTERFACE PORT-CHANNEL This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.6(0.0) Added the keywords discard-counters, interface, and the variable interface on the S4810, S4820T, S5000, S6000, Z9000, Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.
ip dhcp relay Enable Option 82. Syntax ip dhcp relay information-option [remote-id | trust-downstream] Parameters remote-id Configure the system to enable the remote-id string in option-82. trust-downstream Configure the system to trust Option 82 when it is received from the previous-hop router. Defaults Disabled Command Modes CONFIGURATION Command History This guide is platform-specific.
Usage Information Version Description 8.3.1.0 Introduced on the E-Series. 8.2.1.0 Introduced on the C-Series and S-Series on Layer 2 interfaces. 7.8.1.0 Introduced on the C-Series and S-Series on Layer 3 interfaces. When enabled, no learning takes place until you enable snooping on a VLAN. After disabling DHCP snooping, the binding table deletes and Option 82, IP Source Guard, and Dynamic ARP Inspection are disabled. Introduced in Dell Networking OS version 7.8.1.
Version Description 9.7(0.0) Introduced on the S4810, S4820T, S6000 and Z-Series. ip dhcp snooping binding Create a static entry in the DHCP binding table. S6000 Syntax [no] ip dhcp snooping binding mac address vlan-id vlan-id ip ip-address interface type slot/port lease number Parameters Defaults mac address Enter the keyword mac then the MAC address of the host to which the server is leasing the IP address. vlan-id vlan-id Enter the keywords vlan-id then the VLAN to which the host belongs.
Related Commands Version Description 7.8.1.0 Introduced on the C-Series and S-Series. show ip dhcp snooping — displays the contents of the DHCP binding table. IPv6 DHCP Snooping Binding Create a static DHCP snooping binding entry in the snooping database.
ip dhcp snooping database Delay writing the binding table for a specified time. S6000 Syntax ip dhcp snooping database write-delay minutes Parameters minutes The range is from 5 to 21600. Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Version Description 9.7(0.0) Introduced on the S4810, S4820T, S6000 and Z-Series. ip dhcp snooping database renew Renew the binding table. S6000 Syntax ip dhcp snooping database renew Defaults none Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
ip dhcp snooping trust Configure an interface as trusted. S6000 Syntax [no] ip dhcp snooping trust Defaults Untrusted Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
vlan vlan-id Defaults Disabled Command Modes INTERFACE (OPTIONAL) SAV validates the source IP address along with the source VLAN ID against the DHCP snooping binding table. INTERFACE PORTCHANNEL Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.
NOTE: Adds the VPN/VRF related sub-options into the relay agent information option(82). When DHCP broadcasts are forwarded by the relay agent from clients to DHCP server. Default Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.
Version Description 8.3.1.0 Introduced on the E-Series. 7.2.1.0 Introduced on the C-Series and S-Series. ipv6 dhcp snooping verify mac-address Syntax [no] ipv6 dhcp snooping verify mac-address To disable verify source mac-address against IPv6 DHCP packet MAC address, use the no ipv6 dhcp snooping verify mac-address command. Defaults Disabled Command Modes CONFIGURATION Command History This guide is platform-specific.
Usage Information Use this command on the interfaces where the DHCP clients are connected to forward the packets from clients to DHCP server and vice-versa. Example Dell(conf-if-te-1/12)#ip helper-address vrf jay 10.0.0.2 ipv6 helper-address Configures the ipv6 DHCP helper addresses without VRF. Syntax [no] ipv6 helper-address ipv6-address To delete the ipv6 helper address, use the [no] ipv6 helper-address ipv6-address command.
interface interface (OPTIONAL) Specifies an interface to show the discard counters. Enter any of the following keywords and slot/port or number information: Defaults Command Modes Command History • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a port channel interface, enter the keywords port-channel then a number.
permit host 0.0.0.0 host 00:00:00:00:00:00 count (0 packets) permit vlan 10 host 1.1.1.1 host 00:00:00:00:01:01 count (0 packets) permit vlan 10 host 1.1.1.2 host 00:00:00:00:01:02 count (0 packets) permit vlan 10 host 1.1.1.3 host 00:00:00:00:01:03 count (0 packets) ipmac-vlan sav access-list on Port-channel 10 on stack-unit 1 Total cam count 5 permit host 0.0.0.0 host 00:00:00:00:00:00 count (0 packets) permit vlan 10 host 1.1.1.1 host 00:00:00:00:01:01 count (0 packets) permit vlan 10 host 1.1.1.
Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S4810, S4820T, S6000 and Z-Series. Dell#show ipv6 dhcp snooping IPv6 DHCP Snooping IPv6 DHCP Snooping Mac Verification : Enabled. : Disabled.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Introduced on the S-Series and Z-Series. Usage Information Use this command to associate name server IP addresses to a specific VRF.
ip domain-list Adds a domain name to the DNS list. This domain name is appended to incomplete host names in DNS requests corresponding to a specific VRF. Syntax ip domain-list [vrf vrf-name] name To remove a domain name from DNS list, use the no ip domain-list [vrf vrf-name] name command. Parameters vrf vrf-name (Optional) Enter the key word vrf and then the name of the VRF to add a domain name to the DNS list corresponding to that VRF.
ip-address Enter the IP address of the name server in dotted decimal format. Defaults None Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Introduced on the S-Series and Z-Series.
15 Equal Cost Multi-Path (ECMP) Equal cost multi-path (ECMP) is supported on the Dell Networking OS. ecmp-group Provides a mechanism to monitor traffic distribution on an ECMP link bundle. A system log is generated when the standard deviation of traffic distribution on a member link exceeds a defined threshold. S6000 Syntax ecmp-group {ecmp-group-id interface interface | link-bundle-monitor} To remove the selected interface, use the ecmp-group no interface command.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.10.0 Introduced on the S4810. Using CONFIGURATION mode, create an ECMP group ID. You can then assign interfaces to the ECMP group using CONFIGURATION ECMP-GROUP mode. You can also enable on the port-channel configuration using the CONFIGURATION ECMP-GROUP command mode. hash-algorithm Changes the hash algorithm used to distribute traffic flows across a Port Channel. The ECMP and LAG options are supported on the Z-Series.
hg {crc16 | crc16cc | crc32MSB | crc32LSB | xor1 | xor2 | xor4 | xor8 | xor16} stack-unit stack-unit-number | port-set port-pipe • xor8: Use CRC16_BISYNC_AND_XOR8 — Upper 8 bits of CRC16-BISYNC and lower 8 bits of xor8 • xor16: Use CR16 — 16 bit XOR Z-Series only: Enter the keyword hg then one of the following options: • crc16: Use CRC16_BISYNC — 16 bit CRC16-bisync polynomial (default) • crc16cc: Use CRC16_CCITT — 16 bit CRC16 using CRC16-CCITT polynomial • crc32MSB: Use CRC32_UPPER — MSB 16 bits
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.10.0 Introduced on the S4810. 8.1.1.
ip ecmp-group Enable and specify the maximum number of ecmp that the L3 CAM hold for a route, By default, when maximum paths are not configured, the CAM can hold a maximum of 16 ecmp per route. S6000 Syntax ip ecmp-group {maximum-paths | {number} {path-fallback} To negate a command, use the no ip ecmp-group maximum-paths {number} command. Parameters maximum-paths Specify the maximum number of ECMP for a route. The range is 2 to 64. path-fallback Use the keywords path-fallback to enable this feature.
If disabled, the CLI would inform the FIB to re-program the destination prefix paths with no weights or regular ECMP.
link-bundle-monitor enable Provides a mechanism to enable monitoring of traffic distribution on an ECMP link bundle. S6000 Syntax link-bundle-monitor enable To exit from ECMP group mode, use the exit command. Command Modes Command History • ECMP-GROUP • PORT-CHANNEL INTERFACE This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
16 Flex Hash and Optimized Boot-Up This chapter describes the Flex Hash and fast-boot enhancements. load-balance ingress-port enable Enable the Flex hash functionality. This utility is supported on the S6000 platform. Syntax load-balance ingress-port enable To disable the Flex hash capability, use the no version of this command. Default None Command Modes CONFIGURATION mode Command History Usage Information Version 9.3(0.0) Introduced on the S6000 platform.
Parameters ipv4 Denotes whether Flex Hash needs to be enabled for IPv4 packets. ipv6 Denotes whether Flex Hash needs to be enabled for IPv6 packets. protocol number Represents the Outer IPv4 protocol field in case of IPv4 packets, and the Outer IPv6 next header field in case of IPv6 packets. The ipv4/ipv6 keyword and the IP protocol value are used as keys to identify if a duplicate flex hash configuration is already present. Duplicate flex hash configuration is not possible.
reload-type fastboot Restart the system with optimized booting-time functionality enabled. When you restart the device in fast boot mode, traffic disruption is reduced significantly and the system operations to service the data traffic are restored in a seamless way. C9000 Series Syntax reload-type fastboot Parameters fastboot Enable the system to restart the next time with the optimized booting-time capability Defaults By default, the device reloads in Jumpstart or BMP mode.
Usage Information Version Description 9.3(0.0) Introduced on the S6000. You can configure the optimal switchover functionality for LACP even if you do not enable the fast boot mode on the system. You must configure the long timeout mechanism for the LACP session to enable the fast boot capability to operate properly. This command applies to dynamic port-channel interfaces only.
17 FIP Snooping To enable the FCoE Transit feature and configure FIP snooping, use the following Dell Networking Operating System commands on the platform. In a converged Ethernet network, a switch can operate as an intermediate Ethernet bridge to snoop on FIP packets during the login process on Fibre Channel over Ethernet (FCoE) forwarders (FCFs).
clear fip-snooping statistics Clears the statistics on the FIP packets snooped on all VLANs, a specified VLAN, or a specified port interface. Syntax Parameters clear fip-snooping statistics [interface vlan vlan-id | interface fortyGigEport-type port/slot | interface port-channel port-channel-number] vlan-id Enter the VLAN ID of the FIP packet statistics to be cleared. port-type port/slot Enter the port-type and slot number of the FIP packet statistics to be cleared.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the Z9500 and S6000-ON. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. debug fip snooping rx Enable debugging for FIP snooping receive-specific packets.
Version Description 9.7(0.0) Introduced on the Z9500 and S6000-ON. 9.2(0.2) Introduced on the S4810 and S4820T. Added the receive parameters packettype and interfaces and their options. feature fip-snooping Enable FCoE transit and FIP snooping on a switch. Syntax feature fip-snooping To disable the FCoE transit feature, use the no feature fip-snooping command. Defaults Disabled Command Modes CONFIGURATION Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the Z9500 and S6000-ON. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. The maximum number of FCFs supported per FIP snooping-enabled VLAN is four.
fip-snooping max-sessions-per-enodemac Configure the maximum session limit per ENode MAC address. Syntax fip-snooping max—sessions—per—enode—mac max-sessions-value To return the configured maximum sessions to the default value, use the no fip-snooping max— sessions—per—enode—mac command. Parameters max-sessions-value Enter the maximum number of sessions allowed per ENode MAC address. The range is from 1 to 64.
fip-snooping port-mode fcoe-trusted Configure the port for bridge-to-bridge links. Syntax fip-snooping port-mode fcoe-trusted To remove the bridge-to-bridge link configuration from the port, use the no fip-snooping port-mode fcoe-trusted command. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Example Dell# show fip-snooping config FIP Snooping Feature enabled Status: Enabled FIP Snooping Global enabled Status: Enabled Global FC-MAP Value: 0X0EFC00 FIP Snooping enabled VLANs VLAN Enabled FC-MAP ----------------100 TRUE 0X0EFC00 show fip-snooping enode Display information on the ENodes in FIP-snooped sessions, including the ENode interface and MAC address, FCF MAC address, VLAN ID and FC-ID.
--------- --------------- ------- ---- ----d4:ae:52:1b:e3:cd Te 1/11 54:7f:ee:37:34:40 100 62:00:11 show fip-snooping fcf Display information on the FCFs in FIP-snooped sessions, including the FCF interface and MAC address, FCF interface, VLAN ID, FC-MAP value, FKA advertisement period, and number of ENodes connected. Syntax show fip-snooping fcf [fcf-mac-address] Parameters Command Modes Command History fcf-mac-address • EXEC • EXEC Privilege Enter the MAC address of the FCF to display.
show fip-snooping statistics Display statistics on the FIP packets snooped on all interfaces, including VLANs, physical ports, and port channels. Syntax Parameters Command Modes Command History show fip-snooping statistics [interface vlan vlan-id | interface port-type port/slot | interface port-channel port-channel-number] vlan-id Enter the VLAN ID of the FIP packet statistics displays. port-type port/slot Enter the port-type and slot number of the FIP packet statistics displays.
Example 530 Field Description Number of VN Port Keep Alives Number of FIP-snoop VN port (Virtual N-port) keep-alive frames received on the interface Number of Multicast Discovery Advertisements Number of FIP-snoop multicast discovery advertisements received on the interface. Number of Unicast Discovery Advertisements Number of FIP-snoop unicast discovery advertisements received on the interface. Number of FLOGI Accepts Number of FIP FLOGI accept frames received on the interface.
Number of Session failures due to Hardware Config :0 Dell(conf)# Dell# show fip-snooping statistics int tengigabitethernet 1/11 Number of Vlan Requests :1 Number of Vlan Notifications :0 Number of Multicast Discovery Solicits :1 Number of Unicast Discovery Solicits :0 Number of FLOGI :1 Number of FDISC :16 Number of FLOGO :0 Number of Enode Keep Alive :4416 Number of VN Port Keep Alive :3136 Number of Multicast Discovery Advertisement :0 Number of Unicast Discovery Advertisement :0 Number of FLOGI Accepts :
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the Z9500 and S6000-ON. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810.
show fips status Display the FIPs status on the platform. Syntax show fips status Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810.
18 Force10 Resilient Ring Protocol (FRRP) Force10 resilient ring protocol (FRRP) is supported on Dell Networking OS. FRRP is a proprietary protocol for that offers fast convergence in a Layer 2 network without having to run the spanning tree protocol (STP). The resilient ring protocol is an efficient protocol that transmits a high-speed token across a ring to verify the link status. All the intelligence is contained in the master node with practically no intelligence required of the transit mode.
Usage Information Example Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series. 7.5.1.0 Introduced. Executing this command without the optional ring-id command clears the statistics counters on all the available rings. Dell Networking OS requires a command line confirmation before the command executes.
Command Modes CONFIGURATION (conf-frrp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Version Description 8.2.1.0 Introduced on the C-Series. 7.4.1.0 Introduced. disable Disable the resilient ring protocol. S6000 Syntax disable To enable the Resilient Ring Protocol, use the no disable command. Defaults Disabled Command Modes CONFIGURATION (conf-frrp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Parameters primary interface secondary interface control-vlan vlan-id Enter the keyword primary to configure the primary interface then one of the following interfaces and slot/port information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a port channel interface, enter the keywords port-channel then a number.
member-vlan Specify the member VLAN identification numbers. S6000 Syntax member-vlan {vlan-range} To return to the default, use the no member-vlan [vlan-range] command. Parameters vlan-range Enter the member VLANs using VLAN IDs (separated by commas), a range of VLAN IDs (separated by a hyphen), a single VLAN ID, or a combination. For example: VLAN IDs (comma-separated): 3, 4, 6. Range (hyphen-separated): 5-10. Combination: 3, 4, 5-10, 8.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series. 7.4.1.
Usage Information This command places you into the resilient ring protocol. After executing this command, the command line prompt changes to conf-frrp. show frrp Display the resilient ring protocol configuration. S6000 Syntax Parameters show frrp [ring-id [summary]] | [summary] ring-id Enter the ring identification number. The range is from 1 to 255 summary (OPTIONAL) Enter the keyword summary to view just a summarized version of the Ring configuration.
• The number of state change counters Example (Summary) Dell#show frrp summary Ring-ID State Mode Ctrl_Vlan Member_Vlans ---------------------------------------------2 UP Master 2 11-20, 25,27-30 31 UP Transit 31 40-41 50 Down Transit 50 32 Dell# Example (1) Dell#show frrp 1 Ring protocol 1 is in Master mode Ring Protocol Interface: Primary : TenGigabitEthernet 1/16 State: Forwarding Secondary: Port-channel 100 State: Blocking Control Vlan: 1 Ring protocol Timers: Hello-Interval 50 msec Dead-Interval 150
NOTE: The configured dead interval must be at least three times the hello interval. Defaults • 500 ms for hello-interval milliseconds • 1500 ms for dead-intervalmilliseconds Command Modes CONFIGURATION (conf-frrp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
19 GARP VLAN Registration (GVRP) The Dell Networking operating system supports the basic GVRP commands on the Dell Networking OS. The generic attribute registration protocol (GARP) mechanism allows the configuration of a GARP participant to propagate through a network quickly. A GARP participant registers or de-registers its attributes with other participants by making or withdrawing declarations of attributes.
clear gvrp statistics Clear GVRP statistics on an interface. S6000 Syntax Parameters clear gvrp statistics interface interface interface interface Enter the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a port channel interface, enter the keywords port-channel then a number.
To disable debugging, use the no debug gvrp {config | events | pdu} command. Parameters config Enter the keyword config to enable debugging on the GVRP configuration. event Enter the keyword event to enable debugging on the JOIN/LEAVE events. pdu Enter the keyword pdu then one of the following Interface keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on C-Series, E-Series, and S-Series gvrp enable — enables GVRP on physical interfaces and LAGs. protocol gvrp — access GVRP protocol.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
Related Commands Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on C-Series, E-Series, and S-Series disable — globally disables GVRP. gvrp registration Configure the GVRP register type. S6000 Syntax gvrp registration {fixed | normal | forbidden} To return to the default, use the gvrp register normal command.
Usage Information Fixed registration prevents an interface, configured using the command line, to belong to a VLAN (static configuration) from being unconfigured when it receives a Leave message. Therefore, Registration mode on that interface is fixed. Normal registration is the default registration. The port’s membership in the VLAN depends on GVRP. The interface becomes a member of a VLAN after learning about the VLAN through GVRP.
show config Display the global GVRP configuration. S6000 Syntax show config Command Modes CONFIGURATION-GVRP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on C-Series, E-Series, and S-Series Example Dell#show garp timers GARP Timers Value (milliseconds) ---------------------------------------Join Timer 200 Leave Timer 600 LeaveAll Timer 10000 Dell# Related Commands garp timers — sets the intervals (in milliseconds) for sending GARP messages.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on C-Series, E-Series, and S-Series Usage Information If no ports are GVRP participants, the message output changes from GVRP Participants running on to GVRP Participants running on no ports. Example R3#show gvrp brief GVRP Feature is currently enabled.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.11.1 Introduced on the Z9000. 7.6.1.
20 ICMP Message Types This chapter lists and describes the possible ICMP message type resulting from a ping. The first three columns list the possible symbol or type/code. For example, you would receive a ! or 03 as an echo reply from your ping. ICMP Messages and Their Definitions. Symbol Type Code . Query Error Timeout (no reply) ! 0 U 3 C Description 4 3 echo reply . destination unreachable: 0 network unreachable . 1 host unreachable . 2 protocol unreachable .
Symbol & Type Code Description Query 8 0 echo request . 9 0 router advertisement . 10 0 router solicitation . 11 time exceeded: 0 time-to-live equals 0 during transit . 1 time-to-live equals 0 during reassembly . 12 556 Error parameter problem: 1 IP header bad (catchall error) . 2 required option missing . 13 0 timestamp request . 14 0 timestamp reply . 15 0 information request (obsolete) . 16 0 information reply (obsolete) . 17 0 address mask request .
21 Internet Group Management Protocol (IGMP) The IGMP commands are supported by the Dell Networking operating software on the Dell Networking OS. This chapter contains the following sections: • IGMP Commands • IGMP Snooping Commands IGMP Commands Dell Networking OS supports IGMPv1/v2/v3 and is compliant with RFC-3376.
• For a port channel interface, enter the keywords port-channel then a number. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Added support for VRF.
• For a port channel interface, enter the keywords port-channel then a number. Defaults Disabled. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the C-Series and S-Series. 7.6.1.0 Introduced on E-Series. The access list accepted is an extended ACL. To block IGMP reports from hosts, on a per-interface basis based on the group address and source address that you specify in the access list, use this feature.
deletion. In addition, this command provides a way to enable immediate-leave processing for specified groups. ip igmp last-member-query-interval Change the last member query interval, which is the Max Response Time inserted into Group-Specific Queries sent in response to Leave Group messages. This interval is also the interval between Group-Specific Query messages.
Parameters seconds Enter the number of seconds between queries sent out. The range is from 1 to 18000. The default is 60 seconds. Defaults 60 seconds Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.
Defaults 10 seconds Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9500. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 9.0.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Added support for VRF and Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. 7.5.1.0 Introduced on the E-Series. show ip igmp groups View the IGMP groups. S6000 Syntax Parameters show ip igmp [vrf vrf-name] groups [group-address [detail] | detail | interface [group-address [detail]]] vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to configure this setting on that VRF.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series and C-Series. 7.5.1.0 Expanded to support the detail option. E-Series legacy command. Usage Information This command displays the IGMP database, including configured entries for either all groups on all interfaces, all groups on specific interfaces, or specific groups on specific interfaces.
Example (Details) Dell#show ip igmp group details Interface Vlan 20 Group 232.1.1.5 Uptime 00:11:22 Expires Never Router mode INCLUDE Last reporter 35.0.0.2 Group source list Source address Expires 65.0.0.1 00:01:22 65.0.0.2 00:01:22 65.0.0.3 00:01:22 65.0.0.4 00:01:22 65.0.0.5 00:01:22 show ip igmp interface View information on the interfaces participating in IGMP.
Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series legacy command. Usage Information IGMP commands accept only non-VLAN interfaces — specifying VLAN does not yield results. The show ip igmp interface command does not display information corresponding to the loop-back interfaces.
show ip igmp ssm-map Display is a list of groups that are currently in the IGMP group table and contain SSM mapped sources. S6000 Syntax Parameters show ip igmp [vrf vrf-name] ssm-map [group] vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to configure this setting on that VRF. NOTE: Applies to specific VRF if input is provided, else applies to Default VRF.
IGMP Snooping Commands Dell Networking OS supports IGMP Snooping version 2 and 3 on all Dell Networking systems. Important Points to Remember for IGMP Snooping • Dell Networking OS supports version 1, version 2, and version 3 hosts. • Dell Networking OS IGMP snooping implementation is based on IP multicast address (not based on Layer 2 multicast mac address) and the IGMP snooping entries are in Layer 3 flow table not in Layer 2 forwarding information base (FIB).
• For a port channel interface, enter the keywords port-channel then a number. Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on S-Series and Z–Series.
ip igmp snooping enable Enable IGMP snooping on all or a single VLAN. This command is the master on/off switch to enable IGMP snooping. Syntax ip igmp snooping enable To disable IGMP snooping, use the no ip igmp snooping enable command. Defaults Disabled. Command Modes Command History • CONFIGURATION • INTERFACE VLAN This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9500. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 9.0.2.0 Introduced on the S6000. 8.3.19.
Version Description 8.2.1.0 Introduced on the C-Seris and S-Series. 7.7.1.0 Introduced on the E-Series. E-Series legacy command Usage Information On the C-Series and S-Series, unregistered multicast data traffic drops when you disable flooding; they do not forward the packets to multicast router ports. On the C-Series and S-Series, in order to disable Layer 2 multicast flooding, disable Layer 3 multicast (no ip multicast-routing).
Usage Information This last-member-query-interval is also the interval between successive Group-Specific Query messages. To change the last-member-query interval, use this command. ip igmp snooping mrouter Statically configure a VLAN member port as a multicast router interface. S6000 Syntax ip igmp snooping mrouter interface interface To delete a specific multicast router interface, use the no igmp snooping mrouter interface interface command.
ip igmp snooping querier Enable IGMP querier processing for the VLAN interface. S6000 Syntax ip igmp snooping querier To disable IGMP querier processing for the VLAN interface, use the no ip igmp snooping querier command. Defaults Not configured. Command Modes INTERFACE VLAN — (conf-if-vl-n) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
interface detail Command Modes Command History • EXEC • EXEC Privilege (OPTIONAL) Enter the interface type and slot/port information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383.
show ip igmp snooping mrouter Display multicast router interfaces. S6000 Syntax show ip igmp snooping mrouter [vlan number] Parameters Command Modes Command History vlan number • EXEC • EXEC Privilege Enter the keyword vlan then the vlan number. The range is from 1 to 4094. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
22 Interfaces The commands in this chapter are supported by Dell Networking operating software on the S6000 platform. This chapter contains the following sections: • Basic Interface Commands • Port Channel Commands This chapter contains the following sections: • Basic Interface Commands • Port Channel Commands • Time Domain Reflectometer (TDR) • UDP Broadcast Basic Interface Commands The following commands are for Physical, Loopback, and Null interfaces.
• For a tunnel interface, enter the keyword tunnel. The range is from 1 to 16383. vrrp [[ipv6] vrid] (OPTIONAL) Enter the keyword vrrp to clear the counters of all VRRP groups. To clear the counters of VRRP groups on all IPv6 interfaces, enter ipv6. To clear the counters of a specified group, enter a VRID number from 1 to 255. learning-limit (OPTIONAL) Enter the keywords learning-limit to clear unknown source address (SA) drop counters when MAC learning limit is configured on the interface.
clear dampening Clear the dampening counters on all the interfaces or just the specified interface. S6000 Syntax Parameters clear dampening [interface] interface (OPTIONAL) Enter any of the following keywords and slot/port or number to clear counters from a specified interface: • For a Port Channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
dampening Configure dampening on an interface. S6000 Syntax dampening [[[[half-life] [reuse-threshold]] [suppress-threshold]] [maxsuppress-time]] Parameters half-life Enter the number of seconds after which the penalty is decreased. The penalty decreases half after the half-life period expires. The range is from 1 to 30 seconds. The default is 5 seconds. reuse-threshold Enter a number as the reuse threshold, the penalty value below which the interface state is changed to “up”.
• max-suppress-time should be at least 4 times half-life NOTE: You cannot apply dampening on an interface that is monitoring traffic for other interfaces. Example Dell(conf-if-te-1/10)#dampening 20 800 4500 120 Dell(conf-if-te-1/10)# Related Commands clear dampening — clears the dampening counters on all the interfaces or just the specified interface. show interfaces dampening — displays interface dampening information. description Assign a descriptive text string to the interface.
• Entering a text string after the description command overwrites any previous text string that you previously configured as the description. • The shutdown and description commands are the only commands that you can configure on an interface that is a member of a port-channel. • Use the show interfaces description command to display descriptions configured for each interface. duplex (10/100 Interfaces) Configure duplex mode on any physical interfaces where the speed is set to 10/100.
flowcontrol Control how the system responds to and generates 802.3x pause frames on 10 Gig ports. Syntax flowcontrol rx {off | on} tx {off | on} [pause- threshold {<1-12480>] [resume-offset <1-12480>} The threshold commands are supported on S6000 only. To return to the default, use the no flowcontrol rx {off | on}tx {off on} threshold command. Parameters Parameters rx on Enter the keywords rx on to process the received flow control frames on this port. This is the default value for the receive side.
Usage Information The globally assigned 48-bit Multicast address 01-80-C2-00-00-01 is used to send and receive pause frames. To allow full duplex flow control, stations implementing the pause operation instruct the MAC to enable the reception of frames with a destination address equal to this multicast address. When a port receives traffic at a higher rate than it can process, the frames are stored in the port buffer. As a result, buffe usage increases.
on Related Commands on off off on on off on off on LocNegRx off off off off LocNegTx RemNegRx RemNegTx off off off off off off off off off off off off off off off off off off on off off off on off off off off off off on on on off off on on off off on on off on on on off off on on off off on on off off on on off off on on show running-config — displays the flow configuration parameters (non-default values only). show interfaces — displays the negotiated flow control parameters.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Added the support for interfaces. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
interface group Create or delete group of VLANs with a single command. You can also use this command to apply a set of configurations on a group of interfaces. S6000 Syntax interface group [fortyGigE slot/port { - port }| tengigabitethernet slot/ port { - port } | vlan vlanid {- vlanid } ] To delete a range of VLANs, use the following command: no interface group vlan vlanid {vlanid} Parameters interface, interface,...
Dell(conf)# interface group vlan 1 - 2 , tengigabitethernet 1/10 Dell(conf-if-group-vl-1-2,te-1/10)# no shutdown Dell(conf-if-group-vl-1-2,te-1/10)# end Related Commands interface range — Configures a range of interfaces. interface vlan — Configures a VLAN. interface loopback Configure a Loopback interface. S6000 Syntax interface loopback number To remove a loopback interface, use the no interface loopback number command. Parameters number Enter a number as the interface number.
interface ManagementEthernet Configure the Management port on the system (either the Primary or Standby RPM). S6000 Syntax Parameters interface ManagementEthernet slot/port slot/port Enter the keyword ManagementEthernet, then the slot number (0 or 1) and port number zero (0). Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
interface null Configure a Null interface on the switch. S6000 Syntax interface null number Parameters number Enter zero (0) as the Null interface number. Defaults Not configured; number = 0 Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.
interface range This command permits configuration of a range of interfaces to which subsequent commands are applied (bulk configuration). Using the interface range command, you can enter identical commands for a range of interface. S6000 Syntax Parameters interface range interface {slot/port | port} — port}, interface {slot/port | port} — port},... interface {slot/port | port} — port}, interface {slot/port | port} — port},...
Usage Information When creating an interface range, interfaces appear in the order they are entered; they are not sorted. The command verifies that interfaces are present (physical) or configured (logical). Important Points to Remember: • Bulk configuration is created if at least one interface is valid. • Non-existing interfaces are excluded from the bulk configuration with a warning message. • The interface range prompt includes interface types with slot/port information for valid interfaces.
Vlan 2–100, Port 1–25 Dell(config-if-range-te-1/1-2,te-5/1-23,vl-2-100,po-1-25)# no shutdown Dell(config-if-range-te-5/1-24,te-1/1-2,vl-2-100,po-1-25)# Related Commands interface port-channel — configures a port channel group. interface vlan — configures a VLAN interface. show config (from INTERFACE RANGE mode) — shows the bulk configuration interfaces. show range — shows the bulk configuration ranges. interface range macro (define) — defines a macro for an interface-range.
Example (Single Range) Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.2.1.0 Added support for 4093 VLANs on E-Series ExaScale. Prior releases supported 2094. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-Version 6.1.1.0 Introduced on the E-Series.
Example (Single Range) Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.0 Introduced This example shows the macro named test that was defined earlier.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. For more information about VLANs and the commands to configure them, refer to the Virtual LAN (VLAN) Commands section of the Layer 2 chapter. FTP, TFTP, and SNMP operations are not supported on a VLAN. MAC ACLs are not supported in VLANs. IP ACLs are supported. For more information, refer to the Access Control Lists (ACL) chapter.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module. If you configure the interface type as CR4 with auto-negotiation enabled, also configure CR4 with autonegotiation. Many DAC cable link issues are resolved by setting the interface type as CR4. If the CR4 optic fails to come up, use the autoneg option.
Usage Information When you configure keepalive, the system sends a self-addressed packet out of the configured interface to verify that the far end of a WAN link is up. When you configure no keepalive, the system does not send keepalive packets and so the local end of a WAN link remains up even if the remote end is down. monitor interface Monitor counters on a single interface or all interfaces on a line card. The screen is refreshed every five seconds and the CLI prompt disappears.
The following are the monitor command menu options. Example (Single Interface) Key Description systest-3 Displays the host name assigned to the system. monitor time Displays the amount of time since the monitor interface command was entered. time Displays the amount of time the chassis is up (since last reboot). m Change the view from a single interface to all interfaces on the line card or visaversa. c Refresh the view. b Change the counters displayed from Packets on the interface to Bytes.
Te 0/0 Down 0 0 0 0 Te 0/1 Down 0 0 0 0 Te 0/2 Up 61512 52 66160 42 Te 0/3 Up 63086 20 9405888 24 Te 0/4 Up 14697471418 2661481 13392989657 2661385 Te 0/5 Up 3759 3 161959604 832816 Te 0/6 Up 4070 3 8680346 5 Te 0/7 Up 61934 34 138734357 72 Te 0/8 Up 61427 1 59960 1 Te 0/9 Up 62039 53 104239232 3 Te 0/10 Up 17740044091 372 7373849244 79 Te 0/11 Up 18182889225 44 7184747584 138 Te 0/12 Up 18182682056 0 3682 1 Te 0/13 Up 18182681434 43 6592378911 144 Te 0/14 Up 61349 55 86281941 15 Te 0/15 Up 59808 58 62060 2
Usage Information Version Description 8.1.1.0 Introduced on the E-Series ExaScale. 7.5.1.0 Introduced on the C-Series. pre-Version 6.2.1.0 Introduced on the E-Series. If the packet includes a Layer 2 header, the difference between the link MTU and IP MTU (ip mtu command) must be enough bytes to include the Layer 2 header. When you enter the no mtu command, Dell Networking OS reduces the IP MTU value to 1536 bytes. Link MTU and IP MTU considerations for port channels and VLANs are as follows.
To disable auto-negotiation, use the no negotiation auto command. Defaults Enabled. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Example (Master/ Slave) Dell(conf)# interface tengigabitethernet 1/1 Dell(conf-if)#neg auto Dell(conf-if-autoneg)# ? end Exit from configuration mode exit Exit from autoneg configuration mode mode Specify autoneg mode no Negate a command or set its defaults show Show autoneg configuration information Dell(conf-if-autoneg)#mode ? forced-master Force port to master mode forced-slave Force port to slave mode Dell(conf-if-autoneg)# Example (Configured) Dell#show interfaces configured TenGigabitEthernet 13/18
portmode hybrid To accept both tagged and untagged frames, set a physical port or port-channel. A port configured this way is identified as a hybrid port in report displays. S6000 Syntax portmode hybrid To return a port to accept either tagged or untagged frames (non-hybrid), use the no portmode hybrid command. Defaults non-hybrid Command Modes INTERFACE (conf-if-interface-slot/port) Command History This guide is platform-specific.
Example Dell(conf)#interface tengigabitethernet 7/1 Dell(conf-if-gi-7/0)#portmode hybrid Dell(conf-if-gi-7/0)#interface vlan 10 Dell(conf-if-vl-10)#untagged tengigabitethernet 7/1 Dell(conf-if-vl-10)#interface vlan 20 Dell(conf-if-vl-20)#tagged tengigabitethernet 7/1 Dell(conf-if-vl-20)# Example Dell(conf-if-vl-20)#do show interfaces switchport Name: TenGigabitEthernet 7/1 802.
Version Description 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced Usage Information The output of the show interfaces command displays the configured rate interval, along with the collected traffic data. Related Commands show interfaces — displays information on physical and virtual interfaces. show config Display the interface configuration.
Command History Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.1) Introduced on the S6000. Usage Information In order for the speed information corresponding to an interface to appear in the show command output, you must first configure the speed of that interface using the speed command.
! interface TenGigabitEthernet 1/2 no ip address switchport no shutdown Dell(conf-if-range-gi-1/1-2)# show interfaces Display information on a specific physical interface or virtual interface. S6000 Syntax show interfaces interface Parameters Command Modes Command History 610 Interfaces interface • EXEC • EXEC Privilege Enter one of the following keywords and slot/port or number information: • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383.
Usage Information Version Description 8.2.1.0 Added support for 4093 VLANs on the E-Series ExaScale. Prior releases supported 2094. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Output expanded to include SFP+ media on the C-Series. 7.6.1.0 Introduced on the S Series. 7.5.1.0 Introduced on the C-Series. 6.4.1.0 Changed the organization of the display output. 6.3.1.0 Added the Pluggable Media Type field in the E-Series TeraScale output.
Line Description MTU 1554... Displays link and IP MTU information. LineSpeed Displays the interface’s line speed, duplex mode, and negotiation mode. ARP type:... Displays the ARP type and the ARP timeout value for the interface. Last clearing... Displays the time when the show interfaces counters where cleared. Queuing strategy... States the packet queuing strategy. FIFO means first in first out.
Example Dell#show interfaces TenGigabitEthernet 2/1 is down, line protocol is down Hardware is DellForce10Eth, address is 00:01:e8:8b:3d:e7 Current address is 00:01:e8:8b:3d:e7 Pluggable media present, Media type is unknown Wavelength unknown Interface index is 100992002 Internet address is not set MTU 1554 bytes, IP MTU 1500 bytes LineSpeed auto Flowcontrol rx on tx off ARP type: ARPA, ARP Timeout 04:00:00 Last clearing of "show interface" counters 3d17h53m Queueing strategy: fifo Input Statistics: 0 pack
Input 00.00 Mbits/sec, 0 packets/sec, 0.00% of line-rate Output 00.00 Mbits/sec, 0 packets/sec,0.
Input 791 packets, 62913 bytes, 775 multicast Received 0 errors, 0 discarded Output 21 packets, 3300 bytes, 20 multicast Output 0 errors, 0 invalid protocol Time since last interface status change: 00:06:03 Example (OpenFlow instance) Dell#show interfaces vlan 6 Vlan 6 is down, line protocol is down Address is 00:01:e8:8a:e1:8c, Current address is 00:01:e8:8a:e1:8c Interface index is 1107525638 of-instance: 2 Internet address is not set MTU 1554 bytes, IP MTU 1500 bytes LineSpeed auto ARP type: ARPA, ARP T
Command History Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.4.1.0 Changed the organization of the display output.
• For a port channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. summary (OPTIONAL) Enter the keyword summary to display the current summary of dampening data, including the number of interfaces configured and the number of interfaces suppressed, if any.
show interfaces stack-unit Display information on all interfaces on a specific S-Series or Z-Series stack member. S6000 Syntax show interfaces stack-unit unit-number Parameters Command Modes Command History unit-number • EXEC • EXEC Privilege Enter the stack member number. The range is from 0 to 5 for the S6000 This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Hardware is Force10Eth, address is 00:01:e8:4c:f2:83 Current address is 00:01:e8:4c:f2:83 !-------------output truncated ----------------! Related Commands show hardware stack-unit — displays data plane and management plane input/output statistics. show interfaces — displays information on a specific physical interface or virtual interface.
Example Version Description 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.5.1.0 Introduced on the E-Series.
Mode of IPv4 Address Assignment: NONE DHCP Client-ID: 90b11cf499ce MTU 1554 bytes, IP MTU 1500 bytes LineSpeed auto ARP type: ARPA, ARP Timeout 04:00:00 Last clearing of "show interface" counters 2d17h26m Queueing strategy: fifo Time since last interface status change: 2d17h26m Input Statistics: 0 packets, 0 bytes Output Statistics: 0 packets, 0 bytes, 0 underruns Related Commands show interfaces — displays information on a specific physical interface or virtual interface.
76 76 80 80 84 84 88 88 92 92 100 100 108 108 116 116 124 124 Dell# Related Commands stack-unit portmode — splits a single 40G port into four-10G ports stack-unit quad-port-profile Configures the list of dynamic fan-out capable ports. Syntax stack-unit [stack-unit number] quad-port-profile [default|<0–124>] To remove the quad-port configuration, use the [no] stack-unit[stack-unit number] quadport-profile [default|<0–124>]command syntax.
stack-unit unit-id Command Modes Command History • EXEC • EXEC Privilege • For a port channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a backup interface for this interface, enter the keyword backup.
Native VlanId: 20 Name: TenGigabitEthernet 13/2 802.1QTagged: True Vlan membership: Vlan 2 Name: TenGigabitEthernet 13/3 802.1QTagged: True Vlan membership: Vlan 2 Name: TenGigabitEthernet 13/4 802.1QTagged: True Vlan membership: Vlan 2 --More-Related Commands interface — configures a physical interface on the switch. show ip interface — displays Layer 3 information about the interfaces. show interfaces — displays information on a specific physical interface or virtual interface.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Output augmented with diagnostic data for pluggable media. 7.7.1.0 Removed three fields in the output: Vendor Name, Vendor OUI, and Vendor PN. 7.6.1.0 Introduced on the C-Series and S-Series. 6.5.4.0 Introduced on the E-Series.
Interfaces Line Description RX Power High Warning threshold Factory-defined setting. Value can differ between SFP and SFP+. Temp Low Warning threshold Factory-defined setting. Value can differ between SFP and SFP+. Voltage Low Warning threshold Factory-defined setting. Value can differ between SFP and SFP+. Bias Low Warning threshold Factory-defined setting. Value can differ between SFP and SFP+. TX Power Low Warning threshold Factory-defined setting. Value can differ between SFP and SFP+.
Example Line Description Tx Bias High Alarm Flag This can be either true or false, depending on the present Tx bias current value displayed above. Tx Power High Alarm Flag This can be either true or false, depending on the Current Tx bias power value displayed above. Rx Power High Alarm Flag This can be either true or false, depending on the Current Rx power value displayed above.
SFP SFP SFP SFP SFP SFP SFP SFP SFP SFP SFP SFP SFP SFP SFP SFP 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 BR Nominal = 0x15 Length(9um) Km = 0x00 Length(9um) 100m = 0x00 Length(50um) 10m = 0x1e Length(62.
Related Commands interface — configures a physical interface on the switch. show ip interface — displays Layer 3 information about the interfaces. show interfaces — displays information on a specific physical interface or virtual interface. show inventory (S-Series and Z-Series) — displays the switch type, components (including media), Dell Networking OS version including hardware identification numbers and configured protocols.
shutdown Disable an interface. S6000 Syntax shutdown To activate an interface, use the no shutdown command. Defaults The interface is disabled. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
speed (Management interface) Set the speed for the Management interface. S6000 Syntax speed {10 | 100 | 1000 | auto} To return to the default setting, use the no speed command. Parameters 10 Enter the keyword 10 to set the interface’s speed to 10 Mb/s. 100 Enter the keyword 100 to set the interface’s speed to 10/100 Mb/s. 1000 Enter the keyword 1000 to set the interface to auto-negotiate its speed. auto Enter the keyword auto to set the interface to auto-negotiate its speed.
stack-unit portmode You can split a single 40G port into four 10G ports without reload.. S6000 Syntax stack-unit stack-unit port number portmode quad Parameters stack-unit Enter the stack member unit identifier of the stack member to reset. For the S6000, the range is from 0 to 5. number Enter the port number of the 40G port to be split. Defaults Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific.
switchport Place an interface in Layer 2 mode. S6000 Syntax switchport [backup interface {gigabit slot/port | tengigabit slot/port | fortyGigE slot/port | port-channel number}] To remove an interface from Layer 2 mode and place it in Layer 3 mode, enter the no switchport command. If a switchport backup interface is configured, first remove the backup configuration.
Usage Information Version Description pre-Version 6.2.1.0 Introduced on the E-Series. If an IP address or VRRP group is assigned to the interface, you cannot use the switchport command on the interface. To use the switchport command on an interface, only the no ip address and no shutdown statements must be listed in the show config output. When you enter the switchport command, the interface is automatically added to the default VLAN.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.
order of the channel members configuration to change the designated speed. For more information about Port Channels, refer to the Dell Networking OS Configuration Guide. Related Commands description — assigns a descriptive text string to the interface. interface port-channel — creates a Port Channel interface. shutdown — disables/enables the port channel. group Group two LAGs in a supergroup (“fate-sharing group” or “failover group”).
interface port-channel Create a Port Channel interface, which is a link aggregation group (LAG) containing 16 physical interfaces on the S-Series. S6000 Syntax interface port-channel channel-number To delete a Port Channel, use the no interface port-channel channel-number command. Parameters channel-number For a Port Channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. Defaults Not configured.
If the stack—unit card is in a Jumbo mode chassis, you can also configure the mtu and ip mtu commands. The Link MTU and IP MTU values configured on the channel members must be greater than the Link MTU and IP MTU values configured on the Port Channel interface. NOTE: In a Jumbo-enabled system, all members of a Port Channel must be configured with the same link MTU values and the same IP MTU values.
Usage Information Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-Version 6.2.1.0 Introduced on the E-Series. If you use this command to configure the minimum number of links in a LAG that must be in “oper up” status, the LAG must have at least that number of “oper up” links before it can be declared as up. For example, if the required minimum is four, and only three are up, the LAG is considered down.
show interfaces port-channel Display information on configured Port Channel groups. S6000 Syntax show interfaces port-channel [channel-number] [brief] Parameters Command Modes Command History channel-number For a Port Channel interface, enter the keyword port-channel then a number. For the C-Series and S-Series, the range is from 1 to 128.
Example Field Description LineSpeed Displays the interface’s line speed. For a port channel interface, it is the line speed of the interfaces in the port channel. Members in this... Displays the interfaces belonging to this port channel. ARP type:... Displays the ARP type and the ARP timeout value for the interface. Last clearing... Displays the time when the show interfaces counters were cleared. Queueing strategy. States the packet queuing strategy. FIFO means first in first out.
Field Description LAG Lists the port channel number. Mode Lists the mode: Status Example • L3 — for Layer 3 • L2 — for Layer 2 Displays the status of the port channel. • down — if the port channel is disabled (shutdown) • up — if the port channel is enabled (no shutdown) Uptime Displays the age of the port channel in hours:minutes:seconds. Ports Lists the interfaces assigned to this port channel. (untitled) Displays the status of the physical interfaces (up or down).
• For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. source-ip address Enter the keywords source-ip then the IP source address in IP address format. destination-ip address Enter the keywords destination-ip then the IP destination address in IP address format. source-port number Enter the keywords source-port then the source port number. The range is from 1 to 65536. The default is None.
Example • Load-balance is configured for MAC • Load-balance is configured for IP 4-tuple/2-tuple • A non-IP payload is going out of Layer 2 LAG interface that is a member of VLAN with an IP address Dell#show port-channel-flow outgoing-port-channel 1 incoming-interface te 3/3 source-mac 00:00:50:00:00:00 destination-mac 00:00:a0:00:00:00 Egress Port for port-channel 1, for the given flow, is Te 13/2 Enhanced Validation of Interface Ranges This functionality is supported on the S6000 platform.
Related Commands Version Description 9.3(0.1) Introduced on the S4810, S4820T, S6000, and Z9000. 8.3.11.1 Introduced on the Z9000 8.2.1.0 Increased number of VLANs on ExaScale to 4094 (was 2094) 8.1.1.0 Introduced on E-Series ExaScale 7.6.1.0 Support added for S-Series 7.5.1.0 Introduced on C-Series ip ftp source interface Configuring source interface for ftp communications.
23 IPv4 Routing The basic IPv4 commands are supported by Dell Networking operating system on the S6000 platform. arp To associate an IP address with a MAC address in the switch, use address resolution protocol (ARP). S6000 Syntax arp [vrf vrf-name] ip-address mac-address interface To remove an ARP address, use the no arp ip-address command. Parameters vrf vrf-name Enter a VRF name to configure an ARP entry for that VRF.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.0 Introduced on the E-Series. You cannot use Class D or Class E IP addresses or zero IP address (0.0.0.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.8.0 Introduced on the S4810. Usage Information This timer is an exponential backoff timer. Over the specified period, the time between ARP requests increases. This behavior reduces the potential for the system to slow down while waiting for a multitude of ARP responses. Related Commands show arp retries — displays the configured number of ARP retries.
arp max-entries Enables you to configure the maximum number of ARP entries per VRF that are allowed for IPv4.. Syntax Parameters arp max-entries [vrf vrf-name] max-number vrf vrf-name Enter the name of a specific VRF for which you want to configure maximum number of ARP entries that IPv4 allows. max-number Enter the maximum number of ARP entries that a VRF RTM can hold. The range is from 0 to 65535. Defaults Not configured.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced. Usage Information Retries are 20 seconds apart. Related Commands show arp retries — displays the configured number of ARP retries. arp timeout Set the time interval for an ARP entry to remain in the ARP cache. S6000 Syntax arp timeout minutes Parameters minutes Enter the number of minutes.
clear arp-cache Clear the dynamic ARP entries from a specific interface or optionally delete (no-refresh) ARP entries from the content addressable memory (CAM). S6000 Syntax Parameters clear arp-cache [vrf vrf-name | interface | ip ip-address] [no-refresh] vrf vrf-name (OPTIONAL) Enter the keyword vrf and then the name of the VRF to clear the ARP cache corresponding to that VRF.
Version Description 8.2.1.0 Added support for 4094 VLANs on the E-Series ExaScale (the prior limit was 2094). 8.1.1.0 Introduced on the E-Series ExaScale. 7.9.1.0 Introduced VRF on the E-Series. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series. clear host Remove one or all dynamically learned host table entries. S6000 Syntax clear host name Parameters name Enter the name of the host to delete.
Parameters unit-number Enter the number of the stack unit. vrf vrf-name Enter the keyword vrf followed by the name of the VRF to clear all FIB entries corresponding to that VRF. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.9.1.0 Introduced VRF on the E-Series. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Added support for 4094 VLANs on the E-Series ExaScale (the prior limit was 2094). 8.1.1.0 Introduced on the E-Series ExaScale. 7.
Version Description 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.4.10 Introduced on the E-Series. Example Dell#debug ip dhcp 00:12:21 : %RELAY-I-PACKET: BOOTP REQUEST (Unicast) received at interface 113.3.3.17 BOOTP Request, hops = 0, XID = 0xbf05140f, secs = 0, hwaddr = 00:60:CF:20:7B:8C, giaddr = 0.0.0.0 00:12:21 : %RELAY-I-BOOTREQUEST: Forwarded BOOTREQUEST for 00:60:CF:20:7B: 8C to 14.
debug ip icmp View information on the internal control message protocol (ICMP). S6000 Syntax debug ip icmp [interface] [count value] To disable debugging, use the no debug ip icmp command. Parameters interface count value (OPTIONAL) Enter the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
ICMP: ICMP: ICMP: ICMP: ICMP: ICMP: Usage Information src 40.40.40.40, dst 40.40.40.40, echo reply echo request sent to dst 40.40.40.40 echo request rcvd from src 40.40.40.40 src 40.40.40.40, dst 40.40.40.40, echo reply src 40.40.40.40, dst 40.40.40.40, echo reply echo request sent to dst 40.40.40.40 To stop packets from flooding the user terminal when debugging is turned on, use the count option. debug ip packet View a log of IP packets sent and received.
Usage Information Example 660 Version Description 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Added support for 4094 VLANs on the E-Series ExaScale (the prior limit was 2094). 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Added the access-group option. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.3.1.0 Added the count option.
IP: s=40.40.40.40 (local), d=224.0.0.6 (Gi 4/11), len 28, sending broad/ multicast proto=2 IP: s=0.0.0.0, d=30.30.30.30, len 100, unroutable ICMP type=8, code=0 IP: s=0.0.0.0, d=30.30.30.30, len 100, unroutable ICMP type=8, code=0 Usage Information To stop packets from flooding the user terminal when debugging is turned on, use the count option. The access-group option supports only the equal to (eq) operator in TCP ACL rules.
Defaults Not configured. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Version Description 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. ip domain-list Configure names to complete unqualified host names. S6000 Syntax ip domain-list name To remove the name, use the no ip domain-list name command. Parameters name Enter a domain name to be used to complete unqualified names (that is, incomplete domain names that cannot be resolved). Defaults Disabled.
• specify a domain name server with the ip name-server command • enable DNS with the ip domain-lookup command To view current bindings, use the show hosts command. To view a DNS-related configuration, use the show running-config resolve command. Related Commands ip domain-name — specifies a DNS server. ip domain-lookup To address resolution (that is, DNS), enable dynamic host-name. S6000 Syntax ip domain-lookup To disable DNS lookup, use the no ip domain-lookup command. Defaults Disabled.
ip domain-name Configure one domain name for the switch. S6000 Syntax ip domain-name name To remove the domain name, use the no ip domain-name command. Parameters name Enter one domain name to be used to complete unqualified names (that is, incomplete domain names that cannot be resolved). Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific.
ip helper-address Specify the address of a DHCP server so that DHCP broadcast messages can be forwarded when the DHCP server is not on the same subnet as the client. S6000 Syntax ip helper-address ip-address To remove a DHCP server address, use the no ip helper-address command. Parameters ip-address Enter an IP address in dotted decimal format (A.B.C.D). Defaults Not configured. Command Modes INTERFACE Command History This guide is platform-specific.
ip helper-address hop-count disable Disable the hop-count increment for the DHCP relay agent. S6000 Syntax ip helper-address hop-count disable To re-enable the hop-count increment, use the no ip helper-address hop-count disable command. Defaults Enabled; the hops field in the DHCP message header is incremented by default. Command Modes CONFIGURATION Command History This guide is platform-specific.
To remove an IP host, use the no ip host name [ip-address] command. Parameters name Enter a text string to associate with one IP address. ip address Enter an IP address, in dotted decimal format, to be mapped to the name. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Defaults Not configured. Command Modes CONFIGURATION Command History Usage Information • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383. • For a port channel interface, enter the keywords port-channel then a number. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.
NOTE: When you configure the capability to enable the loopback IP address to be sent for easy debugging and diagnosis (IP addresses of the devices for which the ICMP source interface is configured), the source IP address of the outgoing ICMP error message is modified, although the packets are not sent out using the configured interface.
ip max-frag-count Set the maximum number of fragments allowed in one packet for packet re-assembly. S6000 Syntax ip max-frag-count count To place no limit on the number of fragments allowed, use the no ip max-frag-count command. Parameters count Enter a number for the number of fragments allowed for re-assembly. The range is from 2 to 256. Defaults No limit is set on number of fragments allowed. Command Modes CONFIGURATION Command History This guide is platform-specific.
ipv4-address2... ipv4-address6 (OPTIONAL) Enter up five more IPv4 addresses, in dotted decimal format, of name servers to be used. Separate the addresses with a space. Defaults No name servers are configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. show ip interface — displays the interface routing status and configuration. ip route Assign a static route to the switch.
• For a port channel interface, enter the keywords port-channel then a number. • For a Null interface, enter the keyword null then the Null interface number. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. • For a tunnel interface, enter the keyword tunnel then the tunnel interface number. The range is from 1 to 16383.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 8.2.1.0 Added support for 4094 VLANs on the E-Series ExaScale (the prior limit was 2094). 8.1.1.0 Introduced on the E-Series ExaScale. 7.9.1.0 Introduced VRF on the E-Series. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. Using the following example of a static route: ip route 33.33.33.0 /24 tengigabitethernet 1/1 172.31.5.
ip source-route Enable Dell Networking OS to forward IP packets with source route information in the header. S6000 Syntax ip source-route To drop packets with source route information, use the no ip route-source command. Defaults Enabled. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Usage Information Version Description 9.3(0.0) Introduced on the S4810, S4820T, S6000, and Z9000 platforms. You can configure the amount of time for which the device must wait before it attempts to establish a TCP connection. Using this capability, you can limit the wait times for TCP connection requests.
Command History Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.1) Introduced on the S6000. Usage Information A warning message is displayed when you enter this command stating that this setting takes effect for existing routes only when IPv4 route prefixes are cleared from the routing table (RTM). To disable this functionality, use no ipv4 unicast-host-route command.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series.
tcp-udp enable Enter the keywords to distribute traffic based on the following: • ingress-port enable enable — Takes the TCP/UDP source and destination ports into consideration when doing hash computations. This option is enabled by default. Enter the keywords to distribute traffic based on the following: • enable — Takes the source port into consideration when doing hash computations. This option is disabled by default.
Parameters {{ip-selection| ipv6selection [source-ip | source-ipv6 | source-port-id | source-module-id | dest-ip | dest-ipv6 | dest-port-id | destmodule-id | protocol | vlan | L4-sourceport | L4-destport ] mac [source-mac | source-port-id | source-module-id | dest-mac | destport-id | destmodule-id | vlan | ethertype | sourcedest-mac ] tunnel [ipv4-overipv4 | ipv4-overgre-ipv4 | mac-inmac]} To use IPv4 key fields in hash computation, enter the keyword ip-selection then one of the parameters.
Version Description 9.0.0.0 Added support for IPv6. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. management route Configure a static route that points to the Management interface or a forwarding router.
Version Description 9.7(0.0) Added support for forty gigabit, vlan, and tengigabit ethernet interfaces. Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000 and added support for IPv6. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series.
• For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. ip ip-address mask (OPTIONAL) Enter the keyword ip then an IP address in the dotted decimal format. Enter the optional IP address mask in the slash prefix format (/ x).
Usage Information The following example shows two VLANs that are associated with a private VLAN (PVLAN) (refer to Private VLAN (PVLAN)). If you have entered the clear arp-cache command to remove a large number of ARP entries and the command is still being processed in the background, an error message display if you attempt to enter the show arp command: Clear arp in-progress. Please try after sometime! The following describes the show arp command shown in the following example.
Description Static Entries Lists the total number of configured or static ARP entries. Dynamic Entries Lists the total number of learned or dynamic ARP entries. CPU Lists which CPU the entries are stored on. Example (Summary) #show arp summary TotalEntries Static Entries Dynamic Entries CPU ---------------------------------------------83 0 83 CP Dell Related Commands ip local-proxy-arp — enables/disables Layer 3 communication in secondary VLANs.
show hosts View the host table and DNS configuration. S6000 Syntax Command Modes Command History show hosts • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.
Field Description • Example ?? — the entry is suspect. TTL Displays the amount of time until the entry ages out of the cache. For dynamically learned entries only. Type Displays IP as the type of entry. Address Displays the IP addresses assigned to the host.
• summary Command Modes Command History • EXEC • EXEC Privilege Enter the keyword group-index then the index number to show ECMP membership per gro The range is from 0 to 1022. (OPTIONAL) Enter the keyword summary to view a table listing route prefixes and the total numb routes which can be entered in to CAM. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Example (ECMPGroup) Dell#show ip cam stack-unit 3 po 0 ecmp-group detail Example (MemberInfo) Dell#show ip cam stack-unit 3 po 0 ecmp-group member-info detail Destination EC C VId Mac-Addr Port ECMP Grou -----------------------------------------------------------------------------------1.1.1.2/32 0 0 1000 00:01:00:00:00:02 Te 3/42 2.1.1.2/32 0 0 20 00:03:00:00:00:02 Po 10 2.1.1.1/32 0 1 0 00:00:00:00:00:00 CP 1.1.1.1/32 0 1 0 00:00:00:00:00:00 CP 2.1.1.0/24 0 1 0 00:00:00:00:00:00 CP 1.1.1.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Added support for up to seven stack members. 7.6.1.0 Introduced on the S-Series. The following describes the show ip fib stack-unit command shown in the following example. Field Description Destination Lists the destination IP address.
Related Commands clear ip fib stack-unit — clear FIB entries on a specified stack-unit. ip ecmp weighted— enables weighted ECMP calculations. show ip flow Show how a Layer 3 packet is forwarded when it arrives at a particular interface. S6000 Syntax show ip flow interface interface {source-ip address destination-ip address} {protocol number [tcp | udp]} {src-port number destination-port number} Parameters interface interface Enter the keyword interface then one of the following interface keywords.
Usage Information Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. This command provides egress port information for a given IP flow. This information is useful in identifying which interface the packet follows in the case of Port-channel and Equal Cost Multi Paths. Use this command for routed packed only. For switched packets, use the show port-channel-flow command.
Command Modes Command History brief (OPTIONAL) Enter the keyword brief to view a brief summary of the interfaces and whether an IP address is assigned. configured (OPTIONAL) Enter the keyword configured to display the physical interfaces with non-default configurations only. • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Example Dell#show ip int te 1/1 TenGigabitEthernet 1/1 is down, line protocol is down Internet address is not set IP MTU is 1500 bytes Inbound access list is not set Proxy ARP is enabled Split Horizon is enabled Poison Reverse is disabled ICMP redirects are not sent ICMP unreachables are not sent Dell# Usage Information Example (Brief) The following describes the show ip interface brief command shown in the following example.
Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.4.1.0 Introduced on the C- and E-Series. 8.3.7.0 Introduced on the S4810.
Example Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. Dell#show ip protocols Routing Protocol is "bgp 1" Cluster Id is set to 20.20.20.3 Router Id is set to 20.20.20.
Command Modes Command History • If you enter isis, you can include the ISIS routing-tag. • If you enter ospf, you can include the OSPF process-id. process-id (OPTIONAL) Specify that only OSPF routes with a certain process ID must be displayed. routing-tag (OPTIONAL) Specify that only ISIS routes with a certain routing tag must be displayed. connected (OPTIONAL) Enter the keyword connected to view only the directly connected routes.
Field Description • B = BGP • IN = internal BGP • EX = external BGP • LO = Locally Originated • O = OSPF • IA = OSPF inter area • N1 = OSPF NSSA external type 1 • N2 = OSPF NSSA external type 2 • E1 = OSPF external type 1 • E2 = OSPF external type 2 • i = IS-IS • L1 = IS-IS level-1 • L2 = IS-IS level-2 • IA = IS-IS inter-area • * = candidate default • > = non-active route • + = summary routes Destination Identifies the route’s destination IP address Gateway Identifies w
Example (Summary) Dell#show ip route summary Route Source Active Routes Non-active Routes connected 2 0 static 1 0 Total 3 0 Total 3 active route(s) using 612 bytes R1_E600i>show ip route static ? | Pipe through a command R1_E600i>show ip route static Destination Gateway Dist/Metric Last Change ----------- ------- ----------- ----------*S 0.0.0.0/0 via 10.10.91.
* 6.6.6.2, via TenGigabitEthernet 1/16 weight 200 Dell(conf)# Example (With Weighted ECMP Disabled) Dell(conf)#ip route 1.1.1.0/24 6.6.6.2 weight 100 Dell(conf)#ip route 1.1.1.0/24 6.6.6.
The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series.
Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
show ip traffic View IP, ICMP, UDP, TCP and ARP traffic statistics. S6000 Syntax show ip traffic [all | cp | rp1 | rp2] NOTE: These options are supported only on the E-Series. Parameters all (OPTIONAL) Enter the keyword all to view statistics from all processors. If you do not enter a keyword, you also view all statistics from all processors. cp (OPTIONAL) Enter the keyword cp to view only statistics from the Control Processor.
Keyword Definition • route not found for unicast/multicast; ingress interfaces do not belong to the destination multicast group • destination IP address belongs to reserved prefixes; the host/network is unreachable bad options... Unrecognized IP option on a received packet. Frags: IP fragments received. ... reassembled Number of IP fragments that were reassembled. ... timeouts Number of times a timer expired on a reassembled queue. ... too big Number of invalid IP fragments received. ...
0 parameter, 0 timestamp, 0 info request, 0 other Sent: 0 redirects, 0 unreachable, 0 echo, 0 echo reply 0 mask requests, 0 mask replies, 0 quench, 0 timestamp 0 info reply, 0 time exceeded, 0 parameter problem UDP statistics: Rcvd: 0 total, 0 checksum errors, 0 no port 0 short packets, 0 bad length, 0 no port broadcasts, 0 socket full Sent: 0 total, 0 forwarded broadcasts TCP statistics: Rcvd: 23829 total, 0 checksum errors, 0 no port Sent: 16048 total ARP statistics: Rcvd: 156 requests, 11 replies Sent: 2
Field Description • 0 checksum error... Example no port = number of packets received with no designated port Displays the number of packets received with the following: • checksum errors • bad offset to data • too short 329 packets... Displays the number of packets and bytes received in sequence. 17 dup... Displays the number of duplicate packets and bytes received. 0 partially... Displays the number of partially duplicated packets and bytes received. 7 out-of-order...
0 checksum error, 0 bad offset, 0 too short 329 packets (1263 bytes) in sequence 17 dup packets (6 bytes) 0 partially dup packets (0 bytes) 7 out-of-order packets (0 bytes) 0 packets ( 0 bytes) with data after window 0 packets after close 0 window probe packets, 41 window update packets 41 dup ack packets, 0 ack packets with unsend data 10184 ack packets (12439508 bytes) Sent: 12007 Total, 0 urgent packets 25 control packets (including 24 retransmitted) 11603 data packets (12439677 bytes) 24 data packets (7
24 IPv6 Basics IPv6 basic commands are supported on the Dell Networking OS. NOTE: For information about the Dell Networking operating software version and platform that supports IPv6 in each software feature, refer to the IPv6 Addressing chapter of the Dell Networking OS Configuration Guide. cam-ipv6 extended-prefix Enable LPM partitioning to support IPv6 /65 to /128 route prefixes to be stored in Partition 1.
Parameters vrf vrf-name (Optional) Enter the keyword vrf followed by the name of the VRF to clear the IPv6 routes corresponding to that VRF. * Enter the * to clear (refresh) all routes from the IPv6 routing table. ipv6-address prefixlength Enter the IPv6 address in the x:x:x:x::x format then the prefix length in the /x format. The range is from /0 to /128. NOTE: The :: notation specifies successive hexadecimal fields of zeros.
warning-only When the warning-only option is used, a syslog message will be thrown when maximum number of dynamic IPv6 routes reaches the limit. Additional dynamic IPv6 routes will still be allowed. Defaults No limit is set on the maximum number of dynamic IPv6 routes for a VRF. Command Modes CONFIGURATION-VRF Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OSCommand Line Reference Guide.
ipv6 unicast-host-route Enable programming of IPv6 /128 route prefixes in L3 host table. S6000 Syntax [no] ipv6 unicast-host-route Defaults Enabled by default. By default, all the IPv6/128 route prefixes are installed only in L3 host table. Command Modes CONFIGURATION Command History Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.1) Introduced on the S6000. Usage Information You can use this command to enable programming of /128 route prefixes in L3 host table or in LPM table.
Command Modes Command History INTERFACE CONFIG Version Description 9.7(0.0) Introduced on the S6000–ON. 9.5(0.0) Introduced on the Z9000, S6000, S4810, S4820T, and MXL.. Usage Information Use this command to add, edit, or delete an IPv6 RDNSS address and lifetime value. You can configure up to four IPv6 RDNSS addresses. You must specify a lifetime using the lifetime or infinite parameter. Example Dell(conf-if-te-1/1)#ipv6 nd dns-server 1000::1 1 ipv6 route Establish a static IPv6 route.
Configure the IPv6 route using a next-hop IPv6 address in order for the ping command to detect the destination address. ipv6-address (OPTIONAL) Enter the forwarding router IPv6 address in the x:x:x:x::x format. NOTE: The :: notation specifies successive hexadecimal fields of zeros. distance (OPTIONAL) Enter a number as the metric distance assigned to the route. The range is from 1 to 255. tag value (OPTIONAL) Enter the keyword tag then a tag value number. The range is from 1 to 4294967295.
You can specify a weight for an IPv4 or IPv6 static route. If the weight value of a path is 0, then that path is not used for forwarding when weighted ECMP is in effect. Also, if a path corresponding to a static route (destination) has a non-zero weight assigned to it and other paths do not have any weight configured, then regular ECMP is used for forwarding. You can specify the weight value only to destination address and not on the egress port.
summary Defaults Command Modes Command History (OPTIONAL) View a brief list of the configured IPv6 routes. none • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Added support for VRF. Introduced on S6000–ON 9.0.0.0 Introduced on the Z9000.
Field Description • Example (S-Series) + = summary routes Destination Identifies the route’s destination IPv6 address. Gateway Identifies whether the route is directly connected and on which interface the route is configured. Dist/Metric Identifies if the route has a specified distance or metric. Last Change Identifies when the route was last changed or configured.
Total 4 active route(s) using 928 bytes Dell# IPv6 Basics 719
25 IPv6 Access Control Lists (IPv6 ACLs) IPv6 ACLs and IPv6 Route Map commands are supported on Dell Networking platform. NOTE: For IPv4 ACL commands, refer to the Access Control Lists (ACL) chapter. Important Points to Remember • Certain platforms require manual CAM usage space allotment. For more information, refer to the cam-acl command. • Egress IPv6 ACL and IPv6 ACL on the Loopback interface is not supported. • Reference to an empty ACL permits any traffic.
Example Version Description 8.3.7.0 Introduced on the S4810. 8.4.2.1 Introduced on the S-Series. 8.4.2.0 Introduced on the E-Series TeraScale. 7.8.1.0 Introduced on the C-Series. Dell#show cam-acl-egress -- Chassis Egress Cam ACL -Current Settings(in block sizes) L2Acl : 1 Ipv4Acl : 1 Ipv6Acl : 2 -- Stack unit 0 -Current Settings(in block sizes) L2Acl : 1 Ipv4Acl : 1 Ipv6Acl : 2 Dell#show cam-acl Related Commands cam-acl — configures CAM profiles to support IPv6 ACLs.
Example Version Description 7.8.1.0 Introduced on the C-Series.
L2Qos : 3 Dell#show cam-acl Related Commands cam-acl — configures CAM profiles to support IPv6 ACLs. permit icmp To allow all or specific internet control message protocol (ICMP) messages, configure a filter. S6000 Syntax permit icmp {source address mask | any | host ipv6-address} {destination address | any | host ipv6-address} [count [byte]] To remove this filter, you have two choices: • Use the no seq sequence-number command if you know the filter’s sequence number.
To remove this filter, you have two choices: Parameters • Use the no seq sequence-number command syntax if you know the filter’s sequence number • Use the no permit {ipv6-protocol-number | icmp | ipv6 | tcp | udp} command ip-protocol-number Enter an IPv6 protocol number. The range is from 0 to 255. icmp Enter the keyword icmp to filter internet Control Message Protocol version 6. ipv6 Enter the keyword ipv6 to filter any internet Protocol version 6.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.10.0 Introduced on the S4810. ipv6 access-list Configure an access list based on IPv6 addresses or protocols. S6000 Syntax ipv6 access-list access-list-name cpu-qos {permit | deny} ospfv3 To delete an access list, use the no ipv6 access-list access-list-name command. Parameters access-list-name Enter the access list name as a string, up to 140 characters.
Usage Information Version Description 7.4.1.0 Introduced on the E-Series TeraScale. The number of entries allowed per ACL is hardware-dependent. For detailed specification on entries allowed per ACL, refer to your line card documentation. You can create an IPv6 ACL for control-plane traffic policing for OSPFv3, in addition to the CoPP support for VRRP, BGP, and ICMP. cam-acl-egress Allocate space for IPv6 egress ACLs.
Example Dell# Dell#configure Dell(conf)#cam-acl-egress ? default Reset Egress CAM ACL entries to default setting l2acl Set L2-ACL entries Dell(conf)#cam-acl-egress l2acl ? <1-4> Number of FP blocks for l2acl Dell(conf)#cam-acl-egress l2acl 1 ? ipv4acl Set IPV4-ACL entries Dell(conf)#cam-acl-egress l2acl 1 ipv4acl 1 ? ipv6acl Set IPV6-ACL entries Dell(conf)#cam-acl-egress l2acl 1 ipv4acl 1 ipv6acl ? <0-4> Number of FP blocks for IPV6 (multiples of 2) Dell(conf)#cam-acl-egress l2acl 1 ipv4acl 1 ipv6acl 2 ca
Usage Information Version Description 8.4.2.0 Introduced on the E-Series TeraScale. 8.2.1.0 Introduced on the S-Series. 7.8.1.0 Introduced on the C-Series. For the new settings to take effect, save the new CAM settings to the startup-config (write-mem or copy run start), then reload the system. The total amount of space allowed is 16 FP blocks. System flow requires three blocks and these blocks cannot be reallocated. When configuring space for IPv6 ACLs, the total number of Blocks must equal 13.
26 Intermediate System to Intermediate System (ISIS) The intermediate system to intermediate system (IS-IS) protocol for IPv4 and IPv6 is supported on the S6000 platform. IS-IS is an interior gateway protocol that uses a shortest-path-first algorithm. IS-IS facilitates the communication between open systems, supporting routers passing both IP and OSI traffic. A router is considered an intermediate system. Networks are partitioned into manageable routing domains, called areas.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 7.5.1.0 Introduced on the E-Series. To perform protocol-support consistency checks on hello packets, use this command. The adjacency-check is enabled by default. If a BFD session goes down indicating that IPv4 or IPv6 connectivity to its neighbor is lost, it does not imply that the adjacency is lost altogether. The hello adjacency runs over Layer 2, and does not require IP connectivity.
Usage Information Version Description 7.5.1.0 Added IPv6 ISIS support. 6.3.1.0 Version 6.3.1.0 Introduced You cannot disable leaking from Level 1 to Level 2. Also, you cannot enable leaking from Level 2 to Level 1. However, you can regulate the rate flow from one level to another using an IP Prefix list. If you do not configure the IP Prefix list, all Level 1 routes are leaked. You can find more information in IETF RFC 2966, Domain-wide Prefix Distribution with Two-Level IS-IS.
• isis password — allows you to configure an authentication password for an interface. clear config Clear IS-IS configurations that display under the router isis heading of the show running-config command output. Syntax clear config Command Modes ROUTER ISIS Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000.
debug isis Enable debugging for all IS-IS operations. Syntax debug isis To disable debugging of IS-IS, use the no debug isis command. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
• For a port channel interface, enter the keywords port-channel then a number. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Added support for VRF.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000-ON. 9.2(0.2) Introduced on the Z9000. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 6.3.1.0 Introduced.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 6.3.1.0 Introduced. debug isis spf-triggers Enable debugging on the events that triggered IS-IS shortest path first (SPF) events for debugging purposes. S6000 Syntax debug isis [vrf vrf-name] spf-triggers To turn off debugging, use the no debug isis [vrf vrf-name] spf-triggers command.
To turn off debugging, use the no debug isis update-packets [interface] command. Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to enable the debugging information on IS-IS. This information contains updates from neighbors tied to the VRF that you specify. This command displays the debugging details of the received LSPs from the neighbors.
route-map mapname Defaults Command Modes Command History (OPTIONAL) A default route the routing process generates if the route map is satisfied. Not configured. • ROUTER ISIS (for IPv4) • CONFIGURATION-ROUTER-ISIS-ADDRESS-FAMILY-IPV6 (for IPv6) This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Command Modes Command History Related Commands ROUTER ISIS Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. pre-7.7.1.0 Introduced. router isis — Enter ROUTER mode on the switch. distance Define the administrative distance for learned routes.
Usage Information Version Description 6.3.1.0 Introduced. The administrative distance indicates the trust value of incoming packets. A low administrative distance indicates a high trust rate. A high value indicates a lower trust rate. For example, a weight of 255 is interpreted that the routing information source is not trustworthy and should be ignored. distribute-list in Filter network prefixes received in updates.
Related Commands Version Description 6.3.1.0 Introduced. • distribute-list out — suppresses networks from being advertised in updates. • redistribute — redistributes routes from one routing domain to another routing domain. distribute-list out Suppress network prefixes from being advertised in outbound updates.
Usage Information Related Commands You can assign a name to a routing process so a prefix list IS applied to only the routes derived from the specified routing process. • distribute-list in — filters the networks received in updates. • redistribute — redistributes routes from one routing domain to another routing domain. distribute-list redistributed-override Suppress flapping of routes when the same route is redistributed into IS-IS from multiple routers in the network.
encryption-type (OPTIONAL) Enter 7 to encrypt the password using DES. password Enter an alphanumeric string up to 16 characters long. If you do not specify an encryption type or hmac-md5 keywords, the password is processed as plain text which provides limited security. Defaults No default password. Command Modes ROUTER ISIS Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 6.3.1.0 Introduced on the E-Series. Every graceful restart enabled router’s HELLO PDUs includes a restart TLV. This restart enables (re)starting as well as the existing ISIS peers to detect the GR capability of the routers on the connected network.
Version Description 8.3.1.0 Introduced on the E-Series. graceful-restart restart-wait Enable the graceful restart maximum wait time before a restarting peer comes up. Syntax NOTE: Set the t3 timer to adjacency on the restarting router when implementing this command. graceful-restart restart-wait seconds To return to the default, use the no graceful-restart restart-wait command. Parameters seconds Enter the graceful restart time in seconds. The range is from 5 to 300 seconds.
Parameters interval Enter the keyword interval to set the wait time. The range is from 5 to 120 seconds. The default is 5 seconds. retry-times Enter the keywords retry-times to set the number of times the request interval is extended until a CSNP is received from the helping router. The range is from 1 to 10 attempts. The default is 1. Defaults Refer to Parameters. Command Modes ROUTER ISIS Command History This guide is platform-specific.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.3.1.0 Introduced on the E-Series. graceful-restart t3 Configure the overall wait time before graceful restart completes. Syntax graceful-restart t3 {adjacency | manual} seconds To return to the default, use the no graceful-restart t3 command.
Set the t3 timer to adjacency on the restarting router when implementing this command. The restarting router gets the remaining time value from its peer and adjusts its T3 value so only when you have configured graceful-restart t3 adjacency. Related Commands graceful-restart restart-wait — enables the graceful restart maximum wait time before a restarting peer comes up.
hostname dynamic Enables dynamic learning of hostnames from routers in the domain and allows the routers to advertise the hostname in LSPs. Syntax hostname dynamic To disable this command, use the no hostname dynamic command. Defaults Enabled. Command Modes ROUTER ISIS Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. IS-IS normally purges LSPs with an incorrect data link checksum causing the LSP source to regenerate the message. A cycle of purging and regenerating LSPs can occur when a network link continues to deliver accurate LSPs even though there is a link causing data corruption. This process could cause disruption to your system operation.
• router isis — enables the IS-IS routing protocol. ipv6 router isis Enable the IPv6 IS-IS routing protocol and specify an IPv6 IS-IS process. Syntax ipv6 router isis [tag] To disable IS-IS routing, use the no router isis [tag] command. Parameters tag (OPTIONAL) This parameter is a unique name for a routing process. A null tag is assumed if the tag option is not specified. The tag name must be unique for all IP router processes for a given router. Defaults Not configured.
isis circuit-type Configure the adjacency type on interfaces. Syntax isis circuit-type {level-1 | level-1-2 | level-2-only} To return to the default values, use the no isis circuit-type command. Parameters level-1 You can form a Level 1 adjacency if there is at least one common area address between this system and neighbors. You cannot form Level 2 adjacencies on this interface.
Parameters seconds Interval of transmission time between CSNPs on multi-access networks for the designated intermediate system. The range is from 0 to 65535. The default is 10. level-1 (OPTIONAL) Independently configures the interval of time between transmission of CSNPs for Level 1. level-2 (OPTIONAL) Independently configures the interval of time between transmission of CSNPs for Level 2.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. Usage Information The holdtime (the product of the hello-multiplier multiplied by the hello-interval) determines how long a neighbor waits for a hello packet before declaring the neighbor is down so routes can be recalculated. Related Commands isis hello-interval — specifies the length of time between hello packets.
To return to the default values, use the no ipv6 isis metric [default-metric] [level-1 | level-2] command. Parameters default-metric Metric assigned to the link and used to calculate the cost from each other router via the links in the network to other destinations. You can configure this metric for Level 1 or Level 2 routing. The range is from 0 to 16777215. The default is 10.
If metric value is configured to more than 63, system throughs the following warning:Warning: for metrics greater than 63, 'metric-style wide' should be configured on level-1-2, or it will be capped at 63. If the metric style is WIDE, the metric values that are greater than 63 are only effective. level-1 (OPTIONAL) Enter the keywords level-1 to configure the shortest path first (SPF) calculation for Level 1 (intra-area) routing. This setting is the default.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. isis password Configure an authentication password for an interface. Syntax isis password [hmac-md5] password [level-1 | level-2] To delete a password, use the no isis password [password] [level-1 | level-2] command. Parameters encryption-type (OPTIONAL) Enter 7 to encrypt the password using DES.
You can assign different passwords for different routing levels by using the keywords level-1 and level-2. The no form of this command disables the password for Level 1 or Level 2 routing, using the respective keywords level-1 or level-2. This password provides limited security as it is processed as plain text. isis priority Set the priority of the designated router you select.
is-type Configure IS-IS operating level for a router. Syntax is-type {level-1 | level-1-2 | level-2-only} To return to the default values, use the no is-type command. Parameters level-1 Allows a router to act as a Level 1 router. level-1-2 Allows a router to act as both a Level 1 and Level 2 router. This setting is the default. level-2-only Allows a router to act as a Level 2 router. Defaults level-1-2 Command Modes ROUTER ISIS Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 7.5.1.0 Added support for LSP Throttling Enhancement. LSP throttling slows down the frequency at which LSPs are generated during network instability.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 7.5.1.0 Added support for LSP Throttling Enhancement. The link MTU and the LSP MTU size must be the same. Because each device can generate a maximum of 255 LSPs, consider carefully whether you use the lspmtu command. lsp-refresh-interval Set the link state PDU (LSP) refresh interval. LSPs must be refreshed before they expire.
The refresh interval must be less than the LSP lifetime specified with the max-lsp-lifetime command. A low value reduces the amount of time that undetected link state database corruption can persist at the cost of increased link utilization. A higher value reduces the link utilization the flooding of refreshed packets causes. Related Commands max-lsp-lifetime — sets the maximum interval that LSPs persist without being refreshed. max-area-addresses Configure manual area addresses.
Parameters seconds The maximum lifetime of LSP in seconds. This value must be greater than the lsp-refresh-interval command. The higher the value the longer the LSPs are kept. The range is from 1 to 65535. The default is 1200. Defaults 1200 seconds Command Modes ROUTER ISIS Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 7.8.1.0 Added support for multi-topology ISIS. 6.3.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.12.0 Introduced on the S4810. If you enter the metric-style wide command, the Dell Networking OS generates and accepts only new-style TLVs. The router uses less memory and other resources rather than generating both old-style and new-style TLVs. The new-style TLVs have wider metric fields than old-style TLVs.
net To configure an IS-IS network entity title (NET) for a routing process, use this mandatory command. If you did not configure a NET, the IS-IS process does not start. Syntax net network-entity-title To remove a net, use the no net network-entity-title command. Parameters network-entity-title Specify the area address and system ID for an IS-IS routing process. The first 1 to 13 bytes identify the area address. The next 6 bytes identify the system ID.
• For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. Defaults Not configured. Command Modes ROUTER ISIS Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Defaults Command Modes Command History level-2 (OPTIONAL) Routes are independently redistributed into IS-IS as Level 2 routes. This setting is the default. route-map mapname (OPTIONAL) If you do not enter the route-map argument, all routes are redistributed. If a map-name value is not specified, no routes are imported. • metric metric-value = 0 • metric-type= internal; level-2 • ROUTER ISIS (for IPv4) • CONFIGURATION-ROUTER-ISIS-ADDRESS-FAMILY-IPV6 (for IPv6) This guide is platform-specific.
redistribute bgp Redistribute routing information from a BGP process. Syntax redistribute bgp AS number [level-1| level-1-2 | level-2] [metric metricvalue] [metric-type {external| internal}] [route-map map-name] To return to the default values, use the no redistribute bgp command with the appropriate parameters. Parameters AS number Enter a number that corresponds to the autonomous system number. The range is from 1 to 65355.
Version Description 7.5.1.0 Added support for IPv6 ISIS. 6.3.1.0 Introduced. Usage Information BGP to IS-IS redistribution supports “match” options using route maps. You can set the metric value, level, and metric-type of redistributed routes by the redistribution command. You can “set” more advanced options using route maps.
route-map mapname map-name is an identifier for a configured route map. The route map should filter imported routes from the source routing protocol to the current routing protocol. If you do not specify a map-name, all routes are redistributed. If you specify a keyword, but fail to list route map tags, no routes are imported. Defaults Refer to Parameters.
tag (OPTIONAL) This is a unique name for a routing process. A null tag is assumed if the tag option is not specified. The tag name must be unique for all IP router processes for a given router. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
• Command History CONFIGURATION-ROUTER-ISIS-ADDRESS-FAMILY-IPV6 (for IPv6) This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.
Example (RouterIsis) The bold section identifies that Multi-Topology IS-IS is enabled in Transition mode. Dell(conf-router_isis)#show config ! router isis clns host ISIS 49.0000.0001.F100.E120.0013.00 log-adjacency-changes net 49.0000.0001.F100.E120.0013.
system-id Command Modes Command History • EXEC • EXEC Privilege (OPTIONAL) Displays the link-state database for system-id. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Added supported for VRF. Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.
Example Field Description ATT This value represents the Attach bit. This value indicates that the router is a Level 1-2 router and can reach other areas. Level 1-only routers and Level 1-2 routers that have lost connection to other Level 1-2 routers use the Attach bit to find the closest Level 1-2 router. They install a default route to the closest Level 1-2 router. P This value represents the P bit. This bit is always set to zero as Dell Networking does not support area partition repair.
Dell#show isis database detail IS-IS Level-1 Link State Database LSPID LSP Seq Num FTOS.00-00 * 0x00000009 NLPID: 0xCC Area Address: 49.0000.0001 LSP Checksum 0x79D8 LSP Holdtime 941 ATT/P/OL 1/0/0 show isis graceful-restart detail Display detailed IS-IS graceful restart related settings.
====================== Current Mode/State T3 Time left T2 Time left Restart ACK rcv count Restart Req rcv count Suppress Adj rcv count Restart CSNP rcv count Database Sync count : : : : : : : : Normal/RUNNING 0 0 (level-1), 0 0 (level-1), 0 0 (level-1), 0 0 (level-1), 0 0 (level-1), 0 0 (level-1), 0 (level-2) (level-2) (level-2) (level-2) (level-2) (level-2) show isis hostname Display IS-IS host names configured or learned on the switch.
show isis interface Display detailed IS-IS interface status and configuration information. S6000 Syntax show isis [vrf vrf-name] interface [interface] Parameters Command Modes Command History vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to display ISIS interface status information corresponding to that VRF.
LSP Interval: 33 TenGigabitEthernet 1/8 is up, line protocol is up MTU 1497, Encapsulation SAP Routing Protocol: IS-IS Circuit Type: Level-1-2 Interface Index 38371358, Local circuit ID 2 Level-1 Metric: 10, Priority: 64, Circuit ID: systest-3.02 Hello Interval: 10, Hello Multiplier: 3, CSNP Interval: 10 Number of active level-1 adjacencies: 1 Level-2 Metric: 10, Priority: 64, Circuit ID: systest-3.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. Use this command to confirm that the neighbor adjacencies are operating correctly. If you suspect that they are not, you can verify the specified area addresses of the routers by using the show isis neighbors command. The following describes the show isis neighbors command shown in the following example.
Parameters Command Modes Command History vrf vrf-name • EXEC • EXEC Privilege (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to display ISIS routing information corresponding to that VRF. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.
Parameters Command Modes Command History vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to display ISIS traffic interface information corresponding to that VRF. interface (OPTIONAL) Identifies the interface type slot/port as one of the following: • EXEC • EXEC Privilege • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
Example Item Description Level-1/Level-2 LSPs PSNPs (sent/ rcvd) Displays the number of PSNP LPSs sent and received. Level-1/Level-2 DR Elections Displays the number of times designated router elections ran. Level-1/Level-2 SPF Calculations Displays the number of shortest path first calculations. LSP checksum errors received Displays the number of checksum errors LSPs received. LSP authentication failures Displays the number of LSP authentication failures.
Defaults initial_wait_interval seconds (OPTIONAL) Enter the initial wait time, in seconds, before running the first SPF calculations. The range is from 0 to 120 seconds. The default is 5 seconds. second_wait_interv al seconds (OPTIONAL) Enter the wait interval, in seconds, between the first and second SPF calculations. The range is from 0 to 120 seconds. The default is 5 seconds. Refer to Parameters.
27 Link Aggregation Control Protocol (LACP) This chapter contains commands for Dell Networks’s implementation of the link aggregation control protocol (LACP) for creating dynamic link aggregation groups (LAGs) — known as “port-channels” in the Dell Networking operating software. The LACP commands in this chapter are supported by Dell Networking OS on the S6000 platform. NOTE: For static LAG commands, refer to Port Channel Commands in the Interfaces chapter), based on the standards specified in the IEEE 802.
Related Commands Version Description 6.2.1.1 Introduced on the E-Series. show lacp — displays the LACP configuration. debug lacp Debug LACP (configuration, events, and so on). S6000 Syntax debug lacp [config | events | pdu [interface-type [in | out]]] To disable LACP debugging, use the no [config | events | pdu [interface-type [in | out]]] command. Parameters config (OPTIONAL) Enter the keyword config to debug the LACP configuration.
Version Description 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. lacp long-timeout Configure a long timeout period (30 seconds) for an LACP session. S6000 Syntax lacp long-timeout To reset the timeout period to a short timeout (1 second), use the no lacp long-timeout command.
lacp port-priority To influence which ports will be put in Standby mode when there is a hardware limitation that prevents all compatible ports from aggregating, configure the port priority. S6000 Syntax lacp port-priority priority-value To return to the default setting, use the no lacp port-priority priority-value command. Parameters priority-value Enter the port-priority value. The higher the value number, the lower the priority. The range is from 1 to 65535. The default is 32768.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.
show lacp Display the LACP matrix. S6000 Syntax show lacp port-channel-number [sys-id | counters] Parameters Defaults port-channelnumber Enter a port-channel number. The range is from 1 to 128. sys-id (OPTIONAL) Enter the keywords sys-id and the value that identifies a system. counters (OPTIONAL) Enter the keyword counters to display the LACP counters. Without a Port Channel specified, the command clears all Port Channel counters.
Dell# Example (Sys-id) Oper: State BCEGIKNP Key 1 Priority 128 Dell#show lacp 1 sys-id Actor System ID: Priority 32768, Address 0001.e800.a12b Partner System ID: Priority 32768, Address 0001.e801.
28 Layer 2 This chapter describes commands to configure Layer 2 features. This chapter contains the following sections: • MAC Addressing Commands • Virtual LAN (VLAN) Commands • Far-End Failure Detection (FEFD) The VLAN commands are supported on all the S6000 platform. MAC Addressing Commands The following commands are related to configuring, managing, and viewing MAC addresses. mac-address-table aging-time Specify an aging time for MAC addresses to remove from the MAC address table.
Related Commands Version Description 8.3.1.0 On the E-Series, available in INTERFACE VLAN context, reduced the minimum aging time in the INTERFACE VLAN context from 10 seconds to 1 second. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series. mac learning-limit — sets the MAC address learning limits for a selected interface. show mac-address-table aging-time — displays the MAC aging time.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 9.1(0.0) Added support for output range parameter for S4810 and Z9000. 8.3.19.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series. For details about using this command, refer to the “NIC Teaming” section of the Layer 2 chapter in the Dell Networking OS Configuration Guide. mac learning-limit Limit the maximum number of MAC addresses (static + dynamic) learned on a selected interface.
Usage Information Version Description 8.2.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. Added the station-move option. 6.5.1.0 Added support for MAC Learning-Limit on the LAG. This command and its options are supported on physical interfaces, static LAGs, LACP LAGs, and VLANs. If you do not specify the vlan option, the MAC address counters are not VLAN-based.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the S-Series. 7.8.1.
Usage Information If you configure mac-learn-limit and the sticky MAC feature is enabled, dynamically learned MAC addresses are converted to sticky for that port. Any new MAC address that is learned also becomes sticky for that port. Related Commands show mac learning-limit — displays the details of the mac learning-limit. mac learning-limit station-move-violation Specify the actions for a station move violation.
mac learning-limit reset Reset the MAC address learning-limit error-disabled state. S6000 Syntax mac learning-limit reset Defaults none Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Command Modes Command History aging-time Enter the keyword aging-time to display only aging-time information. interface interface (OPTIONAL) Enter the keyword interface then the interface type, slot/port information: • For a port channel interface, enter the keywords port-channel then a number. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
Column Heading Description Type Lists whether the MAC address was manually configured (Static), learned dynamically (Dynamic), or associated with a specific port (Sticky). Interface Displays the interface type and slot/port information. The following abbreviations describe the interface types: State Example Usage Information • gi — Gigabit Ethernet then a slot/port. • po — Port Channel then a number. The range is from 1 to 255 for TeraScale. • te — 10 Gigabit Ethernet then a slot/port.
Static Address (User-defined) Count : 0 Sticky Address Count : 0 Total Synced Mac from Peer(N): 100 Total MAC Addresses in Use: 110 Dell# Related Commands show mac-address-table aging-time — displays MAC aging time. show mac-address-table aging-time Display the aging times assigned to the MAC addresses on the switch.
Parameters Command Modes Command History violate-action (OPTIONAL) Enter the keywords violate-action to display the MAC learning limit violation status. detail (OPTIONAL) Enter the keyword detail to display the MAC learning limit in detail. interface interface (OPTIONAL) Enter the keyword interface with the following keywords and slot/port or number information: • EXEC • EXEC Privilege • For a port channel interface, enter the keywords port-channel then a number. The range is from 1 to 128.
Virtual LAN (VLAN) Commands The following commands configure and monitor virtual LANs (VLANs). VLANs are a virtual interface and use many of the same commands as physical interfaces. You can configure an IP address and Layer 3 protocols on a VLAN called Inter-VLAN routing. FTP, TFTP, ACLs and SNMP are not supported on a VLAN. Occasionally, while sending broadcast traffic over multiple Layer 3 VLANs, the VRRP state of a VLAN interface may continually switch between Master and Backup.
description Add a description about the selected VLAN. S6000 Syntax Parameters description description description Defaults none Command Modes INTERFACE VLAN Command History Related Commands Enter a text string description to identify the VLAN (80 characters maximum). Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
Usage Information The no default vlan disable command is not listed in the running-configuration, but when the default VLAN is disabled, default-vlan disable is listed in the running-configuration. name Assign a name to the VLAN. S6000 Syntax name vlan-name To remove the name from the VLAN, use the no name command. Parameters vlan-name Enter up to 32 characters as the name of the VLAN. Defaults Not configured. Command Modes INTERFACE VLAN Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.1.(0.0) Updated to support OpenFlow. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.
Column Heading Description Example • Po = port channel • Gi = gigabit Ethernet • Te = ten-gigabit Ethernet Dell#show vlan Codes: * - Default VLAN, G - GVRP VLANs, P - Primary, C - Community, I Isolated Q: U - Untagged, T - Tagged, O - Openflow x - Dot1x untagged, X - Dot1x tagged o - OpenFlow untagged, O - OpenFlow tagged G - GVRP tagged, M - Vlan-stack i - Internal untagged, I - Internal tagged, v - VLT untagged, V - VLT tagged NUM Status Description Q Ports * 1 Inactive 2 Active U Po1(Te 13/1) T P
x - Dot1x untagged, X - Dot1x tagged G - GVRP tagged, M - Vlan-stack NUM 42 Dell# Status Description Q Ports Active U Te 13/47 Example (Brief) Dell#show vlan br VLAN Name STG MAC Aging IP Address ---- -----------------------------------1 0 1800 unassigned 2 0 1800 2.2.2.2/24 3 0 1800 3.3.3.
Command Modes INTERFACE VLAN Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.
Defaults Not configured. Command Modes INTERFACE VLAN Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
• For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. Defaults All interfaces in Layer 2 mode are untagged. Command Modes INTERFACE VLAN Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
debug fefd Enable debugging of FEFD. S6000 Syntax debug fefd {events | packets} [interface] To disable debugging of FEFD, use the no debug fefd {events | packets} [interface] command. Parameters events Enter the keyword events to enable debugging of FEFD state changes. packets Enter the keyword packets to enable debugging of FEFD to view information on packets sent and received.
interval Enter the keyword interval, followed by a value to specify the FEFD interval in seconds. Range is from 3 to 300. Default is 15. mode Enter the keyword mode followed by the mode type to specify the FEFD mode. • normal: Change the link state to “unknown” when a far-end failure is detected by the software on that interface. When the interface is placed in an “unknown” state, the software brings down the line protocol.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. Legacy E-Series command. Usage Information Related Commands When you enter no fefd for an interface and fefd-global, FEFD is enabled on the interface because the no fefd command is not retained in the configuration file.
fefd mode Change the FEFD mode on an interface. Syntax fefd mode {normal | aggressive}] To return the FEFD mode to the default of normal, use the no fefd mode command. Parameters normal (OPTIONAL) Enter the keyword normal to change the link state to “unknown” when a far-end failure the software detects on that interface. When the interface is placed in “unknown” state, the software brings down the line protocol.
• For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. Defaults Not configured. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.
Version Description 8.3.7.0 Introduced on the S4810. Legacy E-Series command. Related Commands • fefd — enables far-end failure detection. • fefd-global — enables FEFD globally on the system. fefd-global Enable FEFD globally on the system. S6000 Syntax fefd-global [interval seconds][mode {normal | aggressive}] To disable FEFD globally, use the no fefd-global [mode {normal | aggressive}] command.
Usage Information If you enter only the fefd-global syntax, the mode is normal and the default interval is 15 seconds. If you disable FEFD globally (no fefd-global), the system does not remove the FEFD interface configuration. Related Commands • fefd — enables far-end failure detection. • fefd-global interval — configures an interval between FEFD control packets. • show fefd — shows the FEFD command output. show fefd View FEFD status globally or on a specific interface.
Example Field Description Interval Displays the interval between FEFD packets. State Displays the state of the interface and can be one of the following: • bi-directional (interface is up, connected and hearing neighbor’s echoes). • err-disabled (only found when FEFD mode is aggressive and when the interface has not hearing its neighbor’s echoes for three times the message interval. To reset an interface in this state, use the fefd reset command.) • unknown (only found when FEFD mode is normal.
29 Link Layer Discovery Protocol (LLDP) The link layer discovery protocol (LLDP) advertises connectivity and management from the local station to the adjacent stations on an IEEE 802 LAN. This chapter contains the following sections: • LLPD Commands • LLDP-MED Commands LLDP facilitates multi-vendor interoperability by using standard management tools to discover and make available a physical topology for network management.
Command Modes CONFIGURATION (conf-lldp) and INTERFACE (conf-if-interface-lldp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series. clear lldp counters Clear LLDP transmitting and receiving counters for all physical interfaces or a specific physical interface.
clear lldp neighbors Clear LLDP neighbor information for all interfaces or a specific interface. S6000 Syntax Parameters clear lldp neighbors {interface} interface Defaults none Command Modes EXEC Privilege Command History Enter the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
all (OPTIONAL) Enter the keyword all to display information on all interfaces. events (OPTIONAL) Enter the keyword events to display major events such as timer events. packet (OPTIONAL) Enter the keyword packet to display information regarding packets coming in or going out. brief (OPTIONAL) Enter the keyword brief to display brief packet information. detail (OPTIONAL) Enter the keyword detail to display detailed packet information.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series.
Version Description 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series. mode To receive or transmit, set LLDP. S6000 Syntax mode {tx | rx} To return to the default, use the no mode {tx | rx} command. Parameters tx Enter the keyword tx to set the mode to transmit. rx Enter the keyword rx to set the mode to receive. Defaults Both transmit and receive.
multiplier Set the number of consecutive misses before LLDP declares the interface dead. S6000 Syntax multiplier integer To return to the default, use the no multiplier integer command. Parameters integer Enter the number of consecutive misses before the LLDP declares the interface dead. The range is from 2 to 10. Defaults 4 x hello Command Modes CONFIGURATION (conf-lldp) and INTERFACE (conf-if-interface-lldp) Command History This guide is platform-specific.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series. protocol lldp (Interface) Enter the LLDP protocol in INTERFACE mode.
show lldp neighbors Display LLDP neighbor information for all interfaces or a specified interface. S6000 Syntax Parameters show lldp neighbors [interface] [detail] interface detail (OPTIONAL) Enter the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
show lldp statistics Display the LLDP statistical information. S6000 Syntax show lldp statistics Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.11.
• LLDP-MED Network Connectivity Device — any device that provides access to an IEEE 802 LAN to an LLDP-MED endpoint device, and supports IEEE 802.1AB (LLDP) and TIA-1057 (LLDP-MED). The Dell Networking system is an LLDP-MED network connectivity device.
show lldp neighbors — displays the LLDP neighbors. advertise med guest-voice-signaling To advertise a separate limited voice service for a guest user when the guest voice control packets use a separate network policy than the voice data, configure the system.
advertise med location-identification To advertise a location identifier, configure the system. S6000 Syntax advertise med location-identification {coordinate-based value | civic-based value | ecs-elin value} To return to the default, use the no advertise med location-identification {coordinate-based value | civic-based value | ecs-elin value} command. Parameters coordinate-based value Enter the keywords coordinate-based then the coordinated based location in hexadecimal value of 16 bytes.
advertise med power-via-mdi To advertise the Extended Power via MDI TLV, configure the system. S6000 Syntax advertise med power-via-mdi To return to the default, use the no advertise med power-via-mdi command. Defaults unconfigured. Command Modes CONFIGURATION (conf-lldp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
priority-tagged number Enter the keywords priority-tagged then the Layer 2 priority. The range is from 0 to 7. Defaults unconfigured. Command Modes CONFIGURATION (conf-lldp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series.
Related Commands Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series and E-Series. debug lldp interface — debugs LLDP. show lldp neighbors — displays the LLDP neighbors. advertise med video-signaling To advertise video control packets that use a separate network policy than video data, configure the system.
Related Commands Version Description 7.6.1.0 Introduced on the C-Series and E-Series. debug lldp interface — debugs LLDP. show lldp neighbors — displays the LLDP neighbors. advertise med voice To advertise a dedicated IP telephony handset or other appliances supporting interactive voice services, configure the system.
advertise med voice-signaling To advertise when voice control packets use a separate network policy than voice data, configure the system. S6000 Syntax advertise med voice-signaling {vlan-id layer2_priority DSCP_value} | {priority-tagged number} To return to the default, use the no advertise med voice-signaling {vlan-id layer2_priority DSCP_value} | {priority-tagged number} command. Parameters vlan-id Enter the VLAN ID. The range is from 1 to 4094.
30 Microsoft Network Load Balancing Network Load Balancing (NLB) is a clustering functionality that is implemented by Microsoft on Windows 2000 Server and Windows Server 2003 operating systems. Microsoft NLB clustering allows multiple servers running Microsoft Windows to be represented by one MAC and one IP address to provide transparent failover and load-balancing.
Related Commands clear arp-cache — clears dynamic ARP entries from the ARP table. show arp — displays the ARP table. mac-address-table static (for Multicast MAC Address) For multicast mode of network load balancing (NLB), configure a static multicast MAC address, associate the multicast MAC address with the VLAN used to switch Layer 2 multicast traffic, and add output ports that will receive multicast streams on the VLAN.
Example (Multicast) Version Description 9.3(0.0) Added support for multicast MAC address on the MXL platform. mac-address-table static 01:00:5E:01:00:01 {multicast vlan 2 output—range Te 1/2,Te 1/3} ip vlan-flooding Enable unicast data traffic flooding on VLAN member ports. Syntax ip vlan-flooding To disable, use the no ip vlan-flooding command. Command Modes Command History CONFIGURATION Version 9.3(0.0) Introduced on the S4810, S4820T, S6000, Z9000, and MXL platforms Version Description 9.
31 Multicast Source Discovery Protocol (MSDP) Multicast source discovery protocol (MSDP) connects multiple PIM Sparse-Mode (PIM-SM) domains together. MSDP peers connect using TCP port 639. Peers send keepalives every 60 seconds. A peer connection is reset after 75 seconds if no MSDP packets are received. MSDP connections are parallel with MBGP connections. The Dell Networking operating system supports MSDP commands on the S6000 platform.
clear ip msdp sa-cache Clears the entire source-active cache, the source-active entries of a particular multicast group, rejected, or local source-active entries. S6000 Syntax clear ip msdp sa-cache [group-address | rejected-sa | local] Parameters group-address Enter the group IP address in dotted decimal format (A.B.C.D.).
peer-address Enter the IP address of the MSDP peer. Defaults Without any options, this command clears the entire source-active cache. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Related Commands Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.4.1.0 Introduced show ip msdp sa-cache rejected-sa — displays the rejected SAs in the SA cache. ip msdp default-peer Define a default peer from which to accept all source-active (SA) messages. S6000 Syntax ip msdp default-peer peer address [list name] To remove the default peer, use the no ip msdp default-peer {peer address} list name command.
ip msdp log-adjacency-changes Enable logging of MSDP adjacency changes. S6000 Syntax ip msdp log-adjacency-changes To disable logging, use the no ip msdp log-adjacency-changes command. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 6.2.1.1 Introduced An MSDP mesh group is a mechanism for reducing SA flooding, typically in an intra-domain setting. When some subset of a domain’s MSDP speakers are fully meshed, they can be configured into a mesh-group.
Version Description 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 6.2.1.1 Introduced ip msdp peer Configure an MSDP peer.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 7.5.1.0 Added option for SA upper limit and the description option. 6.2.1.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced Modifications to the ACL do not have an immediate effect on the sa-cache.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the E-Series. ip msdp sa-limit Configure the upper limit of source-active (SA) entries in SA-cache. S6000 Syntax ip msdp sa-limit number To return to the default, use the no ip msdp sa-limit number command. Parameters number Enter the maximum number of SA entries in SA-cache. The range is from 1 to 500000.
show ip msdp — displays the MSDP information. ip msdp shutdown Administratively shut down a configured MSDP peer. S6000 Syntax Parameters ip msdp shutdown {peer address} peer address Enter the peer address in a dotted decimal format (A.B.C.D.). Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 6.2.1.1 Introduced show ip msdp Display the MSDP peer status, SA cache, or peer summary.
Peer Addr: 100.1.1.1 Local Addr: 100.1.1.2(639) Connect Source: none State: Established Up/Down Time: 00:00:08 Timers: KeepAlive 60 sec, Hold time 75 sec SourceActive packet count (in/out): 0/0 SAs learned from this peer: 0 SA Filtering: Input (S,G) filter: none Output (S,G) filter: none Dell# Example (Sa-cache) Dell#show ip msdp sa-cache MSDP Source-Active Cache - 1 entries GroupAddr SourceAddr RPAddr 224.1.1.1 172.21.220.10 172.21.3.
UpTime 00:00:13 00:00:13 00:00:13 00:00:13 00:00:13 00:00:13 00:00:13 00:00:13 00:00:13 00:00:13 00:00:13 00:00:13 00:00:13 00:00:13 00:00:13 00:00:13 00:00:13 00:00:13 00:00:13 00:00:13 862 GroupAddr SourceAddr 225.1.2.1 10.1.1.3 225.1.2.2 10.1.1.4 225.1.2.3 10.1.1.3 225.1.2.4 10.1.1.4 225.1.2.5 10.1.1.3 225.1.2.6 10.1.1.4 225.1.2.7 10.1.1.3 225.1.2.8 10.1.1.4 225.1.2.9 10.1.1.3 225.1.2.10 10.1.1.4 225.1.2.11 10.1.1.3 225.1.2.11 10.1.1.3 225.1.2.12 10.1.1.4 225.1.2.13 10.1.1.3 225.1.2.14 10.1.1.4 225.1.
32 Multiple Spanning Tree Protocol (MSTP) Multiple spanning tree protocol (MSTP), as implemented by the Dell Networking operating system, conforms to IEEE 802.1s. This command supports the Dell Networking S6000 platform. debug spanning-tree mstp Enable debugging of the multiple spanning tree protocol and view information on the protocol.
Example Version Description 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series.
Related Commands protocol spanning-tree mstp — enters MULTIPLE SPANNING TREE mode. forward-delay The amount of time the interface waits in the Blocking State and the Learning State before transitioning to the Forwarding State. S6000 Syntax forward-delay seconds To return to the default setting, use the no forward-delay command. Parameters seconds Enter the number of seconds the interface waits in the Blocking State and the Learning State before transiting to the Forwarding State.
hello-time Set the time interval between generation of MSTB bridge protocol data units (BPDUs). S6000 Syntax hello-time seconds To return to the default value, use the no hello-time command. Parameters seconds Enter a number as the time interval between transmission of BPDUs. The range is from 1 to 10. The default is 2 seconds. Defaults 2 seconds Command Modes MULTIPLE SPANNING TREE Command History This guide is platform-specific.
Parameters max-age Enter a number of seconds the Dell Networking OS waits before refreshing configuration information. The range is from 6 to 40. The default is 20 seconds. Defaults 20 seconds Command Modes MULTIPLE SPANNING TREE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Valid priority values are: 0, 4096, 8192, 12288, 16384, 20480, 24576, 28672, 32768, 36864, 40960, 45056, 49152, 53248, 57344, and 61440. All other values are rejected. Defaults default bridge-priority is 32768. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.5.1.0 Introduced. Usage Information For two MSTP switches to be within the same MSTP region, the switches must share the same region name (including matching case). Related Commands msti — maps the VLAN(s) to an MST instance.
Usage Information Version Description pre-6.2.1.1 Introduced on the E-Series. MSTP is not enabled when you enter MULTIPLE SPANNING TREE mode. To enable MSTP globally on the switch, enter the no disable command while in MULTIPLE SPANNING TREE mode. For more information about the multiple spanning tree protocol, refer to the Dell Networking OS Configuration Guide. Example Dell(conf)#protocol spanning-tree mstp Dell(config-mstp)#no disable Related Commands disable — disables multiple spanning tree.
Usage Information For two MSTP switches to be within the same MST region, the switches must share the same revision number. Related Commands msti — maps the VLAN(s) to an MST instance. name — assigns the region name to the MST region. show config View the current configuration for the mode. Only non-default values are shown. S6000 Syntax show config Command Modes MULTIPLE SPANNING TREE Command History This guide is platform-specific.
show spanning-tree mst configuration View the multiple spanning tree configuration. S6000 Syntax show spanning-tree mst configuration Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
guard Command Modes Command History • EXEC • EXEC Privilege (Optional) Enter the keyword guard to display the type of guard enabled on an MSTP interface and the current port state. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Designated bridge has priority 16384, address 0001.e800.0a:5c Designated port id is 128.89, designated path cost Number of transitions to forwarding state 3 BPDU (Mrecords): sent 7, received 1103 The port is not in the portfast mode Example (EDS and LBK) The bold line shows the loopback BPDU inconsistency (LBK_INC). Dell#show spanning-tree msti 0 brief MSTI 0 VLANs mapped 1-4094 Executing IEEE compatible Spanning Tree Protocol Root ID Priority 32768, Address 0001.e801.
Example (Guard) Dell#show spanning-tree msti 5 guard Interface Name Instance Sts Guard type -----------------------------------Te 1/1 5 INCON(Root) Rootguard Te 1/2 5 FWD Loopguard Te 1/3 5 EDS(Shut) Bpduguard spanning-tree Enable the multiple spanning tree protocol on the interface. S6000 Syntax spanning-tree To disable the multiple spanning tree protocol on the interface, use the no spanning-tree command. Parameters spanning-tree Enter the keywords spanning-tree to enable the MSTP on the interface.
spanning-tree msti Configure multiple spanning tree instance cost and priority for an interface. S6000 Syntax spanning-tree msti instance {cost cost | priority priority} Parameters msti instance Enter the keyword msti and the MST instance number. The range is from zero (0) to 63. cost cost (OPTIONAL) Enter the keyword cost then the port cost value. The range is from 1 to 200000.
tc-flush-standard Enable the MAC address flushing after receiving every topology change notification. S6000 Syntax tc-flush-standard To disable, use the no tc-flush-standard command. Defaults Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
33 Multicast The multicast commands are supported by Dell Networking operating system (OS) on all S6000 platform. This chapter contains the following sections: • IPv4 Multicast Commands IPv4 Multicast Commands The following section contains the IPv4 multicast commands. clear ip mroute Clear learned multicast routes on the multicast forwarding table. To clear the protocol-independent multicast (PIM) tree information base, use the clear ip pim tib command.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the C-Series. E-Series legacy command Related Commands show ip pim tib — shows the PIM tree information base. ip mroute Assign a static mroute.
distance (OPTIONAL) Enter a number as the distance metric assigned to the mroute. The range is from 0 to 255. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000-ON. 9.2(1.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the C-Series. 7.6.1.0 Introduced on the E-Series. This feature allows you to limit the number of multicast entries on the system. This number is the total of all the multicast entries on all line cards in the system. On each line card, the multicast module only installs the maximum number of entries, depending on the configured CAM profile. To store multicast routes, use the IN-L3-McastFib CAM partition.
Usage Information After you enable multicast, you can enable IGMP and PIM on an interface. In INTERFACE mode, enter the ip pim sparse-mode command to enable IGMP and PIM on the interface. Related Commands ip pim sparse-mode — enables IGMP and PIM on an interface. show ip mroute View the multicast routing table. Syntax show ip mroute [vrf vrf-name] [static | group-address [source-address] | count | snooping [vlan vlan-idIntroduced on the S6000-ON.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000-ON. 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 9.2.(0.0) Added support for keyword vlt to the Z9000, S4810, and S4820T. 8.4.1.1 Support for the keyword snooping and the optional vlan vlan-id, groupaddress, and source-address parameters were added on E-Series ExaScale. 8.3.19.0 Introduced on the S4820T. 8.3.7.
Spanned outgoing interface list: Vlan 20 (S) Usage Information Example The following describes the show ip mroute command shown in the following example. Field Description (S, G) Displays the forwarding entry in the multicast route table. uptime Displays the amount of time the entry has been in the multicast forwarding table. Incoming interface Displays the reverse path forwarding (RPF) information towards the source for (S,G) entries and the RP for (*,G) entries.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.1 Introduced on the S4810. E-Series legacy command Usage Information Network administrators use static mroutes to control the reach-ability of the multicast sources.
34 Neighbor Discovery Protocol (NDP) The neighbor discovery protocol for IPv6 is defined in RFC 2461 as part of the Stateless Address Autoconfiguration protocol. It replaces the Address Resolution Protocol used with IPv4.
clear ipv6 neighbors Delete all entries in the IPv6 neighbor discovery cache or neighbors of a specific interface. Static entries are not removed using this command. S6000 Syntax Parameters clear ipv6 neighbors [vrf vrf-name] [ipv6-address | interface] vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to clear the neighbor corresponding to that VRF. NOTE: If you do not specify this option, the neighbors in the default VRF are cleared.
debug ipv6 nd ra-guard Enable debugging for IPv6 RA guard snooping information. Syntax debug ipv6 nd ra-guard [interface_type slot/port | count value] Parameters interface_type slot/ port count value Enter the one of the following interfaces and slot/port information: • For a port channel interface, enter the keywords port-channel then a number. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
Related Commands Version Description 9.7(0.0) Introduced on the S4810, S4820T, S5000, S6000, and Z9000 switches. • ipv6 nd raguard policy policy-name — Defines the RA guard policy name and enter the RA guard policy configuration mode. • ipv6 nd ra-guard enable — Allows you to configure the RA guard related commands. hop-limit Enable the verification of the advertised hop count limit. If this command is not configured, the verification process is bypassed.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.7(0.0) Introduced on the S4810, S4820T, S5000, S6000, and Z9000 switches.
Related Commands ipv6 nd ra-guard enable — Allows you to configure the RA guard related commands. ipv6 neighbor Configure a static entry in the IPv6 neighbor discovery. S6000 Syntax ipv6 neighbor [vrf vrf-name] {ipv6-address} {interface interface} {hardware_address} To remove a static IPv6 entry from the IPv6 neighbor discovery, use the no ipv6 neighbor [vrf vrf-name] {ipv6-address} {interface interface} command.
managed-config-flag Set the managed address configuration flag. Syntax managed-config-flag {on | off} To clear the flag, use the no managed-config-flag {on | off} command. Parameters on Enter the keyword on to set the managed-config-flag value as ON. off Enter the keyword off to set the managed-config flag value as OFF. Defaults none Command Modes POLICY LIST CONFIGURATION Command History This guide is platform-specific.
The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.7(0.0) Introduced on the S4810, S4820T, S5000, S6000, and Z9000 switches. • ipv6 nd ra-guard enable — Allows you to configure the RA guard related commands. • ipv6 nd raguard policy policy-name — Defines the RA guard policy name and enter the RA guard policy configuration mode.
To reset the MTU value, use the no mtu value command. Parameters value Enter the maximum transmission unit value in bytes. The range is from 1,280 to 11,982 bytes. Defaults 0 Command Modes POLICY LIST CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
reachable-time Enable the verification of the configured reachability time in the received RA packets. Syntax reachable—time value To reset the advertised reachability time, use the no reachable-timevalue command. Parameters value Enter the advertised reachability time in milliseconds. The range is from 0 to 3,600,000 milliseconds. Defaults none Command Modes POLICY LIST CONFIGURATION Command History This guide is platform-specific.
Related Commands ipv6 nd raguard policy policy-name — Defines the router advertisement (RA) guard policy name and enter the RA guard policy configuration mode. router-lifetime Set the router lifetime. Syntax router—lifetime value Parameters value Enter the router lifetime in seconds. The range is from 0 to 9,000 seconds. Defaults none Command Modes POLICY LIST CONFIGURATION Command History This guide is platform-specific.
Related Commands Version Description 9.7(0.0) Introduced on the S4810, S4820T, S5000, S6000, and Z9000 switches. • ipv6 nd ra-guard enable — Allow you to configure the RA guard related commands. • ipv6 nd raguard policy policy-name — Defines the router advertisement (RA) guard policy name and enter the RA guard policy configuration mode. show config Display the RA guard policy mode configurations.
show ipv6 nd ra-guard policy Display the configurations applied on all the RA guard policies or a specific RA guard policy. Syntax show ipv6 nd ra-guard policy policy-name Parameter policy policy-name Enter the keyword policy then the policy name. The policy name allows a maximum of 140 characters. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
show ipv6 neighbors Display IPv6 discovery information. Entering the command without options shows all IPv6 neighbor addresses stored on the control processor (CP).
trusted-port Allow bypassing the configured RA guard validation and forwards the RA packets received on the interface, which has the trusted port policy attached. Syntax trusted-port To reset the policy applied to the trusted port, use the no trusted-port command. Defaults none Command Modes POLICY LIST CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
35 Object Tracking Object Tracking supports IPv4 and IPv6, and is available on the Dell Networking, C-Series, E-Series, S-Series, and S4810 platforms. Object tracking allows you to define objects of interest, monitor their state, and report to a client when a change in an object’s state occurs.
Example Version Description 8.4.1.0 Introduced. Dell#debug track all 04:35:04: %RPM0-P:RP2 %OTM-5-STATE: track 6 - Interface TenGigabitEthernet 1/2 line-protocol DOWN 04:35:04: %RPM0-P:RP2 %OTM-5-NOTIF: VRRP notification: resource ID 6 DOWN delay Configure the time delay used before communicating a change in the status of a tracked object to clients. Syntax delay {[up seconds] [down seconds]} To return to the default setting, use the no delay command.
description Enter a description of a tracked object. Syntax description {text} To remove the description, use the no description {text} command. Parameters text Enter a description to identify a tracked object (80 characters maximum). Defaults none Command Modes OBJECT TRACKING (conf_track_object-id) Command History Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 8.3.12.0 Introduced on the S4810. 8.4.1.0 Introduced.
track 4 interface TenGigabitEthernet 1/2 ip routing track 5 ip route 192.168.0.0/24 reachability vrf red track resolution ip route isis 20 track resolution ip route ospf 10 Example (Object-id) Dell#show running-config track 300 track 300 ip route 10.0.0.0/8 metric threshold delay down 3 delay up 5 threshold metric up 100 Related Commands • show track – displays information about tracked objects, including configuration, current state, and clients which track the object.
Example Output Description Track object-id Displays the number of the tracked object. Interface type slot/ port, IP route ipaddress, IPv6 route ipv6-address Displays the interface type and slot/port number or address of the IPv4/IPv6 route that is being tracked. object is Up/Down Up/Down state of tracked object; for example, IPv4 interface, reachability or metric threshold of an IP route.
Related Commands • show running-config track – displays configuration information about tracked objects. • track interface ip routing – configures object tracking on the routing status of an IPv4 Layer 3 interface. • track interface line-protocol – configures object tracking on the line-protocol state of a Layer 2 interface. • track ip route metric threshold – configures object tracking on the threshold of an IPv4 route metric.
The tracking process uses a protocol-specific resolution value to convert the actual metric in the routing table to a scaled metric in the range 0 to 255. You can configure the resolution value used to scale route metrics for supported protocols with the track resolution ip route and track resolution ipv6 route commands. Related Commands • track ip route metric threshold – configures object tracking on the threshold of an IPv4 route metric.
track interface line-protocol Configure object tracking on the line-protocol state of a Layer 2 interface. Syntax track object-id interface interface line-protocol To return to the default setting, use the no track object-id command. Parameters object-id Enter the ID number of the tracked object. The range is 1 to 500.
ip-address/ prefixlen Enter an IPv4 address in dotted decimal format. The valid IPv4 prefix lengths are from /0 to /32. vrf vrf-name (Optional) E-Series only: You can configure a VPN routing and forwarding (VRF) instance to specify the virtual routing table to which the tracked route belongs. Defaults none Command Modes CONFIGURATION Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 8.3.12.0 Introduced on the S4810. 8.4.1.0 Introduced.
Parameters object-id Enter the ID number of the tracked object. The range is 1 to 500. ip-address/ prefixlen Enter an IPv4 address in dotted decimal format. The valid IPv4 prefix lengths are from /0 to /32. vrf vrf-name (Optional) E-Series only: You can configure a VPN routing and forwarding (VRF) instance to specify the virtual routing table to which the tracked route belongs. Defaults none Command Modes CONFIGURATION Command History Usage Information Version Description 9.7(0.
Defaults none Command Modes CONFIGURATION Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 8.3.12.0 Introduced on the S4810. 8.4.1.0 Introduced. Use this command to configure the protocol-specific resolution value that converts the actual metric of an IPv4 route in the routing table to a scaled metric in the range 0 to 255.
show track ipv6 route Display information about all tracked IPv6 routes, including configuration, current tracked state (UP or DOWN), and the clients which are tracking an object. Syntax show track ipv6 route [brief] Parameters Command Modes Command History Usage Information Example brief • EXEC • EXEC Privilege (OPTIONAL) Display a single line summary of information for tracked IPv6 routes. Version Description 9.7(0.0) Introduced on the S6000-ON. 8.3.12.0 Introduced on the S4810. 8.4.1.
Usage Command Example (Brief) The following describes the show track ipv6 route brief command shown in the Example below. Ouput Description ResID Number of the tracked object. Resource Type of tracked object. Parameter Detailed description of the tracked object. State Up or Down state of the tracked object. Last Change Time since the last change in the state of the tracked object.
Usage Information Related Commands Version Description 8.3.12.0 Introduced on the S4810. 8.4.1.0 Introduced. Use this command to create an object that tracks the routing state of an IPv6 Layer 3 interface: • The status of the IPv6 interface is UP only if the Layer 2 status of the interface is UP and the interface has a valid IP address.
considers a lower value to have priority over a higher value. The resulting scaled value is compared against the configured threshold values to determine the state of a tracked route as follows: • If the scaled metric for a route entry is less than or equal to the UP threshold, the state of a route is UP. • If the scaled metric for a route is greater than or equal to the DOWN threshold or the route is not entered in the routing table, the state of a route is DOWN.
If the next-hop address in the ARP cache ages out for a route tracked for its reachability, an attempt is made to regenerate the ARP cache entry to if the next-hop address appears before considering the route DOWN. Related Commands • show track ipv6 route – displays information about tracked IPv6 routes, including configuration, current state, and clients which track the route. • track ipv6 route reachability – configures object tracking on the reachability of an IPv4 route.
Related Commands • threshold metric – configures the metric threshold used to determine the UP and/or DOWN state of a tracked route. • track ipv6 route metric threshold – configures object tracking on the threshold of an IPv6 route metric.
36 Open Shortest Path First (OSPFv2 and OSPFv3) Open Shortest Path First version 2 for IPv4 is supported on platform. OSPF is an Interior Gateway Protocol (IGP), which means that it distributes routing information between routers in a single Autonomous System (AS). OSPF is also a link-state protocol in which all routers contain forwarding tables derived from information about their links to their neighbors.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for the Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for the Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. area range Summarize routes matching an address/mask at an area border router (ABR).
Version Description pre- 6.1.1.1 Introduced on the E-Series. Usage Information Only the routes within an area are summarized, and that summary is advertised to other areas by the ABR. External routes are not summarized. Related Commands area stub — creates a stub area. router ospf — enters ROUTER OSPF mode to configure an OSPF instance. area stub Configure a stub area, which is an area not connected to other areas.
auto-cost Specify how the OSPF interface cost is calculated based on the reference bandwidth method. S6000 Syntax auto-cost [reference-bandwidth ref-bw] To return to the default bandwidth or to assign cost based on the interface type, use the no auto-cost [reference-bandwidth] command. Parameters ref-bw (OPTIONAL) Specify a reference bandwidth in megabits per second. The range is from 1 to 4294967. The default is 100 megabits per second. Defaults 100 megabits per second.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.
neighbor router-id (OPTIONAL) Enter the keyword neighbor then the neighbor’s router-id in dotted decimal format (A.B.C.D.). Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.4(0.0) Added support for VRF. Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.8.
Example Field Description auk: If the ip ospf authentication-key command is configured, this field displays the key used. keyid: If the ip ospf message-digest-key command is configured, this field displays the MD5 key to: Displays the interface to which the packet is intended. dst: Displays the destination IP address. netmask: Displays the destination IP address mask.
metric metric-value (OPTIONAL) Enter the keyword metric then a number to configure a metric value for the route. The range is from 1 to 16777214. metric-type typevalue (OPTIONAL) Enter the keywords metric-type then an OSPF link state type of 1 or 2 for default routes. The values are: route-map mapname • 1 = Type 1 external route • 2 = Type 2 external route (OPTIONAL) Enter the keywords route-map then the name of an established route map. Defaults Disabled.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for the Multi-Process OSPF. 7.
Related Commands Version Description 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. show ip ospf asbr — displays the VLAN configuration. distance Define an administrative distance for particular routes to a specific IP address. S6000 Syntax distance weight [ip-address mask access-list-name] To delete the settings, use the no distance weight [ip-address mask access-list-name] command. Parameters weight Specify an administrative distance. The range is from 1 to 255.
distance ospf Configure an OSPF distance metric for different types of routes. S6000 Syntax distance ospf [external dist3] [inter-area dist2] [intra-area dist1] To delete these settings, use the no distance ospf command. Parameters Defaults external dist3 (OPTIONAL) Enter the keyword external then a number to specify a distance for external type 5 and 7 routes. The range is from 1 to 255. The default is 110.
distribute-list in Apply a filter to incoming routing updates from OSPF to the routing table. S6000 Syntax distribute-list prefix-list-name in [interface] To delete a filter, use the no distribute-list prefix-list-name in [interface] command. Parameters prefix-list-name Enter the name of a configured prefix list. interface (OPTIONAL) Enter one of the following keywords and slot/port or number information: • For Port Channel groups, enter the keywords port-channel then a number.
distribute-list out To restrict certain routes destined for the local routing table after the SPF calculation, apply a filter. S6000 Syntax distribute-list prefix-list-name out [bgp | connected | isis | rip | static] To remove a filter, use the no distribute-list prefix-list-name out [bgp | connected | isis | rip | static] command. Parameters prefix-list-name Enter the name of a configured prefix list. bgp (OPTIONAL) Enter the keyword bgp to specify that BGP routes are distributed.
Usage Information Version Description pre- 6.1.1.1 Introduced on the E-Series. The distribute-list out command applies to routes autonomous system boundary routers (ASBRs) redistributes into OSPF. It can be applied to external type 2 and external type 1 routes, but not to intra-area and inter-area routes. fast-convergence This command sets the minimum LSA origination and arrival times to zero (0), allowing more rapid route computation so that convergence takes less time.
flood-2328 Enable RFC-2328 flooding behavior. S6000 Syntax flood-2328 To disable, use the no flood-2328 command. Defaults Disabled. Command Modes ROUTER OSPF Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
To disable the grace period, use the no graceful-restart grace-period command. Parameters seconds Time duration, in seconds, that specifies the duration of the restart process before OSPF terminates the process. The range is from 40 to 1800 seconds. Defaults Not Configured Command Modes ROUTER OSPF Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.12.0 Introduced on the S4810. 7.8.1.0 Restart role enabled on the S-Series (Both Helper and Restart roles now supported on S-Series). Added support for Multi-Process OSPF. 7.7.1.0 Added Helper-Role support on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series.
graceful-restart role Specify the role for your OSPF router during graceful restart. S6000 Syntax graceful-restart role [helper-only | restart-only] To disable graceful restart role, use the no graceful-restart role command. Parameters role helper-only (OPTIONAL) Enter the keywords helper-only to specify the OSPF router is a helper only during graceful restart. role restart-only (OPTIONAL) Enter the keywords restart-only to specify the OSPF router is a restart only during graceful-restart.
Defaults zero (0) seconds. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810.
Usage Information Version Description 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. All neighboring routers in the same network must use the same password to exchange OSPF information. ip ospf cost Change the cost associated with the OSPF traffic on an interface. S6000 Syntax ip ospf cost cost To return to default value, use the no ip ospf cost command. Parameters cost Enter a number as the cost. The range is from 1 to 65535.
ip ospf dead-interval Set the time interval since the last hello-packet was received from a router. After the interval elapses, the neighboring routers declare the router dead. S6000 Syntax ip ospf dead-interval seconds To return to the default values, use the no ip ospf dead-interval command. Parameters seconds Enter the number of seconds for the interval. The range is from 1 to 65535. The default is 40 seconds.
Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. You can configure a maximum of six digest keys on an interface. Of the available six digest keys, the switches select the MD5 key that is common. The remaining MD5 keys are unused. To change to a different key on the interface, enable the new key while the old key is still enabled.
ip ospf network Set the network type for the interface. S6000 Syntax ip ospf network {broadcast | point-to-point} To return to the default, use the no ip ospf network command. Parameters broadcast Enter the keyword broadcast to designate the interface as part of a broadcast network. point-to-point Enter the keywords point-to-point to designate the interface as part of a point-to-point network. Defaults Broadcast. Command Modes ROUTER OSPF Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. Set the time interval to a number large enough to prevent unnecessary retransmissions. ip ospf transmit-delay To send a link state update packet on the interface, set the estimated time elapsed.
log-adjacency-changes To send a Syslog message about changes in the OSPF adjacency state, set Dell Networking OS. S6000 Syntax log-adjacency-changes To disable the Syslog messages, use the no log-adjacency-changes command. Defaults Disabled. Command Modes ROUTER OSPF Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.1(0.0) Introduced support for OSPFv3 on the S4810 and Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
If an OSPF process has been selected, it must be disabled prior to assigning new process ID the MIB responsibility. network area Define which interfaces run OSPF and the OSPF area for those interfaces. S6000 Syntax network ip-address mask area area-id To disable an OSPF area, use the no network ip-address mask area area-id command. Parameters ip-address Specify a primary or secondary address in dotted decimal format. The primary address is required before adding the secondary address.
passive-interface Suppress both receiving and sending routing updates on an interface. S6000 Syntax passive-interface {default | interface} To enable both the receiving and sending routing, use the no passive-interface interface command. To return all OSPF interfaces (current and future) to active, use the no passive-interface default command. Parameters default Enter the keyword default to make all OSPF interfaces (current and future) passive.
Usage Information Although the passive interface does not send or receive routing updates, the network on that interface is still included in OSPF updates sent using other interfaces. The default keyword sets all interfaces as passive. You can then configure individual interfaces, where adjacencies are desired, using the no passive-interface interface command.
isis Enter the keyword isis to specify that ISO IS-IS information is redistributed. ospf Enter the keyword ospf to specify that information corresponding to OSPF is redistributes. rip Enter the keyword rip to specify that RIP routing information is redistributed. static Enter the keyword static to specify that information from static routes is redistributed. metric metric-value (OPTIONAL) Enter the keyword metric then a number. The range is from 0 (zero) to 16777214.
redistribute bgp Redistribute BGP routing information throughout the OSPF instance. S6000 Syntax redistribute bgp as number [metric metric-value] | [metric-type type-value] | [tag tag-value] To disable redistribution, use the no redistribute bgp as number [metric metric-value] | [metric-type type-value] [route-map map-name] [tag tag-value] command. Parameters as number Enter the autonomous system number. The range is from 1 to 65535.
redistribute isis Redistribute IS-IS routing information throughout the OSPF instance. S6000 Syntax redistribute isis [tag] [level-1 | level-1-2 | level-2] [metric metricvalue | metric-type type-value] [route-map map-name] [tag tag-value] To disable redistribution, use the no redistribute isis [tag] [level-1 | level-1-2 | level-2] [metric metric-value | metric-type type-value] [route-map mapname] [tag tag-value] command. Parameters tag (OPTIONAL) Enter the name of the IS-IS routing process.
Version Description 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. router-id To configure a fixed router ID, use this command. S6000 Syntax router-id ip-address To remove the fixed router ID, use the no router-id ip-address command. Parameters ip-address Enter the router ID in the IP address format. Defaults none. Command Modes ROUTER OSPF Command History This guide is platform-specific.
Changing router-id will bring down existing OSPF adjacency [y/n]: Dell# router ospf To configure an OSPF instance, enter ROUTER OSPF mode. S6000 Syntax router ospf process-id [vrf {vrf name}] To clear an OSPF instance, use the no router ospf process-id command. Parameters process-id Enter a number for the OSPF instance. The range is from 1 to 65535. vrf name (Optional) Enter the VRF process identifier to tie the OSPF instance to the VRF.
show config Display the non-default values in the current OSPF configuration. S6000 Syntax show config Command Modes ROUTER OSPF Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.8.0 Added output for LSA throttling timers. 8.3.7.0 Introduced on the S4810. 7.9.1.0 Added support for VRF. 7.8.1.0 Added support of Multi-Process OSPF. 7.8.1.
show ip ospf interface — displays the OSPF interfaces configured. show ip ospf neighbor — displays the OSPF neighbors configured. show ip ospf asbr Display all autonomous system boundary router (ASBR) routers visible to OSPF. S6000 Syntax show ip ospf [process-id | vrf vrf-name] asbr Parameters Defaults process-id Enter the OSPF Process ID to show a specific process. If no Process ID is entered, command applies only to the first OSPF process.
You can determine if an ASBR is in a directly connected area (or not) by the flags. For ASBRs in a directly connected area, E flags are set. In the following example, router 1.1.1.1 is in a directly connected area since the Flag is E/-/-/. For remote ASBRs, the E flag is clear (-/-/-/). Example Dell#show ip ospf 1asbr RouterID 3.3.3.3 1.1.1.1 Dell# Flags -/-/-/ E/-/-/ Cost Nexthop 2 10.0.0.2 0 0.0.0.0 Interface Area Te 1/1 1 0 show ip ospf database Display all LSA information.
Example Field Description Link ID Identifies the router ID. ADV Router Identifies the advertising router’s ID. Age Displays the link state age. Seq# Identifies the link state sequence number. This number allows you to identify old or duplicate link state advertisements. Checksum Displays the Fletcher checksum of an LSA’s complete contents. Link count Displays the number of interfaces for that router. Dell>show ip ospf 1 database OSPF Router with ID (11.1.2.1) (Process ID 1) Router (Area 0.0.
link-state-id adv-router ipaddress Command Modes Command History • EXEC • EXEC Privilege (OPTIONAL) Specify LSA ID in dotted decimal format. The LSA ID value depends on the LSA type, and it can be one of the following: • the network’s IP address for Type 3 LSAs or Type 5 LSAs • the router’s OSPF router ID for Type 1 LSAs or Type 4 LSAs • the default destination (0.0.0.
Example Field Description Advertising Router Identifies the advertising router’s ID. Checksum Displays the Fletcher checksum of the LSA’s complete contents. Length Displays the length in bytes of the LSA. Network Mask Displays the network mask implemented on the area. TOS Displays the Type of Service (TOS) options. Option 0 is the only option. Metric Displays the LSA metric. Dell#show ip ospf 100 database asbr-summary OSPF Router with ID (1.1.1.10) (Process ID 100) Summary Asbr (Area 0.0.0.
• adv-router ipaddress Command Modes Command History • EXEC • EXEC Privilege the default destination (0.0.0.0) for Type 5 LSAs (OPTIONAL) Enter the keywords adv-router and the ip-address to display only the LSA information about that router. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Example Field Description Length Displays the length in bytes of the LSA. Network Mask Displays the network mask implemented on the area. Metrics Type Displays the external type. TOS Displays the Type of Service (TOS) options. Option 0 is the only option. Metric Displays the LSA metric. Forward Address Identifies the address of the forwarding router. Data traffic is forwarded to this router. If the forwarding address is 0.0.0.0, data traffic is forwarded to the originating router.
show ip ospf database network Display the network (type 2) LSA information. S6000 Syntax Parameters show ip ospf [process-id | vrf vrf-name] database network [link-state-id] [adv-router ip-address] process-id Enter the OSPF Process ID to show a specific process. If no Process ID is entered, command applies only to the first OSPF process. vrf vrf-name Enter the keyword vrf followed by the name of the VRF to view the network LSA information corresponding to an OSPF process that is tied to a specific VRF.
Example Field Description LS Age Displays the LSA’s age. Options Displays the optional capabilities available on router. The following options can be found in this item: • TOS-capability or No TOS-capability is displayed depending on whether the router can support Type of Service. • DC or No DC is displayed depending on whether the originating router can support OSPF over demand circuits. • E or No E is displayed on whether the originating router can accept AS External LSAs.
show ip ospf database nssa-external Display NSSA-External (type 7) LSA information. S6000 Syntax Parameters show ip ospf [process-id | vrf vrf-name] database nssa-external [linkstate-id] [adv-router ip-address] process-id Enter the OSPF Process ID to show a specific process. If no Process ID is entered, command applies only to the first OSPF process.
show ip ospf database opaque-area Display the opaque-area (type 10) LSA information. S6000 Syntax show ip ospf [process-id | vrf vrf-name] database opaque-area [link-stateid] [adv-router ip-address] Parameters process-id Enter the OSPF Process ID to show a specific process. If no Process ID is entered, command applies only to the first OSPF process.
Example Item Description LS Age Displays the LSA’s age. Options Displays the optional capabilities available on router. The following options can be found in this item: • TOS-capability or No TOS-capability is displayed depending on whether the router can support Type of Service. • DC or No DC is displayed depending on whether the originating router can support OSPF over demand circuits. • E or No E is displayed on whether the originating router can accept AS External LSAs.
Parameters process-id Enter the OSPF Process ID to show a specific process. If no Process ID is entered, command applies only to the first OSPF process. link-state-id (OPTIONAL) Specify LSA ID in dotted decimal format.
link-state-id adv-router ipaddress Command Modes Command History • EXEC • EXEC Privilege (OPTIONAL) Specify LSA ID in dotted decimal format. The LSA ID value depends on the LSA type, and it can be one of the following: • the network’s IP address for Type 3 LSAs or Type 5 LSAs • the router’s OSPF router ID for Type 1 LSAs or Type 4 LSAs • the default destination (0.0.0.
adv-router ipaddress Command Modes Command History • EXEC • EXEC Privilege • the network’s IP address for Type 3 LSAs or Type 5 LSAs • the router’s OSPF router ID for Type 1 LSAs or Type 4 LSAs • the default destination (0.0.0.0) for Type 5 LSAs (OPTIONAL) Enter the keywords adv-router followed by the IP address of an Advertising Router to display only the LSA information about that router. This guide is platform-specific.
Example Item Description LS Seq Number Displays the link state sequence number. This number detects duplicate or old LSAs. Checksum Displays the Fletcher checksum of an LSA’s complete contents. Length Displays the length in bytes of the LSA. Number of Links Displays the number of active links to the type of router (Area Border Router or AS Boundary Router) listed in the previous line. Link connected to: Identifies the type of network to which the router is connected.
Number of TOS metric: 0 TOS 0 Metric: 1 Link connected to: a Stub Network (Link ID) Network/subnet number: 11.1.5.0 --More-Related Commands show ip ospf database — displays OSPF database information. show ip ospf database summary Display the network summary (type 3) LSA routing information. S6000 Syntax show ip ospf [process-id | vrf vrf-name] database summary [link-state-id] [adv-router ip-address] Parameters process-id Enter the OSPF Process ID to show a specific process.
Usage Information Example Version Description 7.5.1.0 Introduced on the C-Series. pre-6.1.1.1 Introduced on the E-Series. The following describes the show ip ospf process-id database summary command shown in the following example. Item Description LS Age Displays the LSA age. Options Displays the optional capabilities available on router.
Length: 28 Network Mask: /24 TOS: 0 Metric: 1 LS age: 7 Options: (No TOS-capability, No DC, E) LS type: Summary Network Link State ID: 192.68.33.0 Advertising Router: 1.1.1.10 LS Seq Number: 0x80000016 Checksum: 0x1241 Length: 28 Network Mask: /26 TOS: 0 Metric: 1 Dell# Related Commands show ip ospf database — displays OSPF database information. show ip ospf interface Display the OSPF interfaces configured. If OSPF is not enabled on the switch, no output is generated.
Usage Information Example Version Description 9.4.(0.0) Added support for VRF. 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.1 Introduced on the E-Series.
Internet Address 192.168.0.1/24, Area 0.0.0.1 Process ID 1, Router ID 192.168.253.2, Network Type BROADCAST, Cost: 1 Transmit Delay is 1 sec, State DROTHER, Priority 1 Designated Router (ID) 192.168.253.5, Interface address 192.168.0.4 Backup Designated Router (ID) 192.168.253.3, Interface address 192.168.0.2 Timer intervals configured, Hello 10, Dead 40, Wait 40, Retransmit 5 Hello due in 00:00:08 Neighbor Count is 3, Adjacent neighbor count is 2 Adjacent with neighbor 192.168.253.
Example Item Description Neighbor ID Displays the neighbor router ID. Pri Displays the priority assigned neighbor. State Displays the OSPF state of the neighbor. Dead Time Displays the expected time until FTOS declares the neighbor dead. Address Displays the IP address of the neighbor. Interface Displays the interface type slot/port information. Area Displays the neighbor’s area (process ID). Dell#show ip ospf 34 neighbor Neighbor ID 20.20.20.7 192.10.10.2 20.20.20.
Usage Information Version Description 7.8.1.0 Added support for Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series and E-Series. This command is useful in isolating routing problems between the OSPF and the RTM. For example, if a route is missing from the RTM/FIB but is visible from the display output of this command, the problem is with downloading the route to the RTM.
neighbor router-id Defaults Command Modes Command History • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a port channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. (OPTIONAL) Enter the keyword neighbor then the neighbor’s router-id in dotted decimal format (A.B.C.D.).
Row Heading Description TxQ-Len The transmission queue length. RxQ-Len The reception queue length. Tx-Mark The highest number mark in the transmission queue. Rx-Mark The highest number mark in the reception queue. Hello-Q The queue, for transmission or reception, for the hello packets. LSR-Q The queue, for transmission or reception, for the link state request packets.
Hello-Q LSR-Q Other-Q 0 0 0 0 0 0 0 0 0 2 0 0 Error packets (Only for RX) Intf-Down Wrong-Len Auth-Err Version No-Buffer Q-OverFlow 0 0 0 0 0 0 Non-Dr Invld-Nbr MD5-Err AreaMis Seq-No Unkown-Pkt 0 0 0 0 0 0 Self-Org 0 Nbr-State 0 Chksum 0 Conf-Issues 0 Socket 0 Error packets (Only for TX) Socket Errors Dell# Usage Information Example (Statistics) 0 The show ip ospf process-id statistics command displays the error packet count received on each interface as: • The hello-timer remaining value for
Parameters Defaults process-id Enter the OSPF Process ID to show a specific process. If no Process ID is entered, command applies only to the first OSPF process. vrf vrf-name Enter the keyword vrf followed by the name of the VRF to view LSAs corresponding to a specific VRF that are currently in queue waiting for timers to expire. none Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.1 Introduced on the E-Series.
• hold-interval: 5000 msec • max-interval: 5000 msec Command Modes ROUTER OSPF Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 9.0.2.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.8.0 Introduced on the S4810. OSPFv3 Commands Open shortest path first version 3 (OSPFv3) for IPv6 is supported on the platform. The fundamental mechanisms of OSPF (flooding, DR election, area support, SPF calculations, and so on) remain unchanged. However, OSPFv3 runs on a per-link basis instead of on a per-IP-subnet basis. Most changes were necessary to handle the increased address size of IPv6.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.1.(0.0) Introduced on the S4810 and Z9000. 8.3.19.0 Introduced on the S4820T. 8.4.2.0 Introduced on the E-Series TeraScale.
key-encryptionalgorithm (OPTIONAL) Specifies if the key is encrypted. Valid values: 0 (key is not encrypted) or 7 (key is encrypted). key Text string used in encryption. The required lengths of a non-encrypted or encrypted key are: 3DES - 48 or 96 hex digits; DES - 16 or 32 hex digits; AES-CBC -32 or 64 hex digits for AES-128 and 48 or 96 hex digits for AES-192. authenticationalgorithm Specifies the authentication algorithm to use for encryption. Valid values are MD5 or SHA1.
When you configure encryption for an OSPFv3 area with the area encryption command, you enable both IPsec encryption and authentication. However, when you enable authentication on an area with the area authentication command, you do not enable encryption at the same time. If you have enabled IPsec authentication in an OSPFv3 area with the area authentication command, you cannot use the area encryption command in the area at the same time.
debug ipv6 ospf bfd Display debug information and interface types for bidirectional forwarding detection (BFD) on OSPF IPv6 packets. Syntax Parameters [no] debug ipv6 ospf bfd [interface] interface (OPTIONAL) Enter one of the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
fe80:0000:0000:0000:0201:e8ff:fe8b:7720 Interface Te 1/2 IfIndex 34145282 00:59:27 : OSPFv3INFO: BFD parameters interval 100 min_rx 100 mult 3 role active 00:59:27 : OSPFv3INFO: BFD parameters interval 100 min_rx 100 mult 3 role active 00:59:27 : OSPFv3INFO: Completed Enabling BFD for NBRIP fe80:0000:0000:0000:0201:e8ff:fe8b:7720 Aug 25 11:19:59: %STKUNIT0-M:CP %BFDMGR-1-BFD_STATE_CHANGE: Changed session state to Init for neighbor fe80::201:e8ff:fe8b:7720 on interface Te 1/2 (diag: NBR_DN) Aug 25 11:20:00:
ID:223.255.255.255, Area ID:0, Chksum:a177, Inst:0, from Vl 100 05:20:25 : OSPFv3: Sending, Ver:3, Type:4(LS Update), Len:580, Router ID:223.255.255.254, Area ID:0, Inst:0, on Vl 1000 07:21:40 : OSPFv3: Received, Ver:3, Type:1(Hello), Len:40, Router ID: 223.255.255.254, Area ID:0, Chksum:af8f, Inst:0, from Te 1/6 Dell# Command Fields Lines Beginning With or Including Description OSPFv3... Debugging is on for all OSPFv3 packets and all interfaces. 05:21:01 Displays the time stamp.
• route-map mapname 2 = Type 2 external route (OPTIONAL) Enter the keywords route-map then the name of an established route map. Defaults Disabled. Command Modes ROUTER OSPFv3 Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.1.(0.
To enable OSPFv3 graceful restart, enter the ipv6 router ospf command to enter OSPFv3 configuration mode and then configure a grace period using the graceful-restart grace-period command. The grace period is the length of time that OSPFv3 neighbors continue to advertise the restarting router as though it is fully adjacent. When graceful restart is enabled (restarting role), an OSPFv3 restarting expects its OSPFv3 neighbors to help when it restarts by not advertising the broken link.
ipv6 ospf area Enable IPv6 OSPF on an interface. Syntax ipv6 ospf process id areaarea id To disable OSPFv6 routing for an interface, use the no ipv6 ospf process-id area area-id command. Parameters process-id Enter the process identification number. area area-id Specify the OSPF area. The range is from 0 to 65535. Defaults none Command Modes INTERFACE Command History Version Description 9.1.(0.0) Introduced on the S4810 and Z9000. 8.3.19.0 Introduced on the S4820T. 7.4.1.
Defaults Not configured. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.1.(0.0) Introduced on S4810 and Z9000. 8.4.2.0 Introduced on the E-Series. 8.3.19.0 Introduced on the S4820T.
Usage Information Version Description 9.1.(0.0) Introduced on the S4810 and Z9000. 7.8.1.0 Added support for C-Series. 7.4.1.0 Introduced on the E-Series. 8.3.19.0 Introduced on the S4820T.
ipv6 ospf encryption Configure an IPsec encryption policy for OSPFv3 packets on an IPv6 interface. Syntax Parameters ipv6 ospf encryption {null | ipsec spi number esp encryption-algorithm [key-encryption-type] key athentication-algorithm [key-encryption-type] key}} null Causes an encryption policy configured for the area to not be inherited on the interface. ipsec spi number Security Policy index (SPI) value that identifies an IPsec security policy. The range is from 256 to 4294967295.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.1.(0.0) Introduced on the S4810 and Z9000. 8.4.2.0 Introduced on the E-Series TeraScale. 8.3.19.0 Introduced on the S4820T. Before you enable IPsec encryption on an OSPFv3 interface, first enable IPv6 unicast routing globally, configure an IPv6 address and enable OSPFv3 on the interface, and assign the interface to an area.
When configured in a helper-reject role, an OSPFv3 router ignores the Grace LSAs that it receives from a restarting OSPFv3 neighbor. The graceful-restart role command is not supported in OSPFv3. When you enable the helper-reject role on an interface, you reconfigure an OSPFv3 router to function in a “restarting-only” role. ipv6 ospf hello-interval Specify the time interval between the hello packets sent on the interface.
Defaults 1 Command Modes INTERFACE Command History Usage Information Version Description 9.1.(0.0) Introduced on the S4810 and Z9000. 8.3.19.0 Introduced on the S4820T. 7.8.1.0 Added support for the C-Series. 7.4.1.0 Introduced on the E-Series. Setting a priority of 0 makes the router ineligible for election as a Designated Router or Backup Designated Router. Use this command for interfaces connected to multi-access networks, not point-to-point networks.
maximum-paths Enable the software to forward packets over multiple paths. Syntax maximum-paths number To disable packet forwarding over multiple paths, use the no maximum-paths command. Parameters number Defaults 8 Command Modes ROUTER OSPF Command History Specify the number of paths. The range is from 1 to 64. The default is 8 paths. Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.
advertises the router’s currently configured OSPF cost. Range: 5 to 86400 seconds. Defaults Not Configured. Command Modes ROUTER OSPF Command History Usage Information Version 9.1.(0.0) Introduced on the S4810 and Z9000. Version 8.4.2.5 Introduced on C-Series and E-Series TeraScale. Version 8.4.1.3 Introduced on E-Series ExaScale.
Dell(conf)#show ip ospf database router Exception Flag: Announcing maximum link costs LS age: 198 Options: (No TOS-capability, DC) LS Type: Router Links Link State ID: 2.1.1.1 Advertising Router: 2.1.1.1 LS Seq Number: 80000005 Checksum: 0x9F5D Length: 48 Number of Links: 2 passive-interface Disable (suppress) sending routing updates on an interface. Syntax passive—interface interface To enable sending routing updates on an interface, use the no passive-interface interface command.
OSPFv3 for IPv6 routing information is not sent or received through the specified router interface. The specified interface address appears as a stub network in the OSPFv3 for IPv6 domain. On configuring suppression using the passive-interface command, the state of the OSPF neighbor does not change to INIT; instead, the state of the OSPF neighbor changes to DOWN after the dead-timer expires. redistribute Redistribute into OSPFv3.
Defaults Not configured. Command Modes ROUTER OSPF for OSPFv2 ROUTER OSPFv3 for OSPFv3 Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.1.(0.0) Introduced support for OSPFv3 on the S4810 and Z9000. 8.3.19.0 Introduced on the S4820T. 7.8.1.0 Added support for the C-Series.
Usage Information You can configure an arbitrary value in the IP address for each router. However, each router ID must be unique. If this command is used on an OSPFv3 process that is already active (has neighbors), all the neighbor adjacencies are brought down immediately and new sessions are initiated with the new router ID. Related Commands clear ipv6 ospf process – resets an OSPFv3 router process. show crypto ipsec policy Display the configuration of IPsec authentication and encryption policies.
123456789a123456789b123456789c123456789d12345678 Outbound ESP Cipher Key : 123456789a123456789b123456789c123456789d12345678 Transform set : esp-3des esp-md5-hmac Crypto IPSec client security policy data Policy name : OSPFv3-0-501 Policy refcount : 1 Inbound ESP SPI : 501 (0x1F5) Outbound ESP SPI : 501 (0x1F5) Inbound ESP Auth Key : bbdd96e6eb4828e2e27bc3f9ff541e43faa759c9ef5706ba8ed8bb5efe91e97eb7c0 c30808825fb5 Outbound ESP Auth Key : bbdd96e6eb4828e2e27bc3f9ff541e43faa759c9ef5706ba8ed8bb5efe91e97eb7c0 c30
Parameters interface interface (OPTIONAL) Displays information about the SAs used on a specified OSPFv3 interface, where interface is one of the following values: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a port channel interface, enter the keywords port-channel then a number.
outbound esp sas Interface: TenGigabitEthernet 1/2 Link Local address: fe80::201:e8ff:fe40:4d11 IPSecv6 policy name: OSPFv3-1-600 inbound ah sas outbound ah sas inbound esp sas spi : 600 (0x258) transform : esp-des esp-sha1-hmac in use settings : {Transport, } replay detection support : N STATUS : ACTIVE outbound esp sas spi : 600 (0x258) transform : esp-des esp-sha1-hmac in use settings : {Transport, } replay detection support : N STATUS : ACTIVE show crypto ipsec sa ipv6 Command Fields Field Description
Parameters process-number Enter the OSPF process number. vrf vrf-name (Optional) Enter the keyword vrf followed by the name of the VRF to display neighbors corresponding to that VRF. NOTE: If you do not specify this option, neighbors corresponding to the default VRF are displayed. database-summary (OPTIONAL) Enter the keywords database-summary to view a summary of database LSA information.
Process 1 database summary Type Count/Status Oper Status 1 Admin Status 1 Area Bdr Rtr Status 1 AS Bdr Rtr Status 1 AS Scope LSA Count 0 AS Scope LSA Cksum sum 0 Originate New LSAS 50 Rx New LSAS 22 Ext LSA Count 0 Rte Max Eq Cost Paths 10 GR grace-period 180 GR mode planned and unplanned Area 0 database summary Type Count/Status Brd Rtr Count 1 AS Bdr Rtr Count 1 LSA count 6 Rtr LSA Count 2 Net LSA Count 1 Inter Area Pfx LSA Count 1 Inter Area Rtr LSA Count 0 Group Mem LSA Count 0 Type-7 LSA count 0 Intra
interface Defaults none Command Modes EXEC Command History Usage Information (OPTIONAL) Enter one of the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a port channel interface, enter the keywords port-channel then a number.
vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to display OSPF neighbors corresponding to that VRF. NOTE: If you do not specify this option, neighbors corresponding to the default VRF are displayed. interface Defaults none Command Modes EXEC (OPTIONAL) Enter the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
holdtime Defaults Enter a number as the hold time. The range is from 0 to 4294967295. The default is 10 seconds. • delay = 5 seconds • holdtime = 10 seconds Command Modes ROUTER OSPFv3 for OSPFv3 Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.
37 Policy-based Routing (PBR) Policy-based routing (PBR) allows you to apply routing policies to specific interfaces. To enable PBR, create a redirect list and apply it to the interface. After the redirect list is applied to the interface, all traffic passing through the interface is subject to the rules defined in the redirect list. PBR is supported by the Dell Networking Operating System (OS).
ip redirect-group Apply a redirect list (policy-based routing) on an interface. You can apply multiple redirect lists to an interface by entering this command multiple times. S6000 Syntax ip redirect-group redirect-list-name To remove a redirect list from an interface, use the no ip redirect-group name command. Parameters redirect-list-name Enter the name of a configured redirect list. Defaults none Command Modes INTERFACE (conf-if-vl-) Command History Usage Information Version Description 9.
Parameters redirect-list-name Defaults None Command Modes CONFIGURATION Command History Enter the name of a redirect list. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Introduced on the S4810, S4820T, S6000, and Z9000. 8.4.2.1 Introduced on the C-Series and S-Series. 8.4.2.0 Introduced on the E-Series Tera Scale. 7.7.1.0 Introduced on the E-Series ExaScale. permit Configure a permit rule.
operator Defaults none Command Modes REDIRECT-LIST Command History • ack = acknowledgement • fin = finish (no more data from the user) • psh = push function • rst = reset the connection • syn = synchronize sequence number • urg = urgent field (OPTIONAL) For TCP and UDP parameters only.
ip-address Enter the IP address of the forwarding router. slot/port Enter the keyword slot / port followed by the slot/port information. tunnel Enter the keyword tunnel to configure the tunnel setting. tunnel-id Enter the keyword tunnel-id to redirect the traffic. track Enter the keyword track to enable the tracking. track Enter the keyword track to track object-id. ip-protocol-number Enter a number from 0 to 255 for the protocol identified in the IP protocol header.
Version Description 9.7(0.0) Added support for the track-id on the S4810, S4820T, S6000, and Z9000. 9.4(0.0) Introduced on the S4810, S4820T, S6000, and Z9000. 8.4.2.1 Introduced on the C-Series and S-Series. 8.4.2.0 Introduced on the E-Series Tera Scale. 7.7.1.0 Introduced on the E-Series ExaScale. seq Configure a filter with an assigned sequence number for the redirect list.
host ip-address Enter the keyword host then the IP address to specify a host IP address. destination Enter the IP address of the network or host to which the packets are sent.
show cam pbr Display the PBR CAM content. S6000 Syntax show cam pbr {[interface interface] | stack—unit slot-number port-set number]} [summ Parameters interface interface Enter the keyword interface then the name of the interface. stack–unit number Enter the keyword stack-unit then the slot number. port-set number Enter the keywords port-set then the port-pipe number. summary Enter the keyword summary to view only the total number of CAM entries.
Parameters Command Modes Command History Example redirect-list-name • EXEC • EXEC Privilege Enter the name of a configured Redirect list. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Introduced on the S4810, S4820T, S6000, and Z9000. Dell#show ip redirect-list explicit_tunnel IP redirect-list explicit_tunnel: Defined as: seq 5 redirect tunnel 1 track 1 tcp 155.55.2.0/24 222.22.2.
38 PIM-Sparse Mode (PIM-SM) The protocol-independent multicast (PIM) commands are supported by the Dell Networking operating software on the platform. IPv4 PIM-Sparse Mode Commands The following describes the IPv4 PIM-sparse mode (PIM-SM) commands. clear ip pim rp-mapping The bootstrap router (BSR) feature uses this command to remove all or particular rendezvous point (RP) advertisement.
Usage Information This command re-applies the RP mapping logic for all the groups learnt by the node. Any stale information corresponding to the existing mapping configuration is updated. As a result, the existing BSR cache and the *,G's are deleted only if these entries are stale. clear ip pim tib Clear PIM tree information from the PIM database.
debug ip pim View IP PIM debugging messages. S6000 Syntax debug ip pim [vrf vrf-name] [bsr | events | group | packet [in | out] | register | state | timer [assert | hello | joinprune | register]] To disable PIM debugging, use the no debug ip pim [vrf vrf-name] command or use the undebug allto disable all debugging command. Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to view IP PIM debugging messages corresponding to that VRF.
Version Description 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.12.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the S-Series. ip pim bsr-border Define the border of PIM domain by filtering inbound and outbound PIM-BSR messages per interface. Syntax ip pim bsr-border To return to the default value, use the no ip pim bsr-border command.
Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to configure the PIM router on a VRF. interface Enter the following keywords and slot/port or number information: • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383. • For a Port Channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
Defaults 1 Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Version Description 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the C-Series for the port-channels and the S-Series. 7.7.1.0 Introduced on the E-Series. Example Dell(conf)# ip access-list extended iptv-channels Dell(config-ext-nacl)# permit ip 10.1.2.3/24 225.1.1.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the C-Series and S-Series. 7.6.1.0 Introduced on the E-Series. Do not enter this command before creating the access-list. ip pim query-interval Change the frequency of PIM Router-Query messages. Syntax ip pim query-interval seconds To return to the default value, use the no ip pim query-interval seconds command.
To return to the default, use the no ip pim [vrf vrf-name] register-filter access-list command. Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF. NOTE: Applies to specific VRF if input is provided, else applies to Default VRF. access-list Enter the name of an extended access list. Maximum 16 characters. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific.
group-address group-address mask Enter the keywords group-address then a group-address mask, in dotted decimal format (/xx), to assign that group address to the RP. override Enter the keyword override to override the BSR updates with static RP. The override takes effect immediately during enable/disable. NOTE: This option is applicable to multicast group range. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific.
priority • For a Port Channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a VLAN, enter the keyword vlan then a number from 1 to 4094. (OPTIONAL) Enter the priority used in Bootstrap election process. The range is zero (0) to 255.
Usage Information Version Description 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the C-Series for the port-channels and the S-Series. The interface must be enabled (the no shutdown command) and not have the switchport command configured.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the C-Series for the port-channels and the S-Series. 7.7.1.1 Introduced This command configures an expiration timer for all S.G entries, unless they are assigned to an Extended ACL.
Usage Information Dell Networking OS supports standard access lists for the SSM range. You cannot use extended ACLs for configuring the SSM range. If you configure an extended ACL and then used in the ip pim ssm-range {access list name} configuration, an error is reported. However, if you configure ip pim ssm-range {access list name} first and then you configure the ACL as an Extended ACL, an error is not reported and the ACL is not applied to the SSM range.
Usage Information Version Description 8.1.1.0 Introduced on the E-Series ExaScale. This command is applicable to last hop routers on the shared tree towards the rendezvous point (RP). show ip pim bsr-router View information on the Bootstrap router. S6000 Syntax show ip pim [vrf vrf-name] bsr-router Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to configure this setting on VRF.
show ip pim interface View information on the interfaces with IP PIM enabled. S6000 Syntax Parameters show ip pim [vrf vrf-name] interface vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to configure this setting on this VRF. NOTE: Applies to specific VRF if input is provided, else applies to Default VRF. Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific.
Field Description DR Prio Displays the Designated Router priority value configured on the interface (use the ip pim dr-priority command). DR Displays the IP address of the Designated Router for that interface. The show ip pim interface command does not display information corresponding to the loop-back interfaces. Example Dell#show ip pim interface Address Interface Ver/ Mode 165.87.34.5 Te 1/10 v2/S 10.1.1.2 Vl 10 v2/S 20.1.1.5 Vl 20 v2/S 165.87.31.
Field Description Neighbor address Displays the IP address of the PIM neighbor. Interface List the interface type, with either slot/port information or ID (VLAN or Port Channel), on which the PIM neighbor was found. Uptime/expires Displays the amount of time the neighbor has been up then the amount of time until the neighbor is removed from the multicast routing table (that is, until the neighbor hold time expires). Ver Displays the PIM version number.
Version Description 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the S-Series. Example Dell#show ip pim rp Group RP 224.2.197.115 165.87.20.4 224.2.217.146 165.87.20.4 224.3.3.3 165.87.20.4 225.1.2.1 165.87.20.4 225.1.2.2 165.87.20.4 229.1.2.1 165.87.20.4 229.1.2.2 165.87.20.
Exmaple Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.1 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. 7.5.1.0 Introduced on the E-Series. Group Address / MaskLen show ip pim summary View information about PIM-SM operation.
Example Dell# show ip pim summary PIM TIB version 495 Uptime 22:44:52 Entries in PIM-TIB/MFC : 2/2 Active Modes : PIM-SNOOPING Interface 1 0 3 summary: active PIM interface passive PIM interfaces active PIM neighbors TIB summary: 1/1 (*,G) entries in PIM-TIB/MFC 1/1 (S,G) entries in PIM-TIB/MFC 0/0 (S,G,Rpt) entries in PIM-TIB/MFC 0 0 0 0 PIM nexthops RPs sources Register states Message summary: 2582/2583 Joins sent/received 5/0 Prunes sent/received 0/0 Candidate-RP advertisements sent/received 0/0 BSR
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.
Example Dell#do show ip pim tib PIM Multicast Routing Table Flags: D - Dense, S - Sparse, C - Connected, L - Local, P - Pruned, R - RP-bit set, F - Register flag, T - SPT-bit set, J - Join SPT, M - MSDP created entry, A - Candidate for MSDP Advertisement K - Ack-Pending State Timers: Uptime/Expires Interface state: Interface, next-Hop, State/Mode (*, 225.1.1.1), uptime 00:40:16, expires 00:00:00, RP 20.40.4.4, flags: SCJ Incoming interface: Vlan 2007, RPF neighbor 20.30.124.
39 Port Monitoring The port monitoring feature allows you to monitor network traffic by forwarding a copy of each incoming or outgoing packet from one port to another port. Important Points to Remember • Port monitoring is supported on physical ports and logical interfaces, such as port channels and virtual local area networks (VLANs). • The monitoring (destination, “MG”) and monitored (source, “MD”) ports must be on the same switch.
Related Commands Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.7.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-7.7.1.0 Introduced on the E-Series. monitor session — enables a monitoring session. monitor multicast-queue Configure monitor QoS multicast queue ID.
monitor session Create a session for monitoring traffic with port monitoring. Syntax monitor session session-ID [type { rpm | erpm [set ip dscp dscp_value | set ip ttl ttl_value]}] [drop] To delete a session, use the no monitor session session-ID command. To delete all monitor sessions, use the no monitor session all command. Parameters session-ID Enter a session identification number. The range is from 0 to 65535.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. Usage Information The monitor command is saved in the running configuration at Monitor Session mode level and can be restored after a chassis reload. Example Dell#show monitor session SessID Source Destination Dest IP DSCP TTL ------ -------------------------- --0 Te 1/12 remote-ip 7.1.1.2 0 255 0 Po 1 remote-ip 7.1.1.2 0 255 1 Vl 11 remote-ip 3.1.1.
show config Display the current monitor session configuration. Syntax show config Defaults none Command Modes MONITOR SESSION (conf-mon-sess-session-ID) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.0.0 Added support for the RPM / ERPM. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.7.1.
• For a VLAN interface enter the keyword VLAN followed by a number from 1 to 4094. • For a port channel interface, enter the keywords port-channel then a number. range Enter the keyword range to specify the list of interfaces. any Enter the keyword any to specify all interfaces. NOTE: This option is applicable only with drop monitor session. destination interface direction {rx | tx | both} Enter the keyword destination to specify the destination interface.
Example Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.1.1.0 Introduced on the E-Series ExaScale. 7.7.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series.
40 Private VLAN (PVLAN) The private VLAN (PVLAN) feature of the Dell Networking operating software is supported on the S6000 platforms. Private VLANs extend the Dell Networking OS security suite by providing Layer 2 isolation between ports within the same private VLAN. A private VLAN partitions a traditional VLAN into subdomains identified by a primary and secondary VLAN pair. The Dell Networking OS private VLAN implementation is based on RFC 3069. For more information, refer to the following commands.
– A trunk port in a PVLAN is always tagged. – A trunk port in Tagged mode carries primary or secondary VLAN traffic. The tag on the packet helps identify the VLAN to which the packet belongs. – A trunk port can also belong to a regular VLAN (non-private VLAN). ip local-proxy-arp Enable/disable Layer 3 communication between secondary VLANs in a private VLAN.
private-vlan mode Set PVLAN mode of the selected VLAN to community, isolated, or primary. S6000 Syntax [no] private-vlan mode {community | isolated | primary} To remove the PVLAN configuration, use the no private-vlan mode {community | isolated | primary} command syntax. Parameters community Enter the keyword community to set the VLAN as a community VLAN. isolated Enter the keyword isolated to configure the VLAN as an isolated VLAN.
private-vlan mapping secondary-vlan Map secondary VLANs to the selected primary VLAN. S6000 Syntax [no] private-vlan mapping secondary-vlan vlan-list To remove specific secondary VLANs from the configuration, use the no private-vlan mapping secondary-vlan vlan-list command syntax. Parameters vlan-list Enter the list of secondary VLANs to associate with the selected primary VLAN. The list can be in comma-delimited or hyphenated-range format, following the convention for the range input.
switchport mode private-vlan Set PVLAN mode of the selected port. S6000 Syntax [no] switchport mode private-vlan {host | promiscuous | trunk} To remove PVLAN mode from the selected port, use the no switchport mode private-vlan command. Parameters host Enter the keyword host to configure the selected port or port channel as an isolated interface in a PVLAN. promiscuous Enter the keyword promiscuous to configure the selected port or port channel as an promiscuous interface.
Related Commands private-vlan mode — sets the mode of the selected VLAN to community, isolated, or primary. private-vlan mapping secondary-vlan — sets the mode of the selected VLAN to primary and then associates the secondary VLANs to it.
41 Per-VLAN Spanning Tree Plus (PVST+) The Dell Networking operating software implementation of per-VLAN spanning tree plus (PVST+) is based on the IEEE 802.1w standard spanning tree protocol. Dell Networking OS supports PVST+ on the S6000 platform. NOTE: For easier command line entry, the plus (+) sign is not used at the command line. description Enter a description of the PVST+. S6000 Syntax description {description} To remove the description, use the no description {description} command.
disable Disable PVST+ globally. S6000 Syntax disable To enable PVST+, use the no disable command. Defaults Disabled. Command Modes CONFIGURATION (conf-pvst) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced. Dell(conf-pvst)#do show spanning-tree pvst vlan 5 brief VLAN 5 Executing IEEE compatible Spanning Tree Protocol Root ID Priority 32773, Address 0001.e832.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 8.3.1.0 Introduced.
• guard Defaults For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. (OPTIONAL) Enter the keyword guard to display the type of guard enabled on a PVST interface and the current port state. none Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Configured hello time 2, max age 20, forward delay 15 Interface Designated Name PortID Prio Cost Sts Cost Bridge ID PortID ---------------------------------------------------------Te 1/0 128.130 128 20000 FWD 20000 4096 0001.e801.6aa8 128.426 Te 1/1 128.131 128 20000 BLK 20000 4096 0001.e801.6aa8 128.427 Te 1/16 128.146 128 20000 FWD 20000 16384 0001.e805.e306 128.146 Te 1/17 128.147 128 20000 FWD 20000 16384 0001.e805.e306 128.
Edge port:no (default) port guard :none (default) Link type: point-to-point (auto) bpdu filter:disable (default) Bpdu guard :disable (default) Bpdus sent 152, received 27562 Interface Designated Name PortID Prio Cost Sts Cost Bridge ID PortID ----------------------------------------------------------Te 1/1 128.1223 128 20000 EDS 0 32768 0001.e800.a12b 128.
Enter the keyword bpduguard to disable the port when it receives a BPDU. shutdown-onviolation (OPTIONAL) Enter the keywords shutdown-on-violation to hardware disable an interface when a BPDU is received and the port is disabled. err-disable Enter the keywords err-disable to enable the port to be put into the errordisable state (EDS) if an error condition occurs. vlan vlan-range Enter the keyword vlan then the VLAN numbers. The range is from 1 to 4094.
Usage Information Version Description 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Added the optional Bridge Port Data Unit (BPDU) guard. 6.2.1.1 Introduced. The BPDU guard option prevents the port from participating in an active STP topology in case a BPDU appears on a port unintentionally, or is misconfigured, or is subject to a DOS attack. This option places the port into the Error Disable state if a BPDU appears, and a message is logged so that the administrator can take corrective action.
spanning-tree pvst err-disable Place ports in an Err-Disabled state if they receive a PVST+ BPDU when they are members an untagged VLAN. S6000 Syntax spanning-tree pvst err-disable cause invalid-pvst-bpdu Defaults Enabled; ports are placed in the Err-Disabled state if they receive a PVST+ BPDU when they are members of an untagged VLAN. Command Modes INTERFACE Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series.
Related Commands Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced. vlan forward-delay — changes the time interval before Dell Networking OS transitions to the Forwarding state. vlan hello-time — change the time interval between BPDUs. vlan max-age — changes the time interval before PVST+ refreshes.
Related Commands Version Description 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced. vlan bridge-priority — sets the bridge-priority value. vlan hello-time — changes the time interval between BPDUs. vlan max-age — changes the time interval before PVST+ refreshes. show spanning-tree pvst — displays the PVST+ configuration. vlan hello-time Set the time interval between generation of PVST+ 7 BPDUs.
Related Commands Version Description 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced. vlan bridge-priority — sets the bridge-priority value. vlan forward-delay — changes the time interval before Dell Networking OS transitions to the forwarding state. vlan max-age — changes the time interval before PVST+ refreshes. show spanning-tree pvst — displays the PVST+ configuration.
Related Commands Version Description 6.2.1.1 Introduced. vlan bridge-priority — sets the bridge-priority value. vlan forward-delay — changes the time interval before Dell Networking OS transitions to the forwarding state. vlan hello-time — changes the time interval between BPDUs. show spanning-tree pvst — displays the PVST+ configuration.
42 Quality of Service (QoS) The Dell Networking operating software commands for quality of service (QoS) include traffic conditioning and congestion control. QoS commands are not universally supported on all Dell Networking Products. S6000 platform. This chapter contains the following sections: • Global Configuration Commands • Per-Port QoS Commands • Policy-Based QoS Commands Global Configuration Commands There is only one global configuration QoS command.
Version Description 8.3.1.0 Introduced. service-class bandwidth-percentage Specify a minimum bandwidth for queues. S6000 Syntax service-class bandwidth-percentage queue0 number queue1 number queue2 number queue3 number queue4 number queue5 number queue6 number queue7 number service-class bandwidth-percentage queue0 number queue1 number queue2 number queue3 number Parameters number Enter the bandwidth-weight, as a percentage. The range is from 1 to 100.
• Queue : 2 0 1 3 4 5 6 7 Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
strict-priority queue Configure a unicast queue as a strict-priority (SP) queue. S6000 Syntax strict-priority queue unicast number Parameters unicast number Enter the keyword unicast then the queue number. The range is from 1 to 3. Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
2 1 3 3 4 4 5 5 6 6 7 7 Defaults none Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. Version The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
burst-KB (OPTIONAL) Enter the burst size in KB. The range is from 16 to 200000. The default is 50. peak peak-rate (OPTIONAL) Enter the keyword peak then a number to specify the peak rate in Mbps. The range is from 0 to 40000. vlan vlan-id (OPTIONAL) Enter the keyword vlan then a VLAN ID to police traffic to those specific VLANs. The range is from 1 to 4094. Defaults Granularity for commited-rate and peak-rate is Mbps unless you use the kbps option.
Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810.
• Command History CONFIGURATION This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.1.9.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 6.2.1.1 Introduced on the E-Series.
buffer-stats-snapshot no disable class-map Create/access a class map. Class maps differentiate traffic so that you can apply separate quality-of-service policies to each class. S6000 Syntax class-map {match-all | match-any} class-map-name [cpu-qos] [layer2] Parameters match-all Determines how packets are evaluated when multiple match criteria exist. Enter the keywords match-all to determine that the packets must meet all the match criteria in order to be a member of the class.
Related Commands ip access-list extended — configures an extended IP ACL. ip access-list standard — configures a standard IP ACL. match ip access-group — configures the match criteria based on the access control list (ACL). match ip precedence — identifies the IP precedence values as match criteria. match ip dscp — configures the match criteria based on the DSCP value. match mac access-group — configures a match criterion for a class map based on the contents of the designated MAC ACL.
Related Commands Version Description 8.3.7.0 Introduced on the S4810. show qos statistics — displays the QoS statistics. description Add a description to the selected policy map or QoS policy. S6000 Syntax description {description} To remove the description, use the no description {description} command. Parameters description Enter a description to identify the policies (80 characters maximum).
match ip access-group Configure match criteria for a class map, based on the access control list (ACL). NOTE: IPv6 class-maps and IP-any class-maps do not match. This condition is true for IPv6 and IP-any class-maps on both ACLs as well as VLANs. S6000 Syntax match ip access-group access-group-name [set-ip-dscp value | set-color value] To remove ACL match criteria from a class map, use the no match ip access-group accessgroup-name [set-ip-dscp value | set-color value] command.
match ip dscp Use a differentiated services code point (DSCP) value as a match criteria. S6000 Syntax match {ip | ipv6 | ip-any} dscp dscp-list [set-ip-dscp value] To remove a DSCP value as a match criteria, use the no match {ip | ipv6 | ip-any} dscp dscp-list [[multicast] set-ip-dscp value] command. Parameters ip Enter the keyword ip to support IPv4 traffic. ipv6 Enter the keyword ipv6 to support IPv6 traffic. ip-any Enter the keyword ip-any to support IPv4 and IPv6 traffic.
match ip precedence Use IP precedence values as a match criteria. S6000 Syntax match {ip | ipv6 | ip-any} precedence ip-precedence-list [set-ip-dscp value] To remove IP precedence as a match criteria, use the no match {ip | ipv6 | ip-any} precedence ip-precedence-list [[multicast] set-ip-dscp value] command. Parameters ip Enter the keyword ip to support IPv4 traffic. ipv6 Enter the keyword ipv6 to support IPv6 traffic. ip-any Enter the keyword ip-any to support IPv4 and IPv6 traffic.
NOTE: Only one of the IP precedence values must be a successful match criterion, not all of the specified IP precedence values must match. Related Commands class-map — identifies the class map. match mac access-group Configure a match criterion for a class map, based on the contents of the designated MAC ACL. S6000 Syntax match mac access-group {mac-acl-name} Parameters mac-acl-name Enter a MAC ACL name. Its contents is used as the match criteria in the class map.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. Usage Information To access this command, enter the class-map command. After the class map is identified, you can configure the match criteria. Related Commands class-map — identifies the class map.
policy-aggregate Allow an aggregate method of configuring per-port QoS via policy maps. An aggregate QoS policy is part of the policy map (output) applied on an interface. S6000 Syntax policy-aggregate qos-policy-name To remove a policy aggregate configuration, use the no policy-aggregate qos-policy-name command. Parameters qos-policy-name Enter the name of the policy map in character format (32 characters maximum).
layer2 (OPTIONAL) Enter the keyword layer2 to specify a Layer 2 Class Map. The default is Layer 3. Defaults Layer 3 Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. Usage Information To assign traffic to different flows using QoS policy, use the Output Policy map. This command enables Policy-Map-Output Configuration mode (conf-policy-map-out). Related Commands service-queue — assigns a class map and QoS policy to different queues. policy-aggregate — allows an aggregate method of configuring per-port QoS using policy maps.
When changing a Service-Queue configuration in a QoS policy map, all QoS rules are deleted and re-added automatically to ensure that the order of the rules is maintained. As a result, the Matched Packets value shown in the show qos statistics command is reset. Related Commands rate police — incoming traffic policing function. qos-policy-output Create a QoS output policy.
Parameters kbps Enter the keyword kbps to specify the rate limit in Kilobits per second (Kbps). Make the following value a multiple of 64. The range is from 0 to 40000000. The default granularity is Megabits per second (Mbps). committed-rate Enter the bandwidth in Mbps. The range is from 0 to 40000. burst-KB (OPTIONAL) Enter the burst size in KB. The range is from 16 to 200000. The default is 100. peak peak-rate (OPTIONAL) Enter the keyword peak then a number to specify the peak rate in Mbps.
Defaults Burst size is 10KB. Granularity for rate is Mbps unless you use the kbps option. Command Modes QOS-POLICY-OUT Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. You can attach a single policy-map to one or more interfaces to specify the service-policy for those interfaces. A policy map attached to an interface can be modified. NOTE: The service-policy commands are not allowed on a port channel.
service-queue Assign a class map and QoS policy to different queues. S6000 Syntax service-queue queue-id [class-map class-map-name] [qos-policy qos-policyname] To remove the queue assignment, use the no service-queue queue-id [class-map classmap-name] [qos-policy qos-policy-name] command. Parameters queue-id Enter the value used to identify a queue. The range is from 0 to 7.
set Mark outgoing traffic with a differentiated service code point (DSCP) or dot1p value. S6000 Syntax set {ip-dscp value | mac-dot1p value} Parameters ip-dscp value (OPTIONAL) Enter the keywords ip-dscp then the IP DSCP value. The range is from 0 to 63. mac-dot1p value Enter the keywords mac-dot1p then the dot1p value. The range is from 0 to 7. Defaults none Command Modes CONFIGURATION (conf-qos-policy-in) Command History This guide is platform-specific.
Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. Dell#show qos class-map Class-map match-any CM Match ip access-group ACL Related Commands class-map — identifies the class map. show qos policy-map View the QoS policy map information.
Example (IPv4) Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810.
qos-policy-input qos-policy-name Defaults Command Modes Command History Enter the keyword qos-policy-input then the QoS policy name. none • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.
Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. Dell#show qos policy-map-output Policy-map-output PolicyMapOutput Aggregate Qos-policy-name AggPolicyOut Queue# Qos-policy-name 0 qosPolicyOutput Dell# show qos qos-policy-input View the input QoS policy details.
show qos qos-policy-output View the output QoS policy details. S6000 Syntax Parameters Defaults Command Modes Command History show qos qos-policy-output [qos-policy-name] qos-policy-name Enter the QoS policy name. none • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
wred-profile interface interface Defaults Enter the keywords wred-profile and optionally one of the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810.
The following table describes the mapping between the threshold weight of the shared buffer on the queue and the percentage of available shared buffer that is used by the queue for each of the corresponding threshold weights of the shared buffer: Example shared-threshold-weight on the queue % of available shared buffer that can be consumed by the queue. 0 No dynamic sharing; shared buffer = 0. 1 0.77% 2 1.54% 3 3.03% 4 5.88% 5 11.11% 6 20% 7 33.33% 8 50% 9 66.67% 10 80% 11 88.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810.
ports) 0 0 1 1 13 Dell# | | 0 1 0 1 | L2ACL L2ACL L2ACL L2ACL … … … L2ACL 1 |per Port |(Allowed 500 100 1000 0 200 200 200 200 Allowed (2) Exception Allowed (5) Exception 400 200 Allowed (2) threshold Specify the minimum and maximum threshold values for the configured WRED profiles. S6000 Syntax threshold min number max number max-drop-probability To remove the threshold values, use the no threshold min number max number command.
Related Commands Pre-Defined WRED Profile Name Minimum Threshold Maximum Threshold Maximum Drop Rate wred_drop 0 0 100 wred_teng_y 594 5941 100 wred_teng_g 594 5941 50 wred_fortyg_y 594 5941 50 wred_fortyg_g 594 5941 25 wred-profile — creates a WRED profile. trust Specify dynamic classification (DSCP) or dot1p to trust. S6000 Syntax Parameters trust {diffserv [fallback]| dot1p [fallback]} diffserv Enter the keyword diffserv to specify trust of DSCP markings.
DSCP/CP hex Range (XXX) DSCP Definition Traditional IP Precedence S6000 Internal Queue ID S-Series Internal Queue ID DSCP/CP Decimal 111XXX Network Control 7 3 48–63 110XXX Internetwork Control 6 3 48–63 101XXX EF (Expedited Forwarding) CRITIC/ECP 5 2 32–47 100XXX AF4 (Assured Forwarding) Flash Override 4 2 32–47 011XXX AF3 Flash 3 1 16–31 010XXX AF2 Immediate 2 1 16–31 001XXX AF1 Priority 1 0 0–15 000XXX BE (Best Effort) Best Effort 0 0 0–15 wred Designat
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. Usage Information To assign drop precedence to green or yellow traffic, use this command. If there is no honoring enabled on the input, all the traffic defaults to green drop precedence. Related Commands wred-profile — creates a WRED profile and name that profile. trust — defines the dynamic classification to trust DSCP.
• If neither endpoint is ECN-capable, the packet may be dropped based on the WRED drop probability. This behavior is the identical treatment that a packet receives when WRED is enabled without ECN configured on the router. When you enable wred ecn, and the number of packets in the queue is above the maximum threshold, packets are dropped based on the drop probability. This behavior is the identical treatment a packet receives when WRED is enabled without ECN configured on the router.
Parameters wred-profile-name Enter your WRED profile name in character format (32 character maximum). Or use one of the pre-defined WRED profile names. You can configure up to 26 WRED profiles plus the five pre-defined profiles, for a total of 31 WRED profiles. Pre-defined Profiles: wred_drop, wred-ge_y, wred_ge_g, wred_teng_y, wred_teng_g. Defaults The five pre-defined WRED profiles. When you configure a new profile, the minimum and maximum threshold defaults to predefined wred_ge_g values.
268000000 for pps. The range is from 0 to 40000 for Mbps (which is the default measure for rate limits if you do not explicitly configure Kbps or pps) burst-KB (OPTIONAL) Enter the committed burst size in KB. The range is from 0 to 10000. The default is 50 KB. The default peak burst is regarded as the same value as the configured committed burst size. Packets (OPTIONAL) Enter the committed burst size as a count of packets. The range is from 1 to 1073000. The default is 50 packets.
parameters to be either in bytes or packets measure for each queue. The rate and burst parameters for both minimum and maximum settings for a queue can be either in packets or bytes. You cannot configure some of rate shaping attributes to be in bytes measure and the remaining rate shaping attributes to be in packets measure; all the rate shaping attributes must contain the same metric or unit of measure.
Usage Information You can configure only service pools 0 and 1 because the Dell Networking OS uses only these two service pools. The pool, service0, is used for lossy queues and the pool, service1, is used for lossless (PFC) queues in all the platforms. You can configure the weight for the WRED average queue size for service1 on the S6000 Switch, which is the only platform in which PFC is supported for this service pool. On the Z9000 Switch, only service0 can be configured because it does not support PFC.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5.0.0 Introduced on the Z9000, S6000, S4820T, S4810, and MXL.
Version Description 9.5.0.0 Introduced on the Z9000, S6000, S4820T, S4810, and MXL. Usage Information A color map outlines the codepoint mappings to the appropriate color mapping (green, yellow, red) for the traffic. The system uses this information use to handle the traffic on the interface based on the traffic priority and places it into the appropriate shaping queue. You cannot delete a DSCP color map when it is configured on an interface.
qos dscp-color-map— configures the DSCP color map. show qos dscp-color-policy Display DSCP color policy configuration for one or all interfaces. Syntax Parameters show qos dscp-color-policy {summary [interface] | detail {interface}} summary Enter the summary keyword to display summary information about a color policy on one or more interfaces. Detail Enter the detail keyword to display detailed information about a color policy on one or more interfaces.
show qos dscp-color-map Display the DSCP color map for one or all interfaces. Syntax show qos dscp-color-map map-name Parameters map-name Enter the name of the color map. Defaults None Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.
43 Routing Information Protocol (RIP) Routing information protocol (RIP) is a distance vector routing protocol. The Dell Networking operating software supports both RIP version 1 (RIPv1) and RIP version 2 (RIPv2) on the S6000 platform. The Dell Networking OS implementation of RIP is based on IETF RFCs 2453 and RFC 1058. For more information about configuring RIP, refer to the Dell Networking OS Configuration Guide.
clear ip rip Update all the RIP routes in the Dell Networking OS routing table. S6000 Syntax clear ip rip Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.
database (OPTIONAL) Enter the keyword database to display messages when there is a change to the RIP database. events (OPTIONAL) Enter the keyword events to debug only RIP protocol changes. trigger (OPTIONAL) Enter the keyword trigger to debug only RIP trigger extensions. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series.
Version Description 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. pre- 6.2.1.1 Introduced on the E-Series. Usage Information This command ensures that route information being redistributed is converted to the same metric value. Related Commands redistribute — allows you to redistribute routes learned by other methods. description Enter a description of the RIP routing protocol.
distance Assign a weight (for prioritization) to all routes in the RIP routing table or to a specific route. Lower weights (“administrative distance”) are preferred. S6000 Syntax distance weight [ip-address mask [prefix-name]] To return to the default values, use the no distance weight [ip-address mask] command. Parameters weight Enter a number from 1 to 255 for the weight (for prioritization). The default is 120. ip-address (OPTIONAL) Enter the IP address, in dotted decimal format (A.B.C.
To delete the filter, use the no distribute-list prefix-list-name in command. Parameters prefix-list-name Enter the name of a configured prefix list. interface (OPTIONAL) Identifies the interface type slot/port as one of the following: • For a Port Channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
To delete the filter, use the no distribute-list prefix-list-name out command. Parameters prefix-list-name Enter the name of a configured prefix list. interface (OPTIONAL) Identifies the interface type slot/port as one of the following: • For a Port Channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
ip poison-reverse Set the prefix of the RIP routing updates to the RIP infinity value. S6000 Syntax ip poison-reverse To disable poison reverse, use the no ip poison-reverse command. Defaults Disabled. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.6.1.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. pre- 6.2.1.1 Introduced on the E-Series. Usage Information To enable the interface to send both version of RIP packets, use the ip rip send version 1 2 command.
Related Commands Version Description pre- 6.2.1.1 Introduced on the E-Series. ip poison-reverse — sets the prefix for RIP routing updates. maximum-paths Set RIP to forward packets over multiple paths. S6000 Syntax maximum-paths number To return to the default values, use the no maximum-paths commands. Parameters number Enter the number of paths. The range is from 1 to 16. The default is 4 paths. Defaults 4 Command Modes ROUTER RIP Command History This guide is platform-specific.
To delete a neighbor setting, use the no neighbor ip-address command. Parameters ip-address Enter the IP address, in dotted decimal format, of a router with which to exchange information. Defaults Not configured. Command Modes ROUTER RIP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series.
Defaults Not configured. Command Modes ROUTER RIP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. pre- 6.2.1.1 Introduced on the E-Series. This command is intended for low-speed interfaces. passive-interface Suppress routing updates on a specified interface.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. pre- 6.2.1.1 Introduced on the E-Series. Usage Information Although the passive interface does not send or receive routing updates, the network on that interface still includes in RIP updates sent using other interfaces.
Version Description 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. pre- 6.2.1.1 Introduced on the E-Series. Usage Information To redistribute the default route (0.0.0.0/0), configure the default-information originate command. Related Commands default-information originate — generates a default route for RIP traffic. redistribute isis Redistribute routing information from an IS-IS instance.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. pre- 6.2.1.1 Introduced on the E-Series. redistribute ospf Redistribute routing information from an OSPF process. S6000 Syntax redistribute ospf process-id [match external {1 | 2} | match internal | metric metric-value] [route-map map-name] To disable redistribution, use the no redistribute ospf process-id [match external {1 | 2} | match internal | metric metric-value] [route-map map-name] command.
Version Description 7.6.1.0 Introduced on the C-Series. pre- 6.2.1.1 Introduced on the E-Series. router rip To configure and enable RIP, enter ROUTER RIP mode. S6000 Syntax router rip To disable RIP, use the no router rip command. Defaults Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
show config Display the changes you made to the RIP configuration. The default values are not shown. S6000 Syntax show config Command Modes ROUTER RIP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Example 1150 Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.
show running-config rip Display the current RIP configuration. S6000 Syntax show running-config rip Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.
Defaults invalid Enter the number of seconds to specify the time interval before routing updates are declared invalid or expired. The invalid value should be at least three times the update timer value. The range is from zero (0) to 4294967295. The default is 180 seconds. holddown Enter the number of seconds to specify a time interval during which the route is marked as unreachable but still sending RIP packets. The holddown value should be at least three times the update timer value.
To return to the default version setting, use the no version command. Parameters 1 Enter the keyword 1 to specify RIP version 1. 2 Enter the keyword 2 to specify RIP version 2. Defaults The Dell Networking OS sends RIPv1 and receives RIPv1 and RIPv2. Command Modes ROUTER RIP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
44 Remote Monitoring (RMON) The Dell Networking operating software remote monitoring (RMON) is implemented on the S6000 platform. Dell Networking OS RMON is based on IEEE standards, providing both 32-bit and 64-bit monitoring and long-term statistics collection.
interval Time, in seconds, the alarm monitors the MIB variables; this is the alarmSampleType in the RMON alarm table. The range is from 5 to 3600 seconds. delta Enter the keyword delta to test the change between MIB variables. This is the alarmSampleType in the RMON alarm table. absolute Enter the keyword absolute to test each MIB variable directly. This is the alarmSampleType in the RMON alarm table.
rmon collection history Enable the RMON MIB history group of statistics collection on an interface. S6000 Syntax rmon collection history {controlEntry integer} [owner name] [buckets number] [interval seconds] To remove a specified RMON history group of statistics collection, use the no rmon collection history {controlEntry integer} command. Parameters controlEntry integer Enter the keyword controlEntry to specify the RMON group of statistics using a value.
rmon collection statistics Enable RMON MIB statistics collection on an interface. S6000 Syntax rmon collection statistics {controlEntry integer} [owner name] To remove RMON MIB statistics collection on an interface, use the no rmon collection statistics {controlEntry integer} command. Parameters controlEntry integer Enter the keyword controlEntry to specify the RMON group of statistics using a value. Then enter an integer value from 1 to 65535 that identifies the RMON Statistic Table.
Parameters number Assign an event number in integer format. The range is from 1 to 65535. You must ensure that the value you enter is unique in the RMON event table. log (OPTIONAL) Enter the keyword log to generate an RMON event log. This option sets the eventType to either log or log-and-snmptrap in the RMON event table. The default is None. trap community (OPTIONAL) Enter the keyword trap followed by the SNMP community string to generate SNMP traps for an RMON event entry.
variable The MIB object to monitor. The variable must be in the SNMP OID format; for example, 1.3.6.1.2.1.1.3 The object type must be a 64-bit integer. interval Time, in seconds, the alarm monitors the MIB variables; this is the alarmSampleType in the RMON alarm table. The range is from 5 to 3600 seconds. delta Enter the keyword delta to test the change between MIB variables. This is the alarmSampleType in the RMON alarm table. absolute Enter the keyword absolute to test each MIB variable directly.
show rmon Display the RMON running status including the memory usage. S6000 Syntax show rmon Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
show rmon events Display the contents of the RMON event table. S6000 Syntax show rmon events [index] [brief] Parameters index (OPTIONAL) Enter the table index number to display just that entry. brief (OPTIONAL) Enter the keyword brief to display the RMON event table in an easy-to-read format. Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
event owner: event status: OK RMON event entry 114 description: event type: LOG and SNMP TRAP. event community: public event last time sent: none event owner: event status: OK Example (Brief) Dell#show rmon event brief index description -----------------------------1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 13 13 14 14 15 15 16 16 17 17 18 18 19 19 20 20 21 21 22 22 Dell# show rmon hc-alarm Display the contents of RMON High-Capacity alarm table.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series. Example (Index) Dell#show rmon hc-alarm 1 RMON high-capacity alarm entry 2 object: 1.3.6.1.2.1.2.2.1.4.2099844 sample interval: 10 sample type: delta value.
Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
brief (OPTIONAL) Enter the keyword brief to display the RMON log table in an easyto-read format. Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
brief (OPTIONAL) Enter the keyword brief to display the RMON Ethernet statistics table in an easy-to-read format. Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example (Index) Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
HC 512-1023 bytes packets: 0 HC 1024-1518 bytes packets overflow: 0 HC 1024-1518 bytes packets: 0 Dell# Example (Brief) 1168 Dell#show rmon statistics br index ifIndex interface ---------------------------------------6001 100974631 TenGigabitEthernet 2/2 6002 100974631 TenGigabitEthernet 2/2 6003 101236775 TenGigabitEthernet 2/1 6004 101236775 TenGigabitEthernet 2/1 9001 134529054 TenGigabitEthernet 3/2 9002 134529054 TenGigabitEthernet 3/2 9003 134791198 TenGigabitEthernet 3/1 9004 134791198 TenGigabitEt
45 Rapid Spanning Tree Protocol (RSTP) The Dell Networking operating software implementation of rapid spanning tree protocol (RSTP) is based on the IEEE 802.1w standard spanning-tree protocol. The RSTP algorithm configures connectivity throughout a bridged local area network (LAN) that is comprised of LANs interconnected by bridges. Dell Networking OS supports RSTP. bridge-priority Set the bridge priority for RSTP.
debug spanning-tree rstp Enable debugging of RSTP and view information on the protocol. Syntax debug spanning-tree rstp [all | bpdu interface {in | out} | events] To disable debugging, use the no debug spanning-tree rstp command. Parameters all (OPTIONAL) Enter the keyword all to debug all spanning tree operations. bpdu interface {in | out} (OPTIONAL) Enter the keyword bpdu to debug the bridge protocol data units.
description Enter a description of the rapid spanning tree. Syntax description {description} To remove the description, use the no description {description} command. Parameters description Enter a description to identify the rapid spanning tree (80 characters maximum). Defaults none Command Modes SPANNING TREE (The prompt is “config-rstp”.) Command History This guide is platform-specific.
Related Commands Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. protocol spanning-tree rstp — enters SPANNING TREE mode on the switch. forward-delay Configure the amount of time the interface waits in the Listening State and the Learning State before transitioning to the Forwarding State.
hello-time Set the time interval between the generation of the RSTP bridge protocol data units (BPDUs). Syntax hello-time [milli-second] seconds To return to the default value, use the no hello-time command. Parameters seconds Enter a number as the time interval between transmission of BPDUs. The range is from 1 to 10 seconds. The default is 2 seconds. milli-second Enter the keywords milli-second to configure a hello time on the order of milliseconds.
max-age To maintain configuration information before refreshing that information, set the time interval for the RSTP bridge. Syntax max-age seconds To return to the default values, use the no max-age command. Parameters max-age Enter a number of seconds the Dell Networking OS waits before refreshing configuration information. The range is from 6 to 40 seconds. The default is 20 seconds.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. Usage Information RSTP is not enabled when you enter RSTP mode.
no disable bridge-priority 16384 show spanning-tree rstp Display the RSTP configuration. Syntax show spanning-tree rstp [brief] [guard] Parameters Command Modes Command History Usage Information Example (Brief) 1176 brief (OPTIONAL) Enter the keyword brief to view a synopsis of the RSTP configuration information. guard (OPTIONAL) Enter the keyword guard to display the type of guard enabled on an RSTP interface and the current port state. • EXEC • EXEC Privilege Version Description 9.7(0.
Root ID Priority 8192, Address 0001.e805.e306 Root Bridge hello time 4, max age 20, forward delay 15 Bridge ID Priority 16384, Address 0001.e801.6aa8 Configured hello time 2, max age 20, forward delay 15 Interface Designated Name PortID Prio Cost Sts Cost Bridge ID PortID ---------- ------- --- ------- -------------------- -------Te 4/2 128.418 128 20000 FWD 20000 16384 0001.e801.6aa8 128.418 Te 4/1 128.419 128 20000 FWD 20000 16384 0001.e801.6aa8 128.419 Te 4/8 128.426 128 20000 FWD 20000 8192 0001.e805.
spanning-tree rstp Configure an RSTP interface with one of these settings: port cost, edge port with optional bridge port data unit (BPDU) guard, port priority, loop guard, or root guard. Syntax spanning-tree rstp {cost port-cost | edge-port [bpduguard [shutdown-onviolation]] | priority priority | {loopguard | rootguard}} Parameters cost port-cost Enter the keyword cost then the port cost value. The range is from 1 to 200000.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.4.2.1 Added support for the optional guard keyword on the C-Series, S-Series, and ESeries TeraScale. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced the hardware shutdown-on-violation options. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Added the optional bridge port data unit (BPDU) guard. 6.2.1.1 Introduced on the E-Series.
tc-flush-standard Enable the MAC address flushing after receiving every topology change notification. Syntax tc-flush-standard To disable, use the no tc-flush-standard command. Defaults Disabled Command Modes CONFIGURATION (conf-rstp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
46 Security The commands in this chapter are available on Dell Networking OS. This chapter contains various types of security commands offered in the Dell Networking operating software. The commands are listed in the following sections: • AAA Accounting Commands • Authorization and Privilege Commands • Authentication and Password Commands • RADIUS Commands • TACACS+ Commands • Port Authentication (802.
commands {level | role role-name Enter the keyword command then a privilege level for accounting of commands executed at that privilege level or enter the keyword role then the role name for accounting of commands executed by a user with that user role. name | default Enter one of the following: • For name, enter a user-defined name of a list of accounting methods. • For default, the default accounting methods used.
Dell(conf)# aaa accounting command role secaadmin default start-stop tacacs + Related Commands enable password — changes the password for the enable command. login authentication — enables AAA login authentication on the terminal lines. password — creates a password. tacacs-server host — specifies a TACACS+ server host. aaa accounting suppress Prevent the generation of accounting records of users with the user name value of NULL.
accounting Apply an accounting method list to terminal lines. S6000 Syntax accounting {exec | commands {level | role role-name} method-list Parameters exec Enter the keyword exec to apply an EXEC level accounting method list. commands {level | role role-name} Enter the keywords commands level to apply an EXEC and CONFIGURATION level accounting method list by enter the keyword role and then the role name for accounting of commands executed by a user with that user role.
Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4.(0.0) Introduced on the S-Series and Z-Series.
Example Dell#show accounting Active accounted actions on tty2, User admin Priv 1 Role Task ID 2, EXEC Accounting record, 00:02:03 Elapsed, service=shell Active accounted actions on tty3, User ad Priv 15 Role Task ID 7, EXEC Accounting record, 00:01:22 Elapsed, service=shell Active accounted actions on tty4, User ad Priv 15 Role Task ID 11, EXEC Accounting record, 00:00:35 Elapsed, service=shell Active accounted actions on tty5, User ad1 Priv 1 Role sysadmin Task ID 16, EXEC Accounting record, 00:00:04 Elap
Related Commands Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.3.1.0 Introduced on the E-Series. aaa authorization commands — sets the parameters that restrict (or permit) a user’s access to EXEC and CONFIGURATION level commands aaa authorization exec — sets the parameters that restrict (or permit) a user’s access to EXEC level commands.
Version Description 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Added support for RADIUS. aaa authorization config-commands Set parameters that restrict (or permit) a user’s access to EXEC level commands. Syntax aaa authorization config-commands Disable authorization checking for CONFIGURATION level commands using the no aaa authorization config-commands command.
local Use the authorization parameters on the system to perform authorization. tacacs+ Use the TACACS+ protocol to perform authorization. none Enter the keyword none to apply no authorization. Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
command Enter the command’s keywords to assign the command to a certain access level. You can enter one or all of the keywords. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. Obscure Password Commands To enable the obscure password, use the following commands. service obscure-passwords Enable the obscuring of passwords and keys.
If you are using role-based access control (RBAC), only the system administrator and security administrator roles can enable the service obscure-password command. Related Commands show running-config— Display the current configuration and display changes from the default values. service password-encryption— Encrypts all passwords configured in the system. Authentication and Password Commands To manage access to the system, use the following the commands.
Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.0 Introduced on the E-Series. By default, the Enable password is used. If you configure aaa authentication enable default, Dell Networking OS uses the methods defined for Enable access instead.
... method4 • line: use the password the password command defines in LINE mode. Not available if role-only is in use. • local: use the password for the userid contained in the local password database. • none: no authentication. Not available if role-only is in use. • radius: use the RADIUS servers configured with the radius-server host command. • tacacs+: use the TACACS+ servers configured with the tacacs-server host command. (OPTIONAL) Enter up to four additional methods.
After configuring the aaa authentication login command, configure the login authentication command to enable the authentication scheme on terminal lines. Connections to the SSH server work with the following login mechanisms: local, radius, and tacacs. Related Commands login authentication — enables AAA login authentication on the terminal lines. password — creates a password. radius-server host — specifies a RADIUS server host. tacacs-server host — specifies a TACACS+ server host.
enable password Change the password for the enable command. Syntax enable password [level level] [encryption-type] password To delete a password, use the no enable password [encryption-type] password [level level] command. Parameters level level (OPTIONAL) Enter the keyword level then a number as the level of access. The range is from 1 to 15. encryption-type (OPTIONAL) Enter the number 7 or 0 as the encryption type. Enter a 7 then a text string as the hidden password.
abcd]e, you type “abcd CNTL v ]e”. When the password is created, you do not use the CNTL + v key combination and enter “abcd]e”. NOTE: The question mark (?) and the tilde (~) are not supported characters. Related Commands show running-config — views the current configuration. privilege level (CONFIGURATION mode) — controls access to the command modes within the switch. enable restricted Allows Dell Networking technical support to access restricted commands.
enable secret Change the password for the enable command. Syntax enable secret [level level] [encryption-type] password To delete a password, use the no enable secret [encryption-type] password [level level] command. Parameters level level (OPTIONAL) Enter the keyword level then a number as the level of access. The range is from 1 to 15. encryption-type (OPTIONAL) Enter the number 5 or 0 as the encryption type. Enter a 5 then a text string as the hidden password.
abcd]e, you type “abcd CNTL v ]e”. When the password is created, you do not use the CNTL + v key combination and enter “abcd]e”. NOTE: The question mark (?) and the tilde (~) are not supported characters. Related Commands show running-config — views the current configuration. privilege level (CONFIGURATION mode) — controls access to the command modes within the switch. login authentication To configure authentication for console or remote access, apply an authentication method list.
Related Commands • If you configure the default authentication list using the default keyword, the list applies it to all the local and remote connections globally, unless you have specified some another authentication list for a specific connection. • If you configure an authentication lists other than default, you must apply those authentication lists to each connection.
Related Commands enable password — sets the password for the enable command. login authentication — configures an authentication method to log in to the switch. service password-encryption — encrypts all passwords configured in Dell Networking OS . radius-server key — configures a key for all RADIUS communications between the switch and the RADIUS host server. tacacs-server key — configures a key for communication between a TACACS+ server and client.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.5(0.0) Introduced lockout-period option on the Z9000, S6000, S4820T, S4810, and MXL. 9.2(1.0) Introduced on the Z9500. 9.0.2.
Version Description pre-6.1.1.0 Introduced on the E-Series. Usage Information CAUTION: Encrypting passwords with this command does not provide a high level of security. When the passwords are encrypted, you cannot return them to plain text unless you re-configure them. To remove an encrypted password, use the no password password command. To keep unauthorized people from viewing passwords in the switch configuration file, use the service password-encryption command.
show users Allows you to view information on all users logged in to the switch. Syntax show users [all] Parameters all (OPTIONAL) Enter the keyword all to view all terminal lines in the switch. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
6 idle 7 idle Dell# Related Commands vty 4 admin 10.16.127.141 vty 5 ad 10.16.127.141 unassigned 1 unassigned 15 username — enables a user. timeout login response Specify how long the software waits for the login input (for example, the user name and password) before timing out. Syntax timeout login response seconds To return to the default values, use the no timeout login response command. Parameters seconds Enter a number of seconds the software waits before logging you out.
username Establish an authentication system based on user names. Syntax username name [access-class access-list-name] [nopassword | {password | secret} [encryption-type] password] [privilege level] [role role-name] If you do not want a specific user to enter a password, use the nopassword option. To delete authentication for a user, use the no username name command. Parameters name Enter a text string for the name of the user up to 63 characters.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Added support for the secret option and the MD5 password encryption. Extended the name from 25 to 63 characters. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. Usage Information To view the defined user names, use the show running-config user command.
Version Description pre-6.2.1.0 Introduced on the E-Series. ip radius source-interface Specify an interface’s IP address as the source IP address for RADIUS connections. Syntax ip radius source-interface interface To delete a source interface, use the no ip radius source-interface command. Parameters interface Enter the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
radius-server deadtime Configure a time interval during which non-responsive RADIUS servers to authentication requests are skipped. Syntax radius-server deadtime seconds To disable this function or return to the default value, use the no radius-server deadtime command. Parameters seconds Enter a number of seconds during which non-responsive RADIUS servers are skipped. The range is from 0 to 2147483647 seconds. The default is 0 seconds.
Version Description 9.4.(0.0) Introduced on the S-Series and Z-Series. Example Dell(conf)#radius-server group group1 Dell(conf-radius-group)#radius-server host 1.1.1.1 key secret Dell(conf-radius-group)#radius-server host 2.2.2.2 key secret Dell(conf-radius-group)#radius-server vrf vrf1 source-interface tengigabitethernet 1/36 Dell(conf-radius-group)#show config ! radius-server group group1 radius-server vrf vrf1 source-interface TenGigabitEthernet 1/36 radius-server host 1.1.1.
• 7 means that the password is encrypted and hidden. Configure this parameter last because leading spaces are ignored. Defaults Command Modes Command History Not configured. • RADIUS SERVER GROUP • CONFIGURATION This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.
Example Dell(conf)#radius-server group group1 Dell(conf-radius-group)#radius-server host 1.1.1.1 key secret Dell(conf-radius-group)#no radius-server host 1.1.1.1 Related Commands login authentication — sets the database to be checked when a user logs in. radius-server key — sets an authentication key for RADIUS communications. radius-server retransmit — sets the number of times the RADIUS server attempts to send information.
Usage Information You can use this command to associate a group of RADIUS servers with a VRF and source interface. You can configure the source interface only with the VRF attribute and source interface is optional with the VRF attributes. If VRF is not configured on the RADIUS group, then the group is considered to be on the default VRF.
Usage Information Version Description 7.7.1.0 Authentication key length increased to 42 characters. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.0 Introduced on the E-Series. The key configured on the switch must match the key configured on the RADIUS server daemon. If you configure the key parameter in the radius-server host command, the key configured with the radius-server key command is the default key for all RADIUS communications.
radius-server timeout To reply to a request, configure the amount of time the RADIUS client (the switch) waits for a RADIUS host server . Syntax radius-server timeout seconds To return to the default value, use the no radius-server timeout command. Parameters seconds Enter the number of seconds between an unsuccessful attempt and the Dell Networking OS times out. The range is from zero (0) to 1000 seconds. The default is 5 seconds.
Parameters group-name Enter the name of the TACACS server group. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4.(0.0) Introduced on the S-Series and Z-Series.
Version Description 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.0 Introduced on the E-Series. ip tacacs source-interface Specify an interface’s IP address as the source IP address for TACACS+ connections. Syntax ip tacacs source-interface interface To delete a source interface, use the no ip tacacs source-interface command.
tacacs-server group Creates a group of TACACS servers. Syntax tacacs-server group group-name To delete a group of TACACS servers, use the no tacacs-server group group-name command. Parameters group-name Enter the name of the TACACS server group. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
timeout seconds (OPTIONAL) Enter the keyword timeout then the number of seconds the switch waits for a reply from the TACACS+ server. The range is from 0 to 1000. The default is 10 seconds. key key (OPTIONAL) Enter the keyword key then a string up to 42 characters long as the authentication key. This authentication key must match the key specified in the tacacs-server key for the TACACS+ daemon. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific.
Example Dell(conf)#tacacs-server group group1 Dell(conf-tacacs-group)#tacacs-server host 1.1.1.1 key secret Dell(conf-tacacs-group)#no tacacs-server host 1.1.1.1 Related Commands aaa authentication login — specifies the login authentication method. tacacs-server key — configures a TACACS+ key for the TACACS server. tacacs-server key Configure a key for communication between a TACACS+ server and a client.
tacacs-server vrf Create an association between a TACACS server group and a VRF and source interface. Syntax tacacs-server vrf vrf-name [source-interface interface] To delete the association between a TACACS server group and a VRF and source interface, use the no tacacs-server vrf vrf-name [source-interface interface] command. Parameters vrf vrf-name Enter the keyword vrf and then the name of the VRF to associate a TACACS server group with that VRF.
Dell(conf-tacacs-group)#tacacs-server vrf default Port Authentication (802.1X) Commands An authentication server must authenticate a client connected to an 802.1X switch port. Until the authentication, only Extensible Authentication Protocol over LAN (EAPOL) traffic is allowed through the port to which a client is connected. After authentication is successful, normal traffic passes through the port. Dell Networking OS supports RADIUS and Active Directory environments using 802.1X Port Authentication.
Related Commands Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series. dot1x authentication (Interface) — enables dot1x on an interface. dot1x authentication (Interface) Enable dot1x on an interface; dot1x must be enabled both globally and at the interface level. Syntax dot1x authentication To disable dot1x on an interface, use the no dot1x authentication command.
Defaults 3 attempts Command Modes CONFIGURATION (conf-if-interface-slot/port) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.7.
Version Description 7.6.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series. dot1x guest-vlan Configure a guest VLAN for limited access users or for devices that are not 802.1X capable. Syntax dot1x guest-vlan vlan-id To disable the guest VLAN, use the no dot1x guest-vlan vlan-id command. Parameters vlan-id Enter the VLAN Identifier. The range is from 1 to 4094. Defaults Not configured.
show dot1x interface — displays the 802.1X information on an interface. dot1x mac-auth-bypass Enable MAC authentication bypass. If 802.1X times out because the host did not respond to the Identity Request frame, Dell Networking OS attempts to authenticate the host based on its MAC address. Syntax [no] dot1x mac-auth-bypass Defaults Disabled Command Modes INTERFACE Command History This guide is platform-specific.
Related Commands Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series. interface range — configures a range of interfaces. dot1x port-control Enable port control on an interface.
Parameters seconds Enter the number of seconds. The range is from 1 to 65535. The default is 30. Defaults 30 seconds Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Related Commands Version Description 7.4.1.0 Introduced on the E-Series. interface range — configures a range of interfaces. dot1x reauth-max Configure the maximum number of times a port can re-authenticate before the port becomes unauthorized. Syntax dot1x reauth-max number To return to the default, use the no dot1x reauth-max command. Parameters number Enter the permitted number of re-authentications. The range is from 1 to 10. The default is 2.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the C-Series and S-Series. 7.4.
dot1x tx-period Configure the intervals at which EAPOL PDUs are transmitted by the Authenticator PAE. Syntax dot1x tx-period seconds To return to the default, use the no dot1x tx-period command. Parameters seconds Enter the interval time, in seconds, that EAPOL PDUs are transmitted. The range is from 1 to 65535 (1 year). The default is 30. Defaults 30 seconds Command Modes INTERFACE Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.
ReAuth Max: Supplicant Timeout: Server Timeout: Re-Auth Interval: Max-EAP-Req: Host Mode: Auth PAE State: Backend State: Dell# 2 30 seconds 30 seconds 3600 seconds 2 SINGLE_HOST Initialize Initialize SSH Server and SCP Commands Dell Networking OS supports secure shell (SSH) protocol versions 1.5 and 2.0. SSH is a protocol for secure remote login over an insecure network. SSH sessions are encrypted and use authentication. The SSH server and client are enhanced to support the VRF awareness functionality.
Usage Information Version Description 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. The host keys are required for key-exchange by the SSH server. If the keys are not found when you enable the server (ip This command requires user interaction and generates a prompt prior to overwriting any existing host keys. NOTE: Only a user with superuser permissions should generate host-keys. Example Dell(conf)#crypto key generate rsa Enter key size <1024-2048>.
Parameters client Enter the keyword client to enable collecting debug information on the client. server Enter the keyword server to enable collecting debug information on the server. Defaults Disabled on both client and server. Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. Usage Information To configure the switch as an SCP server, use the ip ssh server command. Related Commands ip ssh server — enables the SSH and SCP server on the switch. ip ssh authentication-retries Configure the maximum number of attempts that should be used to authenticate a user.
Parameters 1-10 Enter the number of maximum numbers of incoming SSH connections allowed per minute. The range is from 1 to 10 per minute. The default is 10 per minute. Defaults 10 per minute Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.
Usage Information Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. If you enable this command, clients can log in without a password prompt. This command provides two levels of authentication: • rhost-authentication is done with the file specified in the ip ssh rhostfile command. • checking client host-keys is done with the file specified in the ip ssh pub-key-file command.
ip ssh password-authentication Enable password authentication for the SSH server. Syntax ip ssh password-authentication enable To disable password-authentication, use the no ip ssh password-authentication enable command. Parameters enable Enter the keyword enable to enable password-authentication for the SSH server. Defaults Enabled Command Modes CONFIGURATION Command History This guide is platform-specific.
Defaults The default time is 60 minutes. The default volume is 1024 megabytes. Command Modes CONFIGURATION mode Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.5(0.
+DWEc3cgYAcU5Lai1MU2ODrzhCwyDNp05tKBU3t ReG1o8AxLi6+S4hyEMqHzkzBFNVqHzpQc +Rs4p2urzV0F4pRKnaXdHf3Lk4D460HZRhhVrxqeNxPDpEn WIMPJi0ds= ashwani@poclab4 NOTE: For rhostfile and pub-key-file, the administrator must FTP the file to the chassis. Example Dell#conf Dell(conf)# ip ssh pub-key-file flash://knownhosts Dell(conf)# Related Commands show ip ssh client-pub-keys — displays the client-public keys used for the host-based authentication.
ip ssh rsa-authentication (Config) Enable RSA authentication for the SSHv2 server. Syntax ip ssh rsa-authentication enable To disable RSA authentication, use the no ip ssh rsa-authentication enable command. Parameters enable Enter the keyword enable to enable RSA authentication for the SSHv2 server. Defaults Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific.
Parameters enable Enter the key word enable to start the SSH server. ciphers cipher-list Enter the keyword ciphers and then a space-delimited list of ciphers that the SSH server supports. The following ciphers are available. • 3des-cbc • aes128-cbc • aes192-cbc • aes256-cbc • aes128-ctr • aes192-ctr • aes256-ctr The default cipher list is used.
kex key-exchangealgorithm Enter the keyword kex and then a space-delimited list of key exchange algorithms supported by the SSH server. The following key exchange algorithms are available: • diffie-hellman-group-exchange-sha1 • diffie-hellman-group1-sha1 • diffie-hellman-group14-sha1 When FIPS is enabled, the default key-exchange-algorithm is diffie-hellmangroup14-sha1.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. This command enables the SSH server and begins listening on a port. If a port is not specified, listening is on SSH default port 22. NOTE: Starting with Dell Networking OS Release 9.2(0.0), SSH server is enabled by default.
Usage Information You can enable the SSH server on either a management VRF or a user defined VRF but not both. If no VRF is specified, then the SSH server is enabled on the default VRF. If the SSH server is enabled on a VRF with name vrf1, then use the following command to restart the SSH server on a VRF with name vrf2: ip ssh server vrf vrf2. If the SSH server is enabled on a VRF with name vrf1, then use the following command to restart the SSH server on the default VRF: ip ssh server vrf.
Usage Information The source-interface interface attribute is applicable for both the SSH client as well as the COPY (SCP) commands. Using these attributes the client session tags an error to the user during run time, in case there is a mismatch between this command and the ip ssh vrf command. Example Dell(conf)#ip ssh source-interface tengigabitethernet 1/42 Dell(conf)#do ssh 10.10.10.2 -l admin Dell(conf)#no ip ssh source-interface ip ssh vrf Specify a VRF for an outgoing SSH connections.
rsa Enter the keyword rsa to display the host SSHv2 RSA public key. rsa1 Enter the keyword rsa1 to display the host SSHv1 RSA public key. NOTE: If you enable FIPS mode, this parameter is not available. Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.
Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. Example Dell#show ip ssh SSH server : enabled. SSH server version : v1 and v2. SSH server vrf : default.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. Usage Information This command displays the contents of the flash://ADMIN_DIRssh/knownhosts file. Example Dell# show ip ssh client-pub-keys 4.8.1.
Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. Usage Information This command displays the contents of the flash:/ADMIN_DIR/ssh/authorized-keys.username file.
• aes128-cbc : Force ssh to use aes128-cbc encryption cipher • aes192-cbc : Force ssh to use aes192-cbc encryption cipher • aes256-cbc : Force ssh to use aes256-cbc encryption cipher • aes128-ctr : Force ssh to use aes128-ctr encryption cipher • aes192-ctr : Force ssh to use aes192-ctr encryption cipher • aes256-ctr : Force ssh to use aes256-ctr encryption cipher -l username (OPTIONAL) Enter the keyword -l then the user name used in this SSH session.
Usage Information Dell Networking OS supports both inbound and outbound SSH sessions using IPv4 or IPv6 addressing. Inbound SSH supports accessing the system through the management interface as well as through a physical Layer 3 interface. Example Dell#ssh 10.16.151.48 -l anvltest Trying 10.16.151.48... 01:18:16: %STKUNIT0-M:CP %SEC-5-SSH_USAGE: Initiated SSH Client v2 (FIPS Disabled) to anvltest@10.16.151.48 by default from console anvltest@10.16.151.
Parameters trust-downstream Configure the system to trust Option 82 when it is received from the previous-hop router. vrf Enter the keyword vrf to include VRF related information in the Option 82. This configuration enables the relay agent to include VRF related information when it forwards the broadcasts from client to DHCP server. Defaults Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific.
Usage Information When enabled, no learning takes place until you enable snooping on a VLAN. After disabling DHCP Snooping, the binding table is deleted and Option 82, IP Source Guard, and Dynamic ARP Inspection are disabled. Related Commands ip dhcp snooping vlan — enables DHCP Snooping on one or more VLANs. ip dhcp snooping binding Create a static entry in the DHCP binding table.
Related Commands Version Description 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the C-Series and S-Series. show ip dhcp snooping — displays the contents of the DHCP binding table. ip dhcp snooping database renew Renew the binding table. Syntax ip dhcp snooping database renew Defaults none Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the C-Series and S-Series. ip dhcp source-address-validation Enable IP source guard. Syntax [no] ip dhcp source-address-validation Defaults Disabled. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the C-Series and S-Series. When enabled, the system begins creating entries in the binding table for the specified VLANs. NOTE: Learning only happens if there is a trusted port in the VLAN. Related Commands ip dhcp snooping trust — configures an interface as trusted. show ip dhcp snooping Display the contents of the DHCP binding table.
• aaa authorization commands • authorization • show accounting • show users • username aaa authorization role-only Configure authentication to use the user’s role only when determining if access to commands is permitted. Syntax aaa authorization role-only To return to the default setting, use the no aaa authentication role-only command. Parameters name Enter a text string for the name of the user up to 63 characters.
Parameters mode Enter one of the following keywords as the mode for which you are controlling access: configure for CONFIGURATION mode exec for EXEC mode interface for INTERFACE modes line for LINE mode route-map for Route-map mode router for Router mode addrole Enter the keyword addrole to add permission to the command. You cannot add or delete rights for the sysadmin role. deleterole Enter the keyword deleterole to remove access to the command. You cannot add or delete rights for the sysadmin role.
Defaults none Command Modes EXEC Privilege Command History Examples • route-map • router Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.
To delete a role name, use the no userrole name command. Note that the reserved role names may not be deleted. Parameters name Enter a text string for the name of the user up to 63 characters. It cannot be one of the system defined roles (sysadmin, secadmin, netadmin, netoperator). inherit existing-rolename Enter the inherit keyword then specify the system defined role to inherit permissions from (sysadmin, secadmin, netadmin, netoperator).
47 Service Provider Bridging Service provider bridging is composed of virtual local area network (VLAN) Stacking, Layer 2 Protocol Tunneling, and Provider Backbone Bridging as described in the Dell Networking OS Configuration Guide Service Provider Bridging chapter. This chapter includes command line information (CLI) for the Dell Networking operating software Layer 2 Protocol Tunneling (L2PT). L2PT enables protocols to tunnel through an 802.1q tunnel. Dell Networking OS supports L2PT on Dell Networking OS.
• For a Port Channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. in | out | both Enter the keyword in, out, or both to debug incoming interfaces, outgoing interfaces, or both incoming and outgoing interfaces. vlan vlan-id Enter the keyword vlan then the VLAN ID. The range is from 1 to 4094. count value Enter the keyword count then the number of debug outputs. The range is from 1 to 100. Defaults Debug disabled.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guid. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.11.1 Introduced on the Z9000. 8.5.1.1 Added support for 802.1X, E-LMI, GMRP, GVRP, LLDP, LACP, MMRP, MVRP, and OAM 802.
Version Description 7.4.1.0 Introduced Usage Information When you enable VLAN-Stacking, no protocol packets are tunneled. Related Command show protocol-tunnel — displays tunneling information for all VLANs. protocol-tunnel enable Enable protocol tunneling globally on the system. Syntax protocol-tunnel enable To disable protocol tunneling, use the no protocol-tunnel enable command. Defaults Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series, E-Series and E-Series ExaScale. 7.4.1.
48 sFlow The Dell Networking operating software (OS) supports sFlow commands on Dell Networking OS. Dell Networking operating software sFlow monitoring system includes an sFlow Agent and an sFlow Collector. • The sFlow Agent combines the flow samples and interface counters into sFlow datagrams and forwards them to the sFlow Collector. • The sFlow Collector analyses the sFlow Datagrams received from the different devices and produces a network-wide view of traffic flows.
To delete a configured collector, use the no sflow collector {ip-address | ipv6-address} agent-addr {ipv4-address | ipv6-address} [number [max-datagram-size number]] | [max-datagram-size number] [vrf management] command. Parameters sflow collector ipaddress | ipv6address Enter the IP address of the collector in dotted decimal format for IPv4 or x:x:x:x::x format for IPv6.
Usage Information Version Description 6.2.1.1 Introduced on the E-Series. You can configure up to two sFlow collectors (IPv4 or IPv6). If two collectors are configured, traffic samples are sent to both. The sFlow agent address is carried in a field in SFlow packets and is used by the collector to identify the sFlow agent. In sFlow, the agent address is a single invariant IPv4 or IPv6 address used to identify the agent to the collector.
Version Description 7.6.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. Usage Information sFlow is disabled by default. In addition to this command, sFlow needs to be enable on individual interfaces where sFlow sampling is desired. Related Commands sflow enable (Interface) — enables sFlow on interfaces. sflow ingress-enable Enable sFlow ingress on interfaces. Syntax sflow ingress-enable To disable sFlow, use the no sflow ingress enable command. Defaults Disabled.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on S-Series Stacking. 8.1.1.
Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.7(0.0) Introduced on the S Series and Z Series switches. Dell(conf)#sflow max-header-size extended sflow polling-interval (Global) Set the sFlow polling interval at a global level. Syntax sflow polling-interval interval value To return to the default, use the no sflow polling-interval interval command. Parameters interval value Enter the interval value in seconds. The range is from 15 to 86400 seconds. The default is 20 seconds.
sflow polling-interval (Interface) Set the sFlow polling interval at an interface (overrides the global-level setting.) Syntax sflow polling-interval interval value To return to the default, use the no sflow polling-interval interval command. Parameters interval value Enter the interval value in seconds. The range is from 15 to 86400 seconds. The default is the global counter polling interval. Defaults The same value as the current global default counter polling interval.
Defaults 32768 packets Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on S-Series Stacking. 8.1.1.0 Introduced on the E-Series ExaScale. 7.7.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on S-Series Stacking. 8.1.1.
49 Simple Network Management Protocol (SNMP) and Syslog This chapter contains commands to configure and monitor the simple network management protocol (SNMP) v1/v2/v3 and Syslog. Both features are supported on Dell Networking OS. The chapter contains the following sections: • SNMP Commands • Syslog Commands SNMP Commands The following SNMP commands are available in the Dell Networking OS.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. Example Dell#show snmp engineID Local SNMP engineID: 0000178B02000001E80214A8 Remote Engine ID IP-addr Port 80001F88043132333435 172.31.1.3 5009 80001F88043938373635 172.31.1.
Example Dell#show snmp group groupname: v1v2creadg readview : v1v2cdefault notifyview: v1v2cdefault row status: active Dell# Related Commands security model: v1 writeview: no write view specified context: no context specified snmp-server group — configures an SNMP server group. show snmp user Display the information configured on each SNMP user name. Syntax show snmp user Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.
ipv6 access-listname (Optional) Enter the keyword ipv6 then an IPv6 ACL name (a string up to 16 characters long). security-name name (Optional) Enter the keywords security-name then the security name as defined by the community MIB. access-list-name (Optional) Enter a standard IPv4 access list name (a string up to 16 characters long). Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific.
Example Dell#config Dell(conf)# snmp-server community public ro Dell(conf)# snmp-server community guest ro security-name guestuser Dell(conf)# Example Dell(conf)# ip access-list standard snmp-ro-acl Dell(config-std-nacl)#seq 5 permit host 10.10.10.224 Dell(config-std-nacl)#seq 10 deny any count ! Dell(conf)#snmp-server community guest ro snmp-ro-acl Dell(conf)# Related Commands ip access-list standard — names (or selects) a standard access list to filter based on IP address.
snmp-server enable traps Enable SNMP traps. Syntax snmp-server enable traps [notification-type] [notification-option] To disable traps, use the no snmp-server enable traps [notification-type] [notification-option] command. Parameters notification-type notification-option Enter the type of notification from the following list: • bgp — Notification of changes in the BGP process. • config — Notification of changes to the startup or running configuration. • ecfm — Notification of changes to ECFM.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Added the following two SNMP notification options: syslog-reachable and syslog-unreachable. 9.7(0.0) Introduced on the S6000-ON. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 9.0.2.0 Introduced on the S6000. 9.1(0.0) Added support for copy-config and ECMP traps. 8.3.19.0 Introduced on the S4820T. 8.3.11.
vrf vrf-name Enter the keyword vrf followed by the name of the VRF that is used to reach the device. NOTE: Use this attribute to specify the VRF that is used by the SNMP engine to reach the device. If no VRF is specified, then the default VRF is used. udp-port portnumber engineID Enter the keywords udp-port followed by the user datagram protocol (UDP) port number on the remote device. The range is from 0 to 65535. The default is 162. Defaults As above.
snmp-server group Configure a new SNMP group or a table that maps SNMP users to SNMP views.
Defaults As above. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.10.
NOTE: The :: notation specifies successive hexadecimal fields of zero. vrf vrf-name Enter the keyword vrf and then the name of the VRF that the SNMP server uses to connect to the host. NOTE: You can use this attribute to inform the SNMP engine about the vrf instance to be used to reach the corresponding remote host to send Trap or Inform message. If no VRF is specified, then the default VRF is used. traps (OPTIONAL) Enter the keyword traps to send trap notifications to the specified host.
• lacp — Enable LACP state change traps. • isis — Enable ISIS adjacency change traps • pfc — Enable pfc traps • snmp — Enable SNMP trap • stp — Enable 802.1d state change traps • vlt — Enable VLT traps • vrrp — Enable VRRP state change traps • xstp — Enable 802.1s, 802.1w, and PVST+ state change traps The default is all trap types are sent to host. Defaults As above. Command Modes CONFIGURATION Command History This guide is platform-specific.
The snmp-server host command is used with the snmp-server enable command. Use the snmpserver enable command to specify which SNMP notifications are sent globally. For a host to receive most notifications, at least one snmp-server enable command and the snmp-server host command for that host must be enabled.
Version Description E-Series legacy command snmp-server packetsize Set the largest SNMP packet size permitted. Wen the SNMP server is receiving a request or generating a reply, use the snmpserver packetsize global configuration command. Syntax snmp-server packetsize byte-count Parameters byte-count Enter one of the following values 8, 16, 24 or 32. Packet sizes are 8000 bytes, 16000 bytes, 32000 bytes, and 64000 bytes.
• For a port channel interface, enter the keywords port-channel then a number. • For a Null interface, enter the keyword null then the Null interface number. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. Defaults The IP address assigned to the management interface is the default. Command Modes CONFIGURATION Command History This guide is platform-specific.
group_name Enter a text string (up to 20 characters long) as the name of the group. The following groups are created for mapping to read/write community/security-names (defaults): • v1v2creadu — maps to a community with ro permissions. • 1v2cwriteu — maps to a community rw permissions. remote ip-address Enter the keywords udp-port then the user datagram protocol (UDP) port number on the remote device. The range is from 0 to 65535. The default is 162.
ipv6 access-listname (Optional) Enter the keyword ipv6 then the IPv6 access list name (a string up to 16 characters long). access-list-name ipv6 access-listname (Optional) Enter both an IPv4 and IPv6 access list name. Defaults As above. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Example Dell#conf Dell(conf)# snmp-server user n3user ngroup remote 172.31.1.3 udp-port 5009 3 auth md5 authpasswd Related Commands show snmp user — displays the information configured on each SNMP user name. snmp-server user (for AES128-CFB Encryption) Specify that AES128-CFB encryption algorithm needs to be used for transmission of SNMP information. The Advanced Encryption Standard (AES) Cipher Feedback (CFB) 128-bit encryption algorithm is in compliance with RFC 3826.
command in Global Configuration mode. You can enable or disable FIPS mode only if SNMPv3 users are not previously set up. Otherwise, you must remove the previously configured users before you change the FIPS mode. Example Dell# snmp-server user privuser v3group v3 encrypted auth md5 9fc53d9d908118b2804fe80e3ba8763d priv aes128 d0452401a8c3ce42804fe80e3ba8763d Related Commands show snmp user — Displays the information configured on each SNMP user name. snmp-server view Configure an SNMPv3 view.
snmp-server vrf Configures an SNMP agent to bind to a specific VRF. Syntax snmp-server vrf vrf-name To undo the SNMP agent configuration, use the no snmp-server vrf vrf-name command. Parameters vrf vrf-name Enter the keyword vrf and then the name of the VRF to associate an SNMP agent with that VRF. Defaults Not Enabled. Command Modes CONFIGURATION Command History This guide is platform-specific.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series legacy command Usage Information If the interface is expected to flap during normal usage, you could disable this command. Syslog Commands The following commands allow you to configure logging functions on all Dell Networking switches. clear logging Clear the messages in the logging buffer.
clear logging auditlog Clears audit log. Syntax clear logging auditlog Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the S4810, S4820T, S6000, Z9000, and MXL.
default logging console Return the default settings for messages logged to the console. Syntax default logging console Defaults level = 7 or debugging Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Version Description 7.5.1.0 Introduced on the C-Series. E-Series legacy command Related Commands logging monitor — sets the logging monitor parameters. terminal monitor — sends system messages to the terminal/monitor. default logging trap Return to the default settings for logging messages to the Syslog servers. Syntax default logging trap Defaults level = 6 or informational Command Modes CONFIGURATION Command History This guide is platform-specific.
NOTE: The :: notation specifies successive hexadecimal fields of zeros. hostname Enter the name of a host already configured and recognized by the switch. udp Enter the keyword udp to enable transmission of log message over UDP followed by port number. The default port is 514 tcp Enter the keyword tcp to enable transmission of log message over TCP followed by port number. vrf vrf-name (Optional) Enter the keyword vrf and then the name of the VRF to enable the logging process in VRF mode.
logging buffered Enable logging and specify which messages are logged to an internal buffer. By default, all messages are logged to the internal buffer. Syntax logging buffered [level] [size] To return to the default values, use the default logging buffered command. To disable logging stored to an internal buffer, use the no logging buffered command.
logging console Specify which messages are logged to the console. Syntax logging console [level] To return to the default values, use the default logging console command. To disable logging to the console, use the no logging console command. Parameters level (OPTIONAL) Indicate a value from 0 to 7 or enter one of the following parameters: emergencies, alerts, critical, errors, warnings, notifications, informational, or debugging. The default is 7 or debugging.
Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the S4810, S4820T, S6000, Z9000, and MXL. This command is available with or without RBAC enabled.
• lpr (line printer system) • mail (mail system) • news (USENET news) • sys9 (system use) • sys10 (system use) • sys11 (system use) • sys12 (system use) • sys13 (system use) • sys14 (system use) • syslog (Syslog process) • user (user process) • uucp (Unix to Unix copy process) The default is local7. Defaults local7 Command Modes CONFIGURATION Command History This guide is platform-specific.
Parameters level Indicate a value from 0 to 7 or enter one of the following equivalent words: emergencies, alerts, critical, errors, warnings, notifications, informational, or debugging. The default is 4 or warnings. Defaults warnings or 4 Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series legacy command Usage Information When the number of messages reach the limit you set with the logging history size command, older messages are deleted as newer ones are added to the table.
Version Description 7.5.1.0 Introduced on the C-Series. E-Series legacy command Related Commands default logging monitor — returns the logging monitor parameters to the default setting. logging on Specify that debug or error messages are asynchronously logged to multiple destinations, such as the logging buffer, Syslog server, or terminal lines. Syntax logging on To disable logging to logging buffer, Syslog server and terminal lines, use the no logging on command. Defaults Enabled.
logging source-interface Specify that the IP address of an interface is the source IP address of Syslog packets sent to the Syslog server. Syntax logging source-interface interface To disable this command and return to the default setting, use the no logging source-interface command. Parameters interface Enter the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
Usage Information Syslog messages contain the IP address of the interface used to egress the router. By configuring the logging source-interface command, the Syslog packets contain the IP address of the interface configured. Related Commands logging — enables logging to the Syslog server. logging synchronous Synchronize unsolicited messages and Dell Networking OS output.
If the message queue limit is reached on a terminal line and messages are discarded, a system message appears on that terminal line. Messages may continue to appear on other terminal lines. Related Commands logging on — enables logging. logging trap Specify which messages are logged to the Syslog server based the message severity. Syntax logging trap [level] To return to the default values, use the default logging trap command. To disable logging, use the no logging trap command.
logging version Displays syslog messages in a RFC 3164 or RFC 5424 format. Syntax logging version {0|1} Defaults 0 Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.
Example Dell(conf)#show logging audit Related Commands clear logging auditlog — clears audit log. show logging Display the logging settings and system messages logged to the internal buffer of the switch. Syntax Parameters Command Modes Command History show logging [number | history [reverse][number] | reverse [number] | summary] number (OPTIONAL) Enter the number of messages displayed in the output. The range is from 1 to 65535.
Oct 8 09:25:37: %RPM1:RP1 %BGP-5-ADJCHANGE: 223.80.255.254 closed.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. This command displays internal software driver information, which may be useful during troubleshooting switch initialization errors, such as a downed Port-Pipe. terminal monitor Configure the Dell Networking OS to display messages on the monitor/terminal.
50 SNMP Traps This chapter lists the traps sent by the Dell Networking operating software. Each trap is listed by the fields Message ID, Trap Type, and Trap Option. Message ID Trap Type Trap Option COLD_START SNMP COLDSTART WARM_START SNMP WARMSTART COPY_CONFIG_COMPLETE SNMP NONE SNMP LINKDOWN SNMP LINKUP SNMP AUTH EGP_NEIGHBOR_LOSS SNMP NONE OSTATE_DOWN SNMP LINKDOWN SNMP LINKUP SNMP NONE SNMP NONE SNMP NONE SNMP NONE %SNMP-5-SNMP_COLD_START: SNMP COLD_START trap sent.
Message ID Trap Type Trap Option SNMP NONE SNMP NONE SNMP NONE NONE NONE ENVMON NONE ENVMON NONE ENVMON NONE CHM_CARD_PROBLEM ENVMON NONE CHM_ALARM_CUTOFF ENVMON NONE CHM_SFM_UP ENVMON NONE CHM_SFM_DOWN ENVMON NONE CHM_RPM_UP ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE %RPM0-P:CP %SNMP-4-RMON_HC_FALLING_THRESHOLD: RMON highcapacity falling threshold alarm from SNMP OID BER_ERR %IFMGR-5-BER_ERR: High Ber detected on interface : %s BER_ERR_CLR %IFMGR-5-BER_ERR_C
Message ID Trap Type Trap Option CHM_SFM_REMOVE ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE ENVMON SUPPLY ENVMON SUPPLY ENVMON SUPPLY ENVMON SUPPLY ENVMON SUPPLY ENVMON SUPPLY ENVMON TEMP ENVMON TEMP ENVMON TEMP ENVMON TEMP ENVMON FAN %TSM-5-SFM_REMOVE: Removed SFM 1 CHM_MAJ_SFM_DOWN %CHMGR-0-MAJOR_SFM: Major alarm: Switch fabric down CHM_MAJ_SFM_DOWN_CLR %CHMGR-5-MAJOR_SFM_CLR: Major alarm cleared: Switch fabric up CHM_MIN_SFM_DOWN %CHMGR-2-MINOR_SFM: MIn
Message ID Trap Type Trap Option ENVMON FAN ENVMON FAN ENVMON FAN ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE For E1200: %CHMGR-2-FAN_TRAY_BAD: Major alarm: fan tray %d is missing or down %CHMGR-2-ALL_FAN_BAD: Major alarm: all fans in fan tray %d are down.
Message ID Trap Type Trap Option ENVMON NONE ENVMON NONE ENVMON NONE PROTO NONE PROTO NONE PROTO NONE PROTO NONE PROTO NONE %MACMGR-5-DETECT_STN_MOVE: Station Move threshold exceeded for Mac %s in vlan %d PORT_TEMP_MAJOR %CHMGR-1-PORT_TEMP_MAJOR: Major Alarm Interface %s shut due to high temperature PORT_TEMP_MINOR %CHMGR-1-PORT_TEMP_MINOR: Minor Alarm Interface %s temperature exceeds threshold PORT_TEMP_MAJOR_CLR %CHMGR-1-PORT_TEMP_MAJOR_CLR: Major Alarm cleared for Interface %s port tem
51 Stacking All commands in this chapter are specific to the Dell Networking operating software. You can use the commands to pre-configure a switch, so that the configuration settings are invoked when the switch is attached to other S-Series units. For information about using the S-Series stacking feature, refer to the “Stacking S-Series Switches” chapter in the Dell Networking OS Configuration Guide. CAUTION: You cannot enable stacking simultaneously with virtual link trunking (VLT).
Usage Information Enabling this command keeps the failed switch in the Failed state. The switch does not reboot until it is manually rebooted. When enabled, it is not displayed in the running-config. When disabled, it is displayed in the running-config. Related Commands show redundancy — displays the current redundancy status. redundancy force-failover stack-unit Force the standby unit in the stack to become the management unit.
Version Description 9.7(0.0) Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.3.1.0 Added the members option. reset stack-unit Reset any designated stack member except the management unit (master unit). Syntax Parameters reset stack-unit <0–5> hard stack-unit Enter the stack-unit number. The range is from 0 to 5. hard Reset the stack unit if the unit is in a problem state.
5 6 7 8 9 10 11 Related Commands • Member Member Member Member Member Member Member not not not not not not online S6000 present present present present present present S6000 9.7.0.0 128 reload – reboots Dell Networking OS. show redundancy Display the current redundancy configuration (status of automatic reboot configuration on stack management unit). Syntax show redundancy Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific.
Primary Stack-unit: mgmt-id 0 Auto Data Sync: Full Failover Type: Hot Failover Auto reboot Stack-unit: Disabled Auto failover limit: 3 times in 60 minutes -- Stack-unit Failover Record ------------------------------------------------Failover Count: 0 Last failover timestamp: None Last failover Reason: None Last failover type: None -- Last Data Block Sync Record: ------------------------------------------------stack-unit Config: no block sync done Start-up Config: no block sync done Runtime Event Log: no blo
Field Description Topology Lists the topology of stack ports connected: Ring, Daisy chain, or Standalone. Interface The unit/port ID of the connected stack port on this unit. Link Speed Link Speed of the stack port (10 or 40) in Gb/s. Admin Status The only currently listed status is Up. Connection The stack port ID to which this unit’s stack port is connected.
Parameters stack-number Enter the stack member unit identifier. 1–14 This preference parameter allows you to specify the management priority of one backup switch over another, with 0 the lowest priority and 14 the highest. The switch with the highest priority value is chosen to become the management unit if the active management unit fails or on the next reload. Defaults 0 Command Modes CONFIGURATION Command History This guide is platform-specific.
Related Commands Version Description 8.3.7.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. • reload – reboots Dell Networking OS. • show system (S-Series and Z-Series) – displays the status of all stack members or a specific member. stack-unit stack-group Configure the stacking unit and stacking group by specifying an ID when adding units to a stack to ensure the unit is assigned to the correct group.
upgrade system stack-unit Copy the boot image or Dell Networking OS from the management unit to one or more stack members. Syntax Parameters upgrade {boot | system} stack-unit {all | stack-unit-number | A | B} boot Enter the keyword boot to copy the boot image from the management unit to the designated stack members. system Enter the keyword system to copy the Dell Networking OS image from the management unit to the designated stack members. stack-unit Enter the stack-unit number.
52 Storm Control The Dell Networking operating software storm control feature allows you to limit or suppress traffic during a traffic storm (Broadcast/Unknown Unicast Rate Limiting or Multicast on the C-Series and S-Series). Storm control is supported on Dell Networking OS. Important Points to Remember • Interface commands can only be applied on physical interfaces (virtual local area networks [VLANs] and link aggregation group [LAG] interfaces are not supported).
• Defaults Command Modes Command History For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. none • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 E-Series Only: Added the percentage decimal value option. 6.5.1.0 Introduced on the E-Series.
Version Description 7.4.1.0 E-Series Only: Added the percentage decimal value option. 6.5.1.0 Introduced on the E-Series. storm-control multicast (Configuration) Configure the packets per second (pps) of multicast traffic allowed into the C-Series and S-Series networks only. Syntax storm-control multicast packets_per_second in To disable storm-control for multicast traffic into the network, use the no storm-control multicast packets_per_second in command.
To disable multicast storm control on the interface, use the no storm-control multicast packets_per_second in command. Parameters packets_per_secon d in Enter the packets per second of broadcast traffic allowed into the network. The range is from 0 to 33554368. Defaults none Command Modes INTERFACE (conf-if-interface-slot/port) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 E-Series Only: Added the percentage decimal value option. 6.5.1.0 Introduced on the E-Series. Unknown Unicast Storm-Control is valid for Layer 2 and Layer 2/Layer 3 interfaces.
Storm Control Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 E-Series Only: Added the percentage decimal value option. 6.5.1.0 Introduced on the E-Series.
53 Spanning Tree Protocol (STP) The commands in this chapter configure and monitor the IEEE 802.1d spanning tree protocol (STP) and are supported on the Dell Networking switch/routing platform. bridge-priority Set the bridge priority of the switch in an IEEE 802.1D spanning tree. Syntax bridge-priority {priority-value | primary | secondary} To return to the default value, use the no bridge-priority command. Parameters priority-value Enter a number as the bridge priority value.
bpdu-destination-mac-address Use the Provider Bridge Group address in Spanning Tree or GVRP PDUs. Syntax bpdu-destination-mac-address [stp | gvrp] provider-bridge-group Parameters xstp Force STP, RSTP, and MSTP to use the Provider Bridge Group address as the destination MAC address in its BPDUs. gvrp Forces GVRP to use the Provider Bridge GVRP Address as the destination MAC address in its PDUs. Defaults The destination MAC address for BPDUs is the Bridge Group Address.
Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.
Related Commands Version Description 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced protocol spanning-tree — enters SPANNING TREE mode on the switch. disable Disable the spanning tree protocol globally on the switch. Syntax disable To enable Spanning Tree Protocol, use the no disable command. Defaults Enabled (that is, the spanning tree protocol is disabled.) Command Modes SPANNING TREE Command History This guide is platform-specific.
Defaults 15 seconds Command Modes SPANNING TREE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Related Commands Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. forward-delay — changes the wait time before STP transitions to the Forwarding state. max-age — changes the wait time before STP refreshes protocol configuration information.
protocol spanning-tree To enable and configure the spanning tree group, enter SPANNING TREE mode. Syntax protocol spanning-tree stp-id To disable the Spanning Tree group, use the no protocol spanning-tree stp-id command. Parameters stp-id Enter zero (0). Dell Networking OS supports one spanning tree group, group 0. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific.
Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.
Example Field Description “Designated port...” Displays the designated port ID. Dell#show spann 0 Executing IEEE compatible Spanning Tree Protocol Bridge Identifier has priority 32768, Address 0001.e800.0a56 Configured hello time 2, max age 20, forward delay 15 We are the root of the spanning tree Current root has priority 32768 address 0001.e800.
Usage Information Example (Guard) The following describes the show spanning-tree 0 guard command shown in the example. Field Description Interface Name STP interface. Instance STP 0 instance. Sts Port state: root-inconsistent (INCON Root), forwarding (FWD), listening (LIS), blocking (BLK), or shut down (EDS Shut). Guard Type Type of STP guard configured (Root, Loop, or BPDU guard).
Enter the optional keyword shutdown-on-violation to hardware disable an interface when a BPDU is received and the port is disabled. priority priority Enter keyword priority then a number as the priority. The range is from zero (0) to 15. The default is 8. Defaults cost = depends on the interface type; priority = 8 Command Modes INTERFACE Command History This guide is platform-specific.
• If a BPDU is received from a remote device, BPDU guard places the port in an Err-Disabled Blocking state and no traffic is forwarded on the port. • If no BPDU is received from a remote device, loop guard places the port in a Loop-Inconsistent Blocking state and no traffic is forwarded on the port. To display the type of STP guard (Portfast BPDU, root, or loop guard) enabled on a port, enter the show spanning-tree 0 command.
54 System Time and Date The commands in this chapter configure time values on the system, either using the Dell Networking operating software, or the hardware, or using the network time protocol (NTP). With NTP, the switch can act only as a client to an NTP clock host. For more information, refer to the “Network Time Protocol” section of the Management chapter in the Dell Networking OS Configuration Guide.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
start-month Enter the name of one of the 12 months in English. start-time Enter the time in hours:minutes. For the hour variable, use the 24-hour format; example, 17:15 is 5:15 pm. end-week Enter the one of the following as the week that daylight saving ends: • week-number: enter a number from 1 to 4 as the number of the week to end daylight saving time. • first: enter the keyword first to end daylight saving time in the first week of the month.
clock timezone Configure a timezone for the switch. Syntax clock timezone timezone-name offset To delete a timezone configuration, use the no clock timezone command. Parameters timezone-name Enter the name of the timezone. You cannot use spaces. offset Enter one of the following: • a number from 1 to 23 as the number of hours in addition to universal time coordinated (UTC) for the timezone. • a minus sign (-) then a number from 1 to 23 as the number of hours. Defaults Not configured.
Parameters adjust Enter the keyword adjust to display information on NTP clock adjustments. all Enter the keyword all to display information on all NTP transactions. authentication Enter the keyword authentication to display information on NTP authentication transactions. events Enter the keyword events to display information on NTP events. loopfilter Enter the keyword loopfilter to display information on NTP local clock frequency.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series. You also must configure an authentication key for NTP traffic using the ntp authentication-key command.
ntp disable Prevent an interface from receiving NTP packets. Syntax ntp disable To re-enable NTP on an interface, use the no ntp disable command. Defaults Disabled (that is, if you configure an NTP host, all interfaces receive NTP packets) Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.4.1.0 Added support for IPv6 multicast addresses. 8.3.7.0 Introduced on the S4810.
Parameters vrf vrf-name (Optional) Enter the keyword vrf and then the name of the VRF to configure a NTP time-serving host corresponding to that VRF. ipv4-address | ipv6address Enter an IPv4 address (A.B.C.D) or IPv6 address (X:X:X:X::X) of NTP server. hostname Enter the hostname of the server. key keyid (OPTIONAL) Enter the keyword key and a number as the NTP peer key. The range is from 1 to 4294967295.
ntp source Specify an interface’s IP address to be included in the NTP packets. Syntax ntp source interface To delete the configuration, use the no ntp source command. Parameters interface Enter the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.11.1 Introduced on the Z9000. 7.6.1.0 Introduced on the S-Series. 7.5.1.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.11.1 Introduced on the Z9000. 8.2.1.0 Added options [0 | 7] for entering the authentication key. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series. Example Dell#show clock 11:05:56.949 UTC Thu Oct 25 2001 Dell# Example (Detail) Dell#show clock detail 12:18:10.
Usage Information Version Description 6.1.1.0 Introduced on the E-Series. The following describes the show ntp associations command shown in the Example below. Field Description (none) One or more of the following symbols could be displayed: • * means synchronized to this peer. • # means almost synchronized to this peer. • + means the peer was selected for possible synchronization. • - means the peer is a candidate for selection. • ~ means the peer is statically configured.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.6(0.0) Added support for VRF. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.11.1 Introduced on the Z9000. 8.4.1.0 Added IPv6 support. 7.6.1.
Field Description “Clock is...” States whether or not the switch clock is synchronized, which NTP stratum the system is assigned and the IP address of the NTP peer. “frequency is...” Displays the frequency (in ppm), stability (in ppm) and precision (in Hertz) of the clock in this system. “reference time is...” Displays the reference time stamp. “clock offset is...” Displays the system offset to the synchronized peer and the time delay on the path to the NTP root clock. “root dispersion is...
55 Tunneling Tunneling is supported on Dell Networking OS. ip unnumbered Configure a tunnel interface to operate without a unique IPv4 address and select the interface from which the tunnel borrows its address. Syntax ip unnumbered {interface-type slot/port} To set the tunnel back to default logical address use the no ip unnumbered command. If the tunnel was previously operational, the tunnel interface is operationally down unless you also configure the tunnel IPv6 address.
ipv6 unnumbered Configure a tunnel interface to operate without a unique IPv6 address and select the interface from which the tunnel borrows its address. Syntax ipv6 unnumbered {interface-type interface-number} To set the tunnel back to default logical address use the no ipv6 unnumbered command. If the tunnel was previously operational, the tunnel interface is operationally down unless you also configure the tunnel IPv4 address.
tunnel allow-remote Configure an IPv4 or IPv6 address or prefix whose tunneled packets are accepted for decapsulation. If you do not configure allowremote entries, tunneled packets from any remote peer address is accepted. This feature is supported on Dell Networking OS. Syntax tunnel allow-remote {ip-address | ipv6-address} [mask] To delete a configured allow-remote entry use the no tunnel allow-remote command. Any specified address/mask values must match an existing entry for the delete to succeed.
To delete a tunnel destination address, use the no tunnel destination {ip-address | ipv6– address} command. Parameters ip-address Enter the destination IPv4 address for the tunnel. ipv6–address Enter the destination IPv6 address for the tunnel. Defaults none Command Modes INTERFACE TUNNEL (conf-if-tu) Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.3(0.0) Introduced on the S4810, S4820T, S6000 and Z9000.
Usage Information Version Description 9.5(0.1) Introduced on the Z9500. 9.3(0.0) Introduced on the S6000, S4810, S4820T, Z9000. This command configures the method used to set the high 6 bits (the differentiated services codepoint) of the IPv4 TOS or the IPv6 traffic class in the outer IP header. A value of 0 copies original packet DSCP (IPv4)/Traffic Class (IPv6) to the tunnel header DSCP (IPv4)/ Traffic Class (IPv6) depending on the mode of tunnel.
Command Modes Command History Usage Information INTERFACE TUNNEL (conf-if-tu) Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.3(0.0) Introduced on the S6000, S4810, S4820T, Z9000. A value of 0 copies the inner packet hop limit (ipv6) or time-to-live (ipv4) in the encapsulated packet to the tunnel header hop limit (ipv6) or time-to-live (ipv4) value. tunnel keepalive Configure the tunnel keepalive target, interval and attempts.
Usage Information Enabling tunnel keepalive causes ICMP echo packets to be sent to the keepalive target. The ICMP echo will be sourced from the tunnel interface logical IPv4 or IPv6 address and will be tunnel encapsulated. The response will be accepted whether it returns tunnel encapsulated or not.
tunnel source Set a source address for the tunnel. Syntax tunnel source {ip-address | ipv6–address | interface-type-number | anylocal} To delete the current tunnel source address, use the no tunnel source command. Parameters ip-address Enter the source IPv4 address in A.B.C.D format. ipv6–address Enter the source IPv6 address in X:X:X:X::X format. interface-typenumber • For a port channel interface, enter the keywords port-channel then a number from 1 to 128.
56 VLAN Stacking With the virtual local area network (VLAN)-stacking feature (also called stackable VLANs and QinQ), you can “stack” VLANs into one tunnel and switch them through the network transparently. The Dell Networking operating software supports this feature on Dell Networking OS. For more information about basic VLAN commands, refer to the Virtual LAN (VLAN) Commands section in the Layer 2 chapter.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced on the C-Series and S-Series. dei honor Honor the incoming DEI value by mapping it to an Dell Networking OS drop precedence. Enter the command once for 0 and once for 1. Syntax Parameters dei honor {0 | 1} {green | red | yellow} 0|1 Enter the bit value you want to map to a color.
dei mark Set the DEI value on egress according to the color currently assigned to the packet. S6000 Syntax dei mark {green | yellow} {0 | 1} Parameters 0|1 Enter the bit value you want to map to a color. green | red | yellow Choose a color: • Green: High priority packets that are the least preferred to be dropped. • Yellow: Lower priority packets that are treated as best-effort. Defaults All the packets on egress are marked with DEI 0.
• For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. Defaults Not configured. Command Modes CONF-IF-VLAN Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.
Usage Information WARNING: The following message displays to confirm the command: All non-default configurations on the related member ports ports () will be removed. Do you want to continue (y/n)? If you enter “y”, all non-default configurations on any member ports of the current stack group is removed when the unit is rebooted. vlan-stack access Specify a Layer 2 port or port channel as an access port to the stackable VLAN network.
To disable the Stackable VLAN feature on a VLAN, use the no vlan-stack compatible command. Defaults Not configured. Command Modes CONF-IF-VLAN Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
vlan-stack dot1p-mapping Map C-Tag dot1p values to a S-Tag dot1p value. You can separate the C-Tag values by commas and dashed ranges are permitted. Dynamic mode CoS overrides any Layer 2 QoS configuration in case of conflicts. Syntax vlan-stack dot1p-mapping c-tag-dot1p values sp-tag-dot1p value Parameters c-tag-dot1p value Enter the keyword c-tag-dot1p then the customer dot1p value that is mapped to a service provider do1p value. The range is from 0 to 7.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the E-Series ExaScale. C-Series and S-Series accept both bytes of the 2-byte S-Tag TPID. 8.2.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the C-Series and S-Series.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the E-Series ExaScale. C-Series and S-Series accept both bytes of the 2-byte S-Tag TPID. 7.8.1.0 Functionality augmented for C-Series and S-Series to enable multi-purpose use of the port. 7.7.1.0 Functionality augmented for E-Series to enable multi-purpose use of the port. 7.6.1.
! interface Vlan 20 no ip address tagged TenGigabitEthernet 1/42 shutdown Dell(conf-if-vl-20)#do show vlan Codes: * - Default VLAN, G - GVRP VLANs Q: U - Untagged, T - Tagged x - Dot1x untagged, X - Dot1x tagged G - GVRP tagged, M - Vlan-stack NUM Status Description * 1 Inactive 20 Active 100 Active Dell(conf-if-vl-20)# Example 2 Q Ports T Te 1/42 M Te 1/42 Dell(config)#vlan-stack protocol-type 88A8 Dell(config)#interface TenGigabitethernet 3/10 Dell(conf-if-te-3/10)#no shutdown Dell(conf-if-te-3/10)#swit
57 Virtual Routing and Forwarding (VRF) Virtual Routing and Forwarding (VRF) allows multiple instances of a routing table to co-exist on the same router at the same time. ip unknown-unicast Enable IPv4 catch-all route. S6000 Syntax ip unknown-unicast [vrf vrf-name] To remove the IPv4 catch-all route (0.0.0.0/0) from the LPM route forwarding table in hardware which gets added as a default configuration after the initialization of FIB Agent module, use the no ip unknownunicast command.
Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Introduced on the S4810, S4820T, S6000, and Z9000. All the default catch-all entries in the longest prefix match (LPM) table collect and transmit all unresolved IPv6 packets to the CPU, even if they are destined for unknown destinations. ip http vrf Configures an HTTP client with a VRF that is used to connect to the HTTP server.
Defaults None. Command Modes VRF MODE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9500. 9.4.(0.0) Introduced on the S-Series. Use this command to specify a descriptive name for a VRF.
VRF must be enabled prior to implementing this command. You can configure an IP subnet or address on a physical or VLAN interface that overlaps the same IP subnet or address configured on another interface only if the interfaces are assigned to different VRFs. If two interfaces are assigned to the same VRF, you cannot configure overlapping IP subnets or the same IP address on them.
Command History Usage Information Version Description 9.7(0.0) Introduced on the S4810, S4820T, S5000, S6000, S6000–ON, and Z9500. You can use the ip route-export tag command without specifying the route-map attribute to export all the routes corresponding to a source VRF. This action exposes source VRF's routes to various other VRFs, which then import these routes using the ip route-import tag command.
Usage Information It is possible to configure multiple import conditions per VRF depending on the exporting VRF. The export-target and import-target support only the match protocol and match prefix-list options. Other options that are configured in the route-maps are ignored. Related Commands ip route-export – exports routes to another VRF. ipv6 route-export Enables route leaking between VRFs. Exports or shares IPv6 routes corresponding to one VRF with other non-default VRFs.
ipv6 route-import Imports IPv6 routes that are leaked by another VRF using the tag specified by that VRF during export of these routes. Syntax ipv6 route-import tag [route-map-name] Parameters route-import Enter the keyword route-import to import IPv6 routes into the VRF. tag Enter a tag (ASN number) to specify an import route target for importing routes from another VRF.
Defaults N/A Command Modes ROUTE MAP MODE Command History Usage Information Version Description 9.7(0.0) Introduced on the S4810, S4820T, S5000, S6000, S6000–ON, and Z9500. You can specify the matching criteria only after defining a route-map. Before using this command, you must enter the route map mode using the route-map route-map-name command. The match criteria that you specify is associated with the route-map that you define.
To delete the association between a management port and a management VRF, use the no interface management command. Defaults None. Command Modes VRF MODE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON and Z9500. 9.4(0.0) Introduced on the S–Series. If the maximum route limit is not specified for a VRF, then it has unlimited space that extends to the maximum number of entries allowed for the system. This command is not applicable to the default and management VRFs. show ip vrf Displays information corresponding to the VRFs that are configured in the system.
FTOS#show ip vrf test1 VRF-Name VRF-ID Interfaces test1 1 Te 0/14,16-17 show run vrf Displays configuration information corresponding to all the VRFs in the system. Syntax show run vrf vrf-name Parameters Command Modes Command History vrf vrf-name • EXEC • EXEC Privilege Enter the keyword vrf and then the name of the VRF.. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
58 VLT Proxy Gateway The Virtual link trucking (VLT) proxy gateway feature allows a VLT domain to locally terminate and route L3 packets that are destined to a Layer 3 (L3) end point in another VLT domain. Enable the VLT proxy gateway using the link layer discover protocol (LLDP) method or the static configuration. For more information, refer to Dell Networking OS Command Line Reference Guide. proxy-gateway lldp Enables the proxy-gateway feature using LLDP protocol.
Command History Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Introduced on the S4810, S4820T, S6000, Z9000. Usage Information When proxy-gateway static configuration is added, the setting is saved in the Layer 2 module. When you remove the static proxy gateway configuration, each proxy-gateway static mac configured is deleted from the Layer 2 module.
peer-domain-link port-channel exclude-vlan Configure the VLT port channel, which is connected to remote VLT domain for Proxy Gateway and configure the VLANs that needs to be excluded from VLT Proxy Gateway. S6000 Syntax Parameters [no] peer-domain-link port-channel interface-identifier exclude-vlan vlanrange port-channel Configure the proxy-gateway interface port-channel. Port channel range is from 1 to 128. vlan-range Enter the VLAN IDs in which proxy gateway is not needed.
Command History Version Description 9.7(0.0) Introduced on the S6000-ON. 9.7(0.0) Removed the default value on the S-Series and Z-Series. 9.4(0.0) Introduced on the S4810, S4820T, S6000, Z9000, and MXL Switch. Usage Information When a VLT peer goes down, the local VLT node must stop sending its peer’s MAC address. If this timeout is configured, the local VLT node will send its peer's MAC address, till the timer expires. By default this timer value is infinity.
static Command Modes Display details about the static VLT proxy gateway configuration EXEC EXEC Privilege Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Introduced on the S4810, S4820T, S6000, and Z9000.
59 Virtual Link Trunking (VLT) Virtual link trunking (VLT) allows physical links between two chassis to appear as a single virtual link to the network core. VLT eliminates the requirement for Spanning Tree protocols by allowing link aggregation group (LAG) terminations on two separate distribution or core switches, and by supporting a loop-free topology.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 9.2(0.2) Added support for IPv6. 9.0.2.
Version Description 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. Example VLT ARP Statistics ---------------ARP Tunnel Pkts sent:0 ARP Tunnel Pkts Rcvd:0 ARP-sync Pkts Sent:0 ARP-sync Pkts Rcvd:0 ARP Reg Request sent:19 ARP Reg Request rcvd:10 Related Commands show vlt statistics — displays statistics on VLT operations.
Related Commands • after a VLT device is reloaded. • if the Peer VLT device was up at the time the VLTi link failed to the time when it was restored. show vlt statistics — displays statistics on VLT operations. delay-restore abort-threshold Increase the Boot Up timer to some value (>60 seconds). Syntax delay-restore abort-threshold To remove use the no delay-restore abort-threshold command. Defaults 60 seconds Command Modes VLT DOMAIN Command History This guide is platform-specific.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Added port-channel parameter on the S4810. 8.3.8.0 Introduced on the S4810.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 9.2(0.2) Introduced on the Z9000, S4810, and S4820T. 9.0.2.0 Introduced on the S6000. peer-link port-channel Configure the specified port channel as the chassis interconnect trunk between VLT peers in the domain.
peer-routing Enable L3 VLT peer-routing. This command is applicable for both IPV6/ IPV4. Syntax peer-routing To disable L3 VLT peer-routing, use the no peer-routing command. Defaults Disabled. Command Modes VLT DOMAIN (conf-vlt-domain) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Usage Information Version Description 9.2(0.2) Introduced on the Z9000, S4810, and S4820T. 9.0.2.0 Introduced on the S6000. When the timer expires, the software checks to see if the VLT peer is now available. If the VLT peer is not available, peer-routing is disabled on that peer. primary-priority Assign the priority for master election among VLT peers.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.8.0 Introduced on the S4810.
Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.8.0 Introduced on the S4810. Dell_VLTpeer1# show vlt backup-link VLT Backup Link ----------------Destination: Peer HeartBeat status: HeartBeat Timer Interval: HeartBeat Timeout: UDP Port: HeartBeat Messages Sent: HeartBeat Messages Received: 10.11.200.
Version Description 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. Usage Information If you do not add a parameter such as arp or mac, the output displays all of the counters.
Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.8.
(*, 225.1.1.2) Dell# VLAN 15 te 1/5 show vlt mismatch Display mismatches in VLT parameters. Syntax show vlt mismatch Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. Version The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.7(0.
PB for stp Enabled Disabled Vlan-type-config ---------------Codes:: P - Primary, C - Community, I - Isolated, N - Normal vlan, M Vlan-stack Vlan-ID ------- Local ----- 100 Peer ---- N M Port-type-config ---------------Codes:: p - PVLAN Promiscuous port, h - PVLAN Host port, t - PVLAN Trunk port, mt - Vlan-stack trunk port, mu - Vlan-stack access port, n Normal port Vlt Lag ------128 Local ----mt Peer ---mu Vlan-stack protocol-type -----------------------Local ----0x4100 Peer ---0x8100 VLT-VLAN
Example Dell#show vlt private-vlan vlan-id Codes: C- Community, I – Isolated, V – Internally tagged, T – tagged, * VLT Pvlan Primary Secondary ICL Status 10 V (*) 20(C) V 30 (I) V 40 50(C) 60 (I) T T T show vlt role Displays the VLT peer status, role of the local VLT switch, VLT system MAC address and system priority, and the MAC address and priority of the local VLT device. Syntax show vlt role Default Not configured. Command Modes EXEC Command History This guide is platform-specific.
Local System MAC address: 00:01:e8:8a:df:e6 Local System Role Priority: 32768 show vlt statistics Displays statistics on VLT operations. Syntax Parameters show vlt statistics [arp | domain | igmp-snoop | mac | multicast | ndp] domain Display the VLT statistics for the domain. multicast Display the VLT statistics for multicast. mac Display the VLT statistics for the MAC address. arp Display the VLT statistics for ARP. igmp-snoop Display the VLT statistics for IGMP snooping.
Version Mismatch Errors: Config Mismatch Errors: 0 0 VLT MAC Statistics ---------------L2 Info Pkts sent:6, L2 Mac-sync Pkts Sent:0 L2 Info Pkts Rcvd:3, L2 Mac-sync Pkts Rcvd:2 L2 Reg Request sent:1 L2 Reg Request rcvd:2 L2 Reg Response sent:1 L2 Reg Response rcvd:1 VLT Igmp-Snooping Statistics ------------------------------IGMP Info Pkts sent: 4 IGMP Info Pkts Rcvd: 1 IGMP Reg Request sent: 1 IGMP Reg Request rcvd: 2 IGMP Reg Response sent: 1 IGMP Reg Response rcvd: 1 IGMP PDU Tunnel Pkt sent: 5 IGMP PDU
The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.8.0 Introduced on the S4810. When you create a VLT domain on a switch, Dell Networking OS automatically assigns a unique unit ID (0 or 1) to each peer switch. The unit IDs are used for internal system operations. Use the unit-id command to explicitly configure the unit ID of a VLT peer. Configure a different unit ID (0 or 1) on each peer switch.
vlt-peer-lag port-channel Associate the port channel to the corresponding port channel in the VLT peer for the VLT connection to an attached device. Syntax Parameters vlt-peer-lag port-channel id-number id-number Enter the respective vlt port-channel number of the peer device. The range is from 1 to 128. Defaults Not configured. Command Modes INTERFACE PORT-CHANNEL Command History This guide is platform-specific.
60 Virtual Extensible LAN (VXLAN) Virtual Extensible LAN (VXLAN) is supported on Dell Networking OS. feature vxlan Enable VXLAN configuration globally on the platform. Syntax feature vxlan To disable the VXLAN, use the no feature vxlan command. Defaults Disabled Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. Version Description 9.7(0.
fail-mode Configures failure-mode on the platform. Syntax fail-mode secure To disable the fail-mode secure, use the no fail-mode securecommand. Parameters secure Enter the keyword secure to delete all its database and hardware flows/ resources, when the VTEP loses connectivity with the controller. Defaults non secure Command Modes VXLAN INSTANCE Command History This guide is platform-specific.
Related Commands feature vxlan — Enable VXLAN configuration globally on the platform. vxlan-instance (VAP) To configure a VXLAN-Access Port (VAP) in to VXLAN-instance Syntax vxlan-instance instance ID To unconfigure VAP, use the no vxlan-instance 1 command. Parameters instance ID Enter the VXLAN instance ID. The platform supports only the instance ID 1 in the initial release. Defaults Disabled Command Modes INTERFACE Command History This guide is platform-specific.
Usage Information The retry interval value caps at the value configured on the max-backoff. Related Commands vxlan-instance — Enable VXLAN Instance configuration on the platform. gateway-ip Configures gateway IP address on the platform. Syntax Parameters gateway-ip IP address IP address Enter the IP address of the gateway for the VXLAN instance. Defaults Disabled Command Modes VXLAN INSTANCE Command History This guide is platform-specific.
Command Modes VXLAN INSTANCE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Introduced on the S6000. vxlan-instance — Enable VXLAN instance configuration on the platform. show vxlan vxlan-instance Displays information related to Network Virtualization Overlay (NVO) Gateway.
show running-config vxlan Displays the VXLAN configuration information from running configuration. Syntax Command Modes Command History show running-config vxlan • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Introduced on the S6000.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Introduced on the S6000. Example Dell# show vxlan vxlan-instance <1> unicast-mac-remote Total Local Mac Count: 1 VNI MAC TUNNEL 4656 00:00:01:00:00:01 36.1.1.1 Related Commands vxlan-instance- Enable VXLAN Instance configuration on the platform.
4656 4656 Related Commands 00:00:02:00:03:03 00:00:02:00:03:04 Te 0/17 Te 0/17 0 0 vxlan-instance- Enable VXLAN Instance configuration on the platform. show vxlan vxlan-instance statistics interface Displays the port VLAN statistics information related to Network Virtualization Overlay (NVO) Gateway. Syntax Parameters Defaults Command Modes Command History Example show vxlan vxlan-instance instance ID statisitics interface interface instance ID Enter the VXLAN instance ID.
show vxlan vxlan-instance physical-locator Displays physical locators related to Network Virtualization Overlay (NVO) Gateway. Syntax show vxlan vxlan-instance instance ID physical—locator vtep-ip A.B.C.D Parameters instance ID Enter the VXLAN instance ID. The platform supports only the instance ID 1 in the initial release. A.B.C.D Enter the IP address of the VTEP. Defaults Disabled Command Modes VXLAN INSTANCE Command History This guide is platform-specific.
Example Version Description 9.4.(0.0) Introduced on the S6000. Dell#show vxlan vxlan-instance 1 logical-network Instance : 1 Total LN count : 1 Name bffc3be0-13e6-4745-9f6b-0bcbc5877f01 4656 VNID Dell#$n-instance 1 logical-network n 2a8d5d19-8845-4365-ad04-243f0b6df252 Name : 2a8d5d19-8845-4365-ad04-243f0b6df252 Description : Tunnel Key : 2 VFI : 28674 Unknown Multicast MAC Tunnels: 192.168.122.
Command History 1436 This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Introduced on the S6000.
61 Virtual Router Redundancy Protocol (VRRP) Virtual router redundancy protocol (VRRP) is supported by the Dell Networking operating system on Dell Networking OS. IPv4 VRRP Commands The following are IPv4 VRRP commands. advertise-interval Set the time interval between VRRP advertisements. Syntax advertise-interval {seconds | centisecs centisecs } To return to the default settings, use the no advertise-interval command. Parameters seconds Enter a number of seconds. The range is from 1 to 255.
Usage Information Dell Networking recommends keeping the default setting for this command. If you do change the time interval between VRRP advertisements on one router, change it on all routers. authentication-type Enable authentication of VRRP data exchanges. Syntax authentication-type simple [encryption-type] password To delete an authentication type and password, use the no authentication-type command. Parameters simple Enter the keyword simple to specify simple authentication.
Parameters vrrp-id (OPTIONAL) Enter the number of the VRRP group ID. The range is from 1 to 255. ipv6 (OPTIONAL) Enter the keyword ipv6 to clear counters from the IPv6 VRRP group. vrf vrf-name (OPTIONAL) Enter the keyword vrf and then the name of the VRF to clear counters that are maintained on the VRRP operations corresponding to that VRF. Command Modes EXEC Privilege Command History This guide is platform-specific.
• For a VLAN interface, enter the keyword vlan then the VLAN ID. The VLAN ID range is from 1 to 4094. vrrp-id (OPTIONAL) Enter a number from 1 to 255 as the VRRP group ID. all Enter the keyword all to enable debugging of all VRRP groups. bfd Enter the keyword bfd to enable debugging of VRRP BFD interactions. database Enter the keyword database to enable debugging of configuration changes. interface Enter the keyword interface to enable debugging of interface state changes..
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. disable Disable a VRRP group. Syntax disable To re-enable a disabled VRRP group, use the no disable command.
To return to the default value, use the no hold-time command. Parameters seconds Enter the number of seconds. The range is from 0 to 65535. The default is zero (0) seconds. centisecs centisecs Enter the keyword centisecs then the number of centisecs in units of 25 centisecs . The range is from 0 to 65525 in units of 25 centisecs. Defaults zero (0) seconds or or (0) centiseconds Command Modes VRRP Command History This guide is platform-specific.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. priority Specify a VRRP priority value for the VRRP group. The VRRP protocol uses this value during the MASTER election process.
If you set the priority command to 255 and the virtual-address is not equal to the interface’s primary IP address, an error message appears. show config View the non-default VRRP configuration. Syntax show config [verbose] Parameters verbose (OPTIONAL) Enter the keyword verbose to view all VRRP group configuration information, including defaults. Command Modes VRRP Command History This guide is platform-specific.
Command Modes Command History • For Port Channel interface types, enter the keywords port-channel then the number. The 128. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot • For a VLAN interface, enter the keyword vlan then the VLAN ID. The VLAN ID range is from brief (OPTIONAL) Enter the keyword brief to view a table of information on the VRRP groups. ipv6 (OPTIONAL) Enter the keyword ipv6 to view only VRRP IPv6 groups.
Item Description Master addr Displays the IP address of the MASTER router. Virtual addr(s) Displays the virtual IP addresses of the VRRP routers associated with the interface. Example (Brief) Dell>Interface Grp Pri Pre State Master addr Virtual addr(s) Description-----------------------------------------------------------Te 1/37 1 100 Y Master 200.200.200.200 200.200.200.201 Te 1/37 2 100 Y Master 200.200.200.200 200.200.200.202 200.200.200.203 Description Te 1/37 3 100 Y Master 1.1.1.1 1.1.1.
State: Master, Priority: 105, Master: 10.1.1.253 (local) Hold Down: 0 sec, Preempt: TRUE, AdvInt: 1 sec Adv rcvd: 0, Adv sent: 1862, Gratuitous ARP sent: 0 Virtual MAC address: 00:00:5e:00:01:01 Virtual IP address: 10.1.1.252 Authentication: (none) Tracking states for 1 interfaces: Up TenGigabitEthernet 1/17 priority-cost 10 -----------------TenGigabitEthernet 1/4, VRID: 2, Net: 10.1.2.253 State: Master, Priority: 110, Master: 10.1.2.
• priority-cost Defaults priority cost = 10 Command Modes VRRP Command History Usage Information For a VLAN interface, enter the keyword vlan followed by the VLAN ID. The VLAN ID range is from 1 to 4094. (OPTIONAL) Enter a number as the amount to be subtracted from the priority value. The range is 1 to 254. The default is 10. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 7.6.1.0 Introduced on the S-Series (S50 only). 7.5.1.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Introduced support for telnetting to the VRRP group IP address assigned using this command. 6.2.1.1 Introduced on the E-Series. The VRRP group only becomes active and sends VRRP packets when a virtual IP address is configured. When you delete the virtual address, the VRRP group stops sending VRRP packets.
• Related Command When an interface comes up, whether as part of a system reload or an interface reload, the system waits 300 seconds (5 minutes) to bring up VRRP on that interface. vrrp delay reload — sets the delay time for VRRP initialization after a system reboot. vrrp delay reload Set the delay time for VRRP initialization after a system reboot. Syntax vrrp delay reload seconds Parameters seconds Enter the number of seconds for the delay. The range is from 0 to 900 (0 indicates no delay).
Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
Usage Information Version Description 9.5(0.0) Introduced on the Z9000, S6000, S4820T, S4810, and MXL. You can use the version both command to migrate from VRRPv2 to VRRPv3. When you set the VRRP protocol version to both, the switch sends only VRRPv3 advertisements but can receive either VRRPv2 or VRRPv3 packets. To migrate an IPv4 VRRP group from VRRPv2 to VRRPv3: 1. Set the switches with the lowest priority to “both”. 2. Set the switch with the highest priority to version to 3. 3.
vrf vrf-name (OPTIONAL) Enter the name of a VRF instance (32 characters maximum) to clear the counters of all IPv6 VRRP groups in the specified VRF. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 8.3.19.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 8.3.19.0 Introduced on the S4820T. 8.3.10.0 Introduced on the S4810. 8.4.1.0 Introduced on E-Series ExaScale, C-Series, and S-Series. Support was added for IPv6 VRRP groups in non-default VRF instances. 8.3.2.0 Introduced on the E-Series TeraScale. If no options are specified, debug is active on all interfaces and all VRRP groups. show vrrp ipv6 View the IPv6 VRRP groups that are active.
Usage Information The following describes the show vrrp ipv6 command shown in the following example. Line Beginning with Description GigabitEthernet... Displays the Interface, the VRRP group ID, and the network address. If the interface is no sending VRRP packets, 0.0.0.0 appears as the network address. VRF VRF instance to which the interface (on which the VRRP group is configured) belongs. State: master... Displays the interface’s state: • Na/If (not available).
Virtual IP address: 1::255 fe80::255 vrrp-ipv6-group Assign an interface to a VRRP group. Syntax vrrp-ipv6-group vrid Parameters vrid Enter the virtual-router ID number of the VRRP group. The VRID range is from 1 to 255. Defaults Not configured. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.