Reference Guide
386 | Interfaces
www.dell.com | support.dell.com
Commas
The example below shows how to use commas to add different interface types to the range, enabling all
Tengigabit Ethernet interfaces in the range 5/1 to 5/23 and both Ten Gigabit Ethernet interfaces 1/1 and 1/
2.
Figure 20-21. Multiple-Range Bulk Configuration Tengigabit Ethernet and Ten-Gigabit Ethernet
Add ranges
The example below shows how to use commas to add VLAN and port-channel interfaces to the range.
Figure 20-22. Multiple-Range Bulk Configuration with VLAN, and Port-channel
Interface Range Macros
The user can define an interface-range macro to automatically select a range of interfaces for
configuration. Before you can use the macro keyword in the interface-range macro command string, you
must define the macro.
To define an interface-range macro, enter this command:
Command Syntax Command Mode Purpose
FTOS (config)# define interface-range macro_name {vlan
vlan_ID - vlan_ID} | {{Tengigabitethernet |
tengigabitethernet | fortyGigE} slot / interface - interface} [
{vlan vlan_ID - vlan_ID} {{Tengigabitethernet |
tengigabitethernet | fortyGigE} slot/interface - interface}]
CONFIGURATION Defines the interface-range
macro and saves it in the
running configuration file.
FTOS(config-if)# interface range Tengigabitethernet 5/1 - 23 , tengigabitethernet 1/1 - 2
FTOS(config-if-range-te-5/1-23)# no shutdown
FTOS(config-if-range-te-5/1-23)#
FTOS(config-ifrange-te-5/1-23-te-1/1-2)# interface range Vlan 2 – 100 , Port 1 – 25
FTOS(config-if-range-te-5/1-23-te-1/1-2-so-5/1-vl-2-100-po-1-25)# no shutdown
FTOS(config-if-range)#