Reference Guide

Data Center Bridging (DCB) | 309
Figure 15-13. show stack-unit all stack-ports all ets details Command Example
Troubleshooting PFC, ETS, and DCBx Operation
DCBx Oper Status is Down
In the show interfaces pfc | ets | dcbx output, the DCBx operational status may be down for any of the
reasons described in Table 15-6. When DCBx is down, the following values display in the show output
field for DCBx Oper status:
PFC DCBx Oper status: Down
ETS DCBx Oper status: Down
FTOS(conf)# show stack-unit all stack-ports all ets details
Stack unit 0 stack port all
Max Supported TC Groups is 4
Number of Traffic Classes is 1
Admin mode is on
Admin Parameters:
--------------------
Admin is enabled
TC-grp Priority# Bandwidth TSA
------------------------------------------------
0 0,1,2,3,4,5,6,7 100% ETS
1 - -
2 - -
3 - -
4 - -
5 - -
6 - -
7 - -
8 - -
Stack unit 1 stack port all
Max Supported TC Groups is 4
Number of Traffic Classes is 1
Admin mode is on
Admin Parameters:
--------------------
Admin is enabled
TC-grp Priority# Bandwidth TSA
------------------------------------------------
0 0,1,2,3,4,5,6,7 100% ETS
1 - -
2 - -
3 - -
4 - -
5 - -
6 - -
7 - -
8 - -