Reference Guide
34 | Management
www.dell.com | support.dell.com
To change the severity level of messages logged to a syslog server, use the following command in the
CONFIGURATION mode:
To view the logging configuration, use the
sshow running-config logging Command in the EXEC privilege
mode.
Display the Logging Buffer and the Logging Configuration
Display the current contents of the logging buffer and the logging settings for the system, use the show
logging Command in the EXEC privilege mode.
show logging Command
FTOS#show logging
syslog logging: enabled
Console logging: level Debugging
Monitor logging: level Debugging
Buffer logging: level Debugging, 40 Messages Logged, Size (40960 bytes)
Trap logging: level Informational
00:00:24: %S6000:0 %IFAGT-5-INSERT_OPTICS_QSFP: Optics QSFP inserted in slot 0 port 68
00:00:24: %S6000:0 %IFAGT-5-INSERT_OPTICS_QSFP: Optics QSFP inserted in slot 0 port 4
00:00:22: %STKUNIT0-M:CP %IFMGR-5-OSTATE_UP: Changed interface state to up: Te 0/0
00:00:21: %STKUNIT0-M:CP %SNMP-6-SNMP_COLD_START: Agent Initialized - SNMP COLD_START.
00:00:21: %STKUNIT0-M:CP %CONFD_MGR-5-CONFD_STARTUP: ConfD is ready
00:00:21: %STKUNIT0-M:CP %SEC-5-LOGIN_SUCCESS: Login successful on console
00:00:20: %STKUNIT0-M:CP %SNMP-6-SNMP_V3_FIPS: SNMPv3 FIPS Disabled.
00:00:20: %STKUNIT0-M:CP %IFMGR-5-ASTATE_UP: Changed interface Admin state to up: Te 0/0
00:00:20: %STKUNIT0-M:CP %SYS-5-CONFIG_LOAD: Loading configuration file
00:00:19: %STKUNIT0-M:CP %CHMGR-5-PSU_FAN_STATUS: Fan 0 in PSU 0 of Unit 0 is up
00:00:19: %STKUNIT0-M:CP %CHMGR-5-FANTRAY_INSERTED: Fan tray 2 of Unit 0 is inserted
00:00:18: %STKUNIT0-M:CP %CHMGR-2-FAN_BAD: Minor alarm: 1 out of 2 fans in fantray 1 of unit 0 are down
00:00:18: %STKUNIT0-M:CP %CHMGR-5-FANTRAY_INSERTED: Fan tray 1 of Unit 0 is inserted
00:00:18: %S6000:0 %CHMGR-2-PSU_FAN_SPEED_CHANGE: PSU_Fan speed changed to 100 % of the full speed
00:00:18: %S6000:0 %CHMGR-2-FAN_SPEED_CHANGE: Fan speed changed to 100 % of the full speed
00:00:18: %STKUNIT0-M:CP %CHMGR-1-PSU_AIRFLOW_COMBO_MISMATCH: Major alarm: PSU - FAN airflow inter
mismatch detected in unit 0
00:00:18: %STKUNIT0-M:CP %CHMGR-5-FANTRAY_INSERTED: Fan tray 0 of Unit 0 is inserted
00:00:18: %S6000:0 %CHMGR-2-PSU_FAN_SPEED_CHANGE: PSU_Fan speed changed to 40 % of the full speed
00:00:18: %S6000:0 %CHMGR-2-FAN_SPEED_CHANGE: Fan speed changed to 40 % of the full speed
00:00:17: %STKUNIT0-M:CP %CHMGR-5-PEM_REMOVED: Minor Alarm:Power entry module 1 of unit 0 is absent
00:00:17: %STKUNIT0-M:CP %CHMGR-0-PS_UP: Power supply 0 in unit 0 is up
00:00:17: %STKUNIT0-M:CP %CHMGR-5-PEM_INSERTED: Power entry module 0 of unit 0 is inserted
00:00:16: %STKUNIT0-M:CP %IFMGR-5-OSTATE_UP: Changed interface state to up: Ma 0/0
00:00:16: %STKUNIT0-M:CP %RAM-5-STACK_STATE: Stack unit 0 is in Active State.
00:00:16: %STKUNIT0-M:CP %CHMGR-5-SYSTEM_READY: System ready
00:00:16: %STKUNIT0-M:CP %CONFD_MGR-5-CONFD_STARTUP: ConfD startup succeeded in phase2
00:00:15: %STKUNIT0-M:CP %CHMGR-5-STACKUNITUP: Stack unit 0 is up
00:00:15: %STKUNIT0-M:CP %CHMGR-5-CHECKIN: Checkin from Stack unit 0 (type S6000, 128 ports)
00:00:15: %STKUNIT0-M:CP %CONFD_MGR-5-CONFD_STARTUP: ConfD startup succeeded in phase1
00:00:14: %STKUNIT0-M:CP %CONFD_MGR-5-CONFD_STARTUP: ConfD startup succeeded in phase0
00:00:14: %S6000:0 %POLLMGR-2-USER_FLASH_STATE: USB flash disk missing in 'usbflash:'
00:00:11: %STKUNIT0-M:CP %CHMGR-5-STACKUNITDETECTED: Stack unit 0 present
00:00:09: %STKUNIT0-M:CP %RAM-6-ELECTION_ROLE: Stack unit 0 is transitioning to Management unit.
To view any changes made, use the show running-config logging Command in the EXEC privilege mode.